Fixed merge conflicts.

  1. … 2 more files in changeset.
DEN-9906: reversed prior fix to handling of zero flow from sensor - was right before.

Fixed bugs

  1. … 3 more files in changeset.
Merged DEN-9480 into develop

  1. … 10 more files in changeset.
DEN-9480 updated the RO pump flow monitor

  1. … 1 more file in changeset.
DEN-10412 updated the concentrate pumps to convert the values to negative once the direction of the pumps i negative

  1. … 4 more files in changeset.
DEN-9906: Clear pending pump commands if stop cmd given.

DEN-9906: Don't exit fill on integrated volume per flow. Fix RO flow handling when flow is zero.

  1. … 3 more files in changeset.
DEN-9480, DEN-10419, DEN-10420 addressed the bugs in the mentioned bugs

  1. … 5 more files in changeset.
DEN-9480 work in progress

  1. … 1 more file in changeset.
DEN-9480 Updated the modes for testing

  1. … 5 more files in changeset.
DEN-9906: Fixed bug DEN-10357. Adjusted concentrate pump ramp from 8 mL/min per 1/4 sec to 2 mL/min per 50 ms to smooth out the ramp curve and avoid stalls.

DEN-9906: Fixed min inlet drain pressure for indicating empty reservoir (sign issue).

  1. … 1 more file in changeset.
DEN-9480 work in progress

  1. … 1 more file in changeset.
DEN-9480 removed heaters broadcast function

  1. … 4 more files in changeset.
DEN-9906: Increased load cell drift allowance from one drain tare to the next (DEN-10164). Added check of PRd > 3 PSI before declaring a reservoir empty.

  1. … 1 more file in changeset.
DEN-9480 work in progress, continued adding more control the heaters

  1. … 5 more files in changeset.
DEN-9906: Update drain command message handling.

  1. … 2 more files in changeset.
DEN-9480 merged staging

  1. … 14 more files in changeset.
DEN-9480 worked on the heaters control

  1. … 5 more files in changeset.
DEN-9906: Attempted fix for DEN-9693 and DEN-10140.

DEN-7802: DEN-9693: Reset start heater flag if heater is already on

  1. … 1 more file in changeset.
DEN-9480 worked on developing new heaters control

  1. … 8 more files in changeset.
DEN-7802: Renamed re-circ to generation idle

  1. … 2 more files in changeset.
DEN-7802: Fixed pressure reading

DEN-7802: DEN-9139: Fixed reservoir tare

  1. … 1 more file in changeset.
DEN-7802: Used test support get override value

  1. … 3 more files in changeset.
DEN-7802: Addressed code review comments

  1. … 7 more files in changeset.
DEN-7802: Removed concentrate pump voltage broadcast data

DEN-7802: Removed concentrate pumps voltage monitor and fixed pressure checks

  1. … 2 more files in changeset.