Merge branch 'DEN-14197-sw-s83-mg-pi-optimizations' into develop

DEN-14197: Created a set pwm step limit for PI controllers. Updated RO pump profiles to contain a max set step limit. Removed unused #defines for ro pump.

  1. … 2 more files in changeset.
DEN-14197: Created a set pwm step limit for PI controllers. Updated RO pump profiles to contain a max set step limit. Removed unused defines for ro pump.

  1. … 2 more files in changeset.
Merged DEN-14307

  1. … 1 more file in changeset.
DEN-14307 updated the code and updated the checkAlarms.sh to check the alarms manual table upon compilation

  1. … 5 more files in changeset.
DG-DEN-14197_SW S83 MG PI Optimizations
DG-DEN-14197_SW S83 MG PI Optimizations
Fixed merge conflicts.

  1. … 8 more files in changeset.
DEN-14197: Removed RO pump ramp state. Tuned RO pump control coefficients.

DG-DEN-14307_DG HD Dev HD DG Dvt Update Part 6
DG-DEN-14307_DG HD Dev HD DG Dvt Update Part 6
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 22 more files in changeset.
RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

Done.

Done.

Done.

Done.

Isn't fpgaSensorReadings an input?

Isn't fpgaSensorReadings an input?

Restore or remove.

Restore or remove.

DEN-14197: build fixes and warnings.

DEN-14197: Build fixes

DEN-14197: DIAL-212: Created measured RO pump feedback voltage override. Implemented current RO Pump profile variable.

DEN-14197: Fixed warnings regarding gen idle overrides. Fixed compiler issues when merging into develop.

  1. … 1 more file in changeset.
DEN-14197: implemented RO pump profile switching. Implemented Flow to PWM function RO pump with profiles as a parameter. Created a SW fault for PI profiles out of range.

  1. … 4 more files in changeset.
DEN-14197: Initial attempt at PI controller profiles with usage in ro pump

  1. … 2 more files in changeset.
RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

DEN-14175 addressed the code review comments and replaced the V3 enable software configuration flag with the hardware configuration flag from FGPA. Updated the trimmer heater's ramp state to check the use previous duty cycle flag instead of estimating the duty cycle.

  1. … 16 more files in changeset.
This is done to get an average of the fill temperature as well as the last fill temperature prior to tranistioning to Gen Idle. These values are used for the next estimation and are different from ...

This is done to get an average of the fill temperature as well as the last fill temperature prior to tranistioning to Gen Idle. These values are used for the next estimation and are different from the heaters driver.

Done.

Done.