PreTreatmentConnectionStack.qml

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 13 more files in changeset.
DEN-16693: Institutional Settings Implementation

- The Ultrafiltration slide is an old slider so added some functionality in the code.

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 612 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 612 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 4 more files in changeset.
DEN-11827: Updated - BP/HR screen missing a way to pair bluetooth cuff

Modify to use page() to add/remove the bt settings screen

DEN-13789 : Changed - Change Request: UI allows user to continue into treatment with a diastolic pressure greater than the systolic pressure

Remove "Skip" label logic

Set confirm button to rely on the valid state of bp/hr entry

add inclusion to the valid values for diasystolic and systolic pressures

  1. … 1 more file in changeset.
DEN-11827 : Changed - BP/HR screen missing a way to pair bluetooth cuff

Based on Behrouz' comments, changed button text, visibility logic, and instruction-text

modify the clearing of pairedAddr to avoid flickering of the CONNECTION button on bp/hr screen

  1. … 1 more file in changeset.
DEN-15287 : Added - BP/HR screen missing a way to pair bluetooth cuff

Added the button to access bluetooth screen from bp/hr screen

Add bluetooth settings screen component in bp/hr screen

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 13 more files in changeset.
DEN-15331 : Fixed - Usability: UI: Perform BP measurement Prior to UF volume

Update work flow so BP/HR is done before UF volume

    • -14
    • +14
    ./PreTreatmentConnectionStack.qml
  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 608 more files in changeset.
DEN-14391 , DEN-14393 : Qt 5.15.10 [QML run-time issues]

- Fixed all the QML warning and errors

- Enabled the Clang-Tidy, Clazy and cppcheck and fixed some.

- Removed unused images

- made the Denali POST logo transparent.

    • -12
    • +12
    ./PreTreatmentConnectionStack.qml
  1. … 56 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 100 more files in changeset.
DEN-12836: Treatment Report/log export modifications

- DEN-12944: KBM: Usual Meetings/Support/Development

- Modified the setup.sh script to work on PDT (Pacific timezone)

- Added timezone display on the screen by adding it to the VDateTime

- Removed unnecessary FileHandler header include.

- Modified the Treatment Review Export button to export the current TxReport only.

- Added the Safe Eject button for the Post-Treatment TxReport Export.

- Moved Log Folder definitions to the StorageGlobal.

- Fixed the greeting issue [https://github.com/Diality/testsuites/issues/57]

- DEN-11826: Bluetooth BloodPressure Cuff Interval - Observation

- It has completely redesigned

- DEN-9706: Blood Pressure measurement entry window closes automatically

- Auto Hide is disabled

  1. … 26 more files in changeset.
wrapping up multiple sprint codes

- LOG: Added a CLI option to disable the Check-In logs by adding -k, --disable-check-in-log at the CLI. This was interrupting the log tests. The build macro has been removed.

- POST: During the coverage find out that the getter functions have not even been called in the ApplicationPost.

- CloudSync: Added the Treatment Code(TxCode), received from the cloud after the Treatment Report stored by Cloud System. It is a message communication between UI<=(2008)=CS.

- CloudSync: Two error added for the 2008: TxCode

- CloudSync: Due to some issues on Cloud System regarding the credential expiration, It has been asked to add a temporary workaround to send the credentials (1004) before message 1006:Device State, 1007:Treatment Report.

- DEN-12727: Treatment Parameter Screen: Added more space between the parameters components specially the Temperature slider and the option on top.

- DEN-12829: Enabled the back button on the Start Treatment Screen

- DEN-12761: Enabled an empty Patient ID.

It has not yet been implemented on the CloudSync App, so if sent empty CloudSystem will later reject to store the TxReport.

When later implemented an unassigned random Patient ID will be created for that TxReport to be later defined and assigned.

- DEN-12837, DEN-12840: The Disinfection Scheduling Entry and the Confirm button have been removed from the "Dialysate Generator Settings" screen.

- DEN-12837, DEN-12840: The "Dialysate Generator Settings" changed to "DG Cleaning" for the menu option and the screen title.

- Settings: The Clear Alarm Condition button has been removed from the settings screen for the release.

- Settings: The options which has no implementation for the phase 1 have been removed from the Settings screen Service mode options. [Language, Calibration, SW Update, Factory Reset]

- DEN-12841: Reworded the password entries in Service screen and for WiFi Join Screen.

- TxCode, TxReport: removed the commented out Treatment Report Parameters from the code.

- LOG: added one character space int he DEBUG log for the Not Enough Data in Types.

- Settings: The Service Dates default values changed from 0 to "" since they are strings.

- Settings: Added some clarification for the Home screen greetings

  1. … 32 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 584 more files in changeset.
Merge branch 'UI_BUG_S62' into develop

DEN-11825: BP/HR screen has no instruction for user to read from bluetooth cuff or enter information

- Center aligned the notification

  1. … 1 more file in changeset.
Merge branch 'UI_BUG_S62' into develop

DEN-8145: Issues with UI Create Treatment screen

Remainder items (summary):

- 3) Discuss whether to keep the manufacturing default on the slider since the user needs to confirm each parameter: Agreed to set to the minimum value

- 7) Arterial Pressure and Venous Pressure should be consistent with other parameters, the unit should be shown at the end: will be updated to have the units located in the title of the slider.

- Also fixed the title coloring when the slider has not been adjusted yet.

  1. … 4 more files in changeset.
DEN-11825: BP/HR screen has no instruction

- Added the suggested on line instruction for the user.

Merge branch 'UI_BUG_S62' into develop

  1. … 3 more files in changeset.
DEN-9704: Missing acknowledgement confirmation message/alarm when leaving BP/HR blank

- Added a script to later be used for the log export on the device, but it now only works on the VM since the device doesn't have the zip tool.

- Added a mimic function to simulate the BCuff measurement received and assigned F11 to it and it will only be enabled if the macro DEBUG_BCUFF_MIMIC is defined.

- Added opened and closed signals to the EntryDialog.qml to make it do the auto focus on the firstInput object when opened.

- Added setFocus() function in the BPHREntry.qml

- Removed the enabled option from doReset of the VTreatmentVitals

- And created two separate enableDialog for vital entry, and enable update for the auto update the properties.

- Added a constructor with systolic, diastolic, heartRate parameter to set the data on creation to be used in the message mimic.

- Added systolic, diastolic, heartRate parameters to the doTrigger of the VCommonAdjustmentVitals to open the vitals entry dialog with default values.

  1. … 15 more files in changeset.
DEN-10205: BCuff [Missing Feature]: Try to reconnect to the previously paired

Bluetooth Code improvements:

- stopping the agent from scanning if user selects a device to connect.

- Rewording of the parred device not found

- Added "ZERO" check for the address

- Added real-time Bluetooth status on top of the main screen.

- Not The UI will always updated but the TreatmentLog still needs UI to be in a proper screen/state to log the Vitals measurements.

Other Requested modifications:

Chris.Y:

- Added back for the pre-treatment BP/HR screen to the Ultrafiltration screen.

Eliza.P:

- Added notification for the Heparin Dispensing:"Heparin Active"

- Changed the button text to "OFF" when the heparin is off.

- Changed the button text to "COMPLETE" when the heparin is complete.

- Shortened the notification text and removed the "Heparin ... " from the beginning.

- Won't show the off notification since the button text changed to imply that.

  1. … 10 more files in changeset.
DEN-9637: Update Design Documents

- Added the ability to enable/disable the vitals measurement logs [it's still unknown that how to stop in case of the treatment ended by alarm or system fault.]

- Added the Battery Level of the selected device.

  1. … 18 more files in changeset.
DEN-8920 Implementation [Store Collected Data]

- Added MVC

- Added the TxLog and Log_Events and so...

- Added the timeout/interval

- ....

  1. … 14 more files in changeset.
DEN-8918: BtC: Implementation [Screens] & DEN-8919: BtC: Implementation [Navigations]

- The view needs to be implemented in C++.

  1. … 18 more files in changeset.
DEN-7377: preTx: Implementation [Dynamic Instruction Loading] ( 2 )

DEN-7457: Meetings & Support - General purpose

  1. … 51 more files in changeset.
DEN-7408: Code improvement for navigation

- added vCondition to the page function for the stack item to pass the state property value.

- added fault , service and initial placeholder pages.

  1. … 14 more files in changeset.