Merge branch 'DEN-14086-alarm-159-dialysate-inlet-pump-failed-flow-vs-motor-speed-check' into develop

DEN-14086: fixed logging issue with LC drift alarm.

Fixed merge conflicts.

  1. … 7 more files in changeset.
DEN-13946 - Correct monitor functions where multiple sensors are "or'd" into a single alarm.

DEN-14086: Increase loadcell drift allowance from +/- 60 to 80 grams - and for heat disinfect, +/- 200 grams.

DEN-14497 updated the drain pump control for the flow and updating chemical disinfect is in progress

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merge branch 'staging' into DEN-14433-sw-s86-mg-publish-fixes

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 84 more files in changeset.
DEN-14101 merged staging

  1. … 4 more files in changeset.
DEN-14101 addressed the code review comments

  1. … 1 more file in changeset.
DEN-14497, DIAL-222 updated the drain pump's control to control the pump to flow in heat disinfect. Added a command to be able to override the heaters duty cycle and reset it. Made the set RO pump to an open loop with a duty cycle a punlic function

  1. … 6 more files in changeset.
Merged DEN-14307

  1. … 6 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 19 more files in changeset.
Merged staging

  1. … 15 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-14307 fixed the concentrate pumps' park command ID and addressed the code review comments. Updated heat disinfect mix drain states with the proper actuators

  1. … 8 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 2 more files in changeset.
DEN-14307: Addressed code review comments.

  1. … 10 more files in changeset.
DEN-14307 updated the concentrate pumps park command

  1. … 1 more file in changeset.
DEN-14307 added a command to be able to start and stop heat disinfect active cool mode. Added a monitor function to check the status of the caps during the heat disinfect active cool mode. Updated heating code to use TD2 temperature sensor to set the primary heater's target for the later DVT devices

  1. … 10 more files in changeset.
DEN-14307: Added support for parking concentrate pumps.

  1. … 12 more files in changeset.
DEN-14307 updated the cleaning modes per the SRS changes

  1. … 7 more files in changeset.
Merge branch 'DEN-14433-sw-s86-mg-publish-fixes' into develop

DEN-14433: DIAL-123: fixed broadcast messages to send if we are >= of their respective intervals instead of >.

Merge branch 'DEN-13050-vpi-does-not-close-after-sample-water-returns-to-flush-idle' into develop

DEN-13757 - Remove unused function monitorLoadCellsWeightOutOfRange/

DEN-13757 - Correction to load cell alarm.

DEN-13757 - All 4 load cells have a single persistent alarm. Change to correspond to how pressure alarms are handled.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 1 more file in changeset.