posttreatment

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 2 more files in changeset.
DEN-16924: Remove QR Code for P1

- Added back the visible false for the both QR codes on the both treatment confirm/review screens.

  1. … 1 more file in changeset.
DEN-16924: Remove QR Code for P1

- Added back the visible false for the both QR codes on the both treatment confirm/review screens.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 31 more files in changeset.
CS-5: @ UI: TxCode generation on device

- The Qr code were removed from the PreTreatmentConfirm.qml and the PostTreatmentReview.qml for P1, and now has been decided to use it.

- The vital count down which was removed for the P1 put back.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 610 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 610 more files in changeset.
DENBUG-75: UI: Treatment log data via USB does not match with data displayed on the Treatment Review Screen

CS-5: @ UI: TxCode generation on device

~ Added QRCode for the TxCode

- Added a Third-Party Open-Source MIT Licence QRCode generator from the following link:

* Copyright (c) Project Nayuki. (MIT License)

* https://www.nayuki.io/page/qr-code-generator-library

- Created a QRCode component

- Added the QRCode generation functionality in the GuiView

- Added QRCode for both the Pre-Tx-Confirmation (UI Generated) and Post-Tx-Review (CS received)

- Moved the CS TxCode Receive wait "..." from C++ to QML to keep the TxCode empty while wait to avoid displaying the "..." as a QRCode.

- Animated the CS TxCode Receive wait "..."

~ Added development testability for the CloudSync communication

~ Fixed the date change buf file watch to wait for the CS to get the checkin and create the out buf file.

CS-3: CS: Heparin OFF o the HCP portal Treatment report

- Fixed some issues in the create treatment screen on heparin type

- Combined the separated values for log and GUI into one values for both.

- Added the functionality for the TreatmentConfirm (Pre-Tx), TreatmentReview (Ppost-Tx), TreatmentReport (log) for the heparin values.

DENBUG-75: UI: Treatment log data via USB does not match with data displayed on the Treatment Review Screen

DENBUG-75: UI: Treatment log data via USB does not match with data displayed on the Treatment Review Screen

- removed the qtcode component from the two screen of the treatment confirm, review for P1 release.

  1. … 19 more files in changeset.
CS-5: @ UI: TxCode generation on device

~ Added QRCode for the TxCode

- Added a Third-Party Open-Source MIT Licence QRCode generator from the following link:

* Copyright (c) Project Nayuki. (MIT License)

* https://www.nayuki.io/page/qr-code-generator-library

- Created a QRCode component

- Added the QRCode generation functionality in the GuiView

- Added QRCode for both the Pre-Tx-Confirmation (UI Generated) and Post-Tx-Review (CS received)

- Moved the CS TxCode Receive wait "..." from C++ to QML to keep the TxCode empty while wait to avoid displaying the "..." as a QRCode.

- Animated the CS TxCode Receive wait "..."

~ Added development testability for the CloudSync communication

~ Fixed the date change buf file watch to wait for the CS to get the checkin and create the out buf file.

  1. … 12 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 20 more files in changeset.
DEN-14815: Cartridge Removal Screen is Displayed Prematurely

- Added the QML code.

DEN-14815: Cartridge Removal Screen is Displayed Prematurely

- Added the message ID_AdjustPatientDisconnectionConfirmReq = 0x0600, // 6

  1. … 9 more files in changeset.
DEN-15911: Post-treatment screen displays heparin type and heparin concentration even if heparin rate and dispensing were disabled in pre-treatment

- Separated the Log and the Gui values for now to address the cloud log later, when the cloud is ready to not to reject Logs to have NONE.

  1. … 8 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 50 more files in changeset.
DEN-14584: CloudSync Retry

- Implemented the TxReport peending

- Added TxCode to the TxReport

  1. … 8 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 606 more files in changeset.
DEN-14391 , DEN-14393 : Qt 5.15.10 [QML run-time issues]

- Fixed all the QML warning and errors

- Enabled the Clang-Tidy, Clazy and cppcheck and fixed some.

- Removed unused images

- made the Denali POST logo transparent.

  1. … 56 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 95 more files in changeset.
Merge branch 'DEN-13198-UI_BN_75' into staging

  1. … 45 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 99 more files in changeset.
DEN-13645 IMP: DEN-12958: UI shall generate the POST fail alarm if the SD-Card not present and stop logging

__________

- Log Export

- Added the Alarm generation on the GuiController if SD-Card is not ready, or is/becomes read-only.

- AlarmGenerator

- Added the SD-Card failure alarm - ALARM_ID_UI_POST_FAILURE_SDCARD

- Added alarm clear - ALARM_ID_NO_ALARM

- Added a flag to stop logging if the SD-Card is not ready or is readonly.

- Removed pause on log clean up.

- Improved the DeviceController SD-Card, USB status detection.

- Fixed and improved the MVC connection betweein device/Application/Gui controllers.

- A CLI switch ( -S ) added to disable the feature that is disabling the log if the SD-Card doesn't exist. So if the -S switch is used while calling the denali application, the logging will NOT be disabled, if SD-Card fails.

- In the ExportButton and USBButton(eject) removed the enable logic and has to be done outside of the component. It has been done for the Settings/export and Post-Tx/Review.

- Added title and file count for each SD-Card and USB-Drive panels.

__________

- Run.sh

- Added a check for the CloudSync and if the folder doesn't exist it won't do the rest

- Kill the denali application, in case it is still running.

- Added SD-Card type as part of its detection and if it is not ext4 format it fails the test.

- Optimized the mount point detection.

__________

- NoCANBus

- added the NoCANBus to the fault and init modes to not to navigate to those if NoCANBus is true. Otherwise it conflict with navigate to the home.

- Added a log in case the NoCANBus is enabled.

__________

- Settings

- Converted the '\n' in the settings values to actual newline character.

__________

- Thread:

- Moved the QuiController in its own thread, _Gui_Thread.

__________

- Alarms

- Added an emit to update the Alarm Dialog with the latest title/message, received from Alarms.conf In case there was an alarm before even Alarm.conf is read.

  1. … 27 more files in changeset.
DEN-13645: IMP: General Implementation

DEN-12836: Treatment Report/log export modifications

- Finalizing the log export.

  1. … 4 more files in changeset.
DEN-13134: IMP: General Implementation for any bugs and any other implementations

DEN-12836: Treatment Report/log export modifications

- Improved the SDItem and renamed to SDCProgressItem.

- Added another separate progress circle component for the USB Driver [USBProgressItem]

- Adding Space check for USB as well to get the USBProgressCircle update.

- Optimized ExportButton and added two size for Settings screen(normal) and Treatment Review screen(small)

- Improved USB button comonent

- Added a global byte size converter in Variable.qml

- Improved MainMenu component

- Added a notification for the TreatmentFlowBase.qml main component.

- Used the notification of the TreatmentFlowBase.qml for the Treatment Review Screen Log export to display feedback to the user.

- Added an individual screen for the log export.

- Removed the Export Log and USB eject from the main settings option screen.

- Added an option for the Export log on the settings home screen which is currently enabled for non-service users too.

- Fixed the DGVersionResponse, log message.

- Put a comment in the FileHandler.cpp about the Qt API QStorageInfo::mountedVolume() which seems so slow on detecting mounted volumes when a USB derive is just plugged in (It could be system issue, since it has also been observed from shell console.)

- Added error handling to the Treatment Log/Report export

DEN-12726: Denali application crashing

- Modified the Logger Maxusage limit to keep 50% of the data/event log and 15% of the service log and keep 35% free, after the log clean up triggered by 15% free storage detected.

DEN-13051: Encounter alarm 6 and SD card detection problem after updating UI version

DEN-13156: Settings screen menu should disappear on service mode

- Improved the MainStack.qml navigation rules.

- Improved the Patient ID keyboard handling, to hide the keyboard, when not on the screen.

- Improved the SettingsStack.qml navigation rules.

DEN-13128: KBM: Cloud Sync Integration

- Saving the CS log in UTC timezone.

DEN-13127: LTS: Development Support

- Fixed the issue found on the End-Treatment screen Confirm button which didn't respect the last instruction page enable only rule.

  1. … 44 more files in changeset.
DEN-12836: Treatment Report/log export modifications

- DEN-12944: KBM: Usual Meetings/Support/Development

- Modified the setup.sh script to work on PDT (Pacific timezone)

- Added timezone display on the screen by adding it to the VDateTime

- Removed unnecessary FileHandler header include.

- Modified the Treatment Review Export button to export the current TxReport only.

- Added the Safe Eject button for the Post-Treatment TxReport Export.

- Moved Log Folder definitions to the StorageGlobal.

- Fixed the greeting issue [https://github.com/Diality/testsuites/issues/57]

- DEN-11826: Bluetooth BloodPressure Cuff Interval - Observation

- It has completely redesigned

- DEN-9706: Blood Pressure measurement entry window closes automatically

- Auto Hide is disabled

  1. … 25 more files in changeset.
wrapping up multiple sprint codes

- LOG: Added a CLI option to disable the Check-In logs by adding -k, --disable-check-in-log at the CLI. This was interrupting the log tests. The build macro has been removed.

- POST: During the coverage find out that the getter functions have not even been called in the ApplicationPost.

- CloudSync: Added the Treatment Code(TxCode), received from the cloud after the Treatment Report stored by Cloud System. It is a message communication between UI<=(2008)=CS.

- CloudSync: Two error added for the 2008: TxCode

- CloudSync: Due to some issues on Cloud System regarding the credential expiration, It has been asked to add a temporary workaround to send the credentials (1004) before message 1006:Device State, 1007:Treatment Report.

- DEN-12727: Treatment Parameter Screen: Added more space between the parameters components specially the Temperature slider and the option on top.

- DEN-12829: Enabled the back button on the Start Treatment Screen

- DEN-12761: Enabled an empty Patient ID.

It has not yet been implemented on the CloudSync App, so if sent empty CloudSystem will later reject to store the TxReport.

When later implemented an unassigned random Patient ID will be created for that TxReport to be later defined and assigned.

- DEN-12837, DEN-12840: The Disinfection Scheduling Entry and the Confirm button have been removed from the "Dialysate Generator Settings" screen.

- DEN-12837, DEN-12840: The "Dialysate Generator Settings" changed to "DG Cleaning" for the menu option and the screen title.

- Settings: The Clear Alarm Condition button has been removed from the settings screen for the release.

- Settings: The options which has no implementation for the phase 1 have been removed from the Settings screen Service mode options. [Language, Calibration, SW Update, Factory Reset]

- DEN-12841: Reworded the password entries in Service screen and for WiFi Join Screen.

- TxCode, TxReport: removed the commented out Treatment Report Parameters from the code.

- LOG: added one character space int he DEBUG log for the Not Enough Data in Types.

- Settings: The Service Dates default values changed from 0 to "" since they are strings.

- Settings: Added some clarification for the Home screen greetings

  1. … 32 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 159 more files in changeset.
DEN-11812 UI Keyboard displays text on the spacebar and has a wink emoji button

- added the keyboard layout and style to remove some buttons and remove the text on the spacebar.

- added DEBUG_DISABLE_MAXIMIZE, due to touch screen issue on some devices, the maximized alarm can't be minimized to see the screen underneath.

- While fixing some issues in the Dialin/Simulator, added the reject reason notification to the Treatment review screen and cleared the values on rejection.

- update the Dialysate Temperature max to the 37 from 38.

  1. … 40 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 76 more files in changeset.
DEN-10153: Treatment Log Comments Investigations

- Fixed the Treatment Review overlapped items.

  1. … 3 more files in changeset.
DEN-12180: Internal general support

- investigate on the Begin Prime back to Cartridge installation

- Added objectName for easier debug.

- added the stack change for the Cartridge Installation in case FW wants to navigate back from Begin Prime to the beginning of Cartridge Installation.

  1. … 5 more files in changeset.