Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

DEN-11114: Restored previous motor controller speed feedback conversion to RPM - it was right before.

Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

This might be reservoir 1 - there is a pre-treatment reservoir mgmt function handling this - check to see which reservoir is active at beginning of prime here.

This might be reservoir 1 - there is a pre-treatment reservoir mgmt function handling this - check to see which reservoir is active at beginning of prime here.

Why reset start time here?

Why reset start time here?

I think this needs to be closed or saline will not be forced across dialyzer into dialysate flow path.

I think this needs to be closed or saline will not be forced across dialyzer into dialysate flow path.

Make it clearer that this is for prime dialyzer state.

Make it clearer that this is for prime dialyzer state.

Dialyzer is spelled with a "z" not "s".

Dialyzer is spelled with a "z" not "s".

I would rename to something like prime dialyzer stop weight.

I would rename to something like prime dialyzer stop weight.

DEN-11114: Fixed conversion issue for pump speed ADC voltage levels.

  1. … 1 more file in changeset.
DEN-11114: Changed syringe ID measurement to median between min and max ID given by manufacturer. Included prime volume in calculation of volume needed to meet needs of treatment.

DEN-11114: Updated syringe inner diameter to improve dispense accuracy. Updated minimum dispense rate to 0.2 mL/hr.

HD-DEN-11098_Implement HD Pre Treatment Mode Update
HD-DEN-11098_Implement HD Pre Treatment Mode Update
DEN-11114: Add 5 sec persistence to blood leak alarm. Make insufficient Heparin volume alarm pre-emptive during seek operation.

Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

DEN-11114: Reset BP rotor count before each treatment starts. Allow BP rotor count override to work even if WORN_CARTRIDGE build flag is enabled.

  1. … 1 more file in changeset.
Disabled watchdog and safety shutdown POST tests for unit 2.

  1. … 4 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 57 more files in changeset.
RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH

RESOLVED in CODE WALKTHROUGH. (On behalf of Behrouz NematiPour who is on vacation)

RESOLVED in CODE WALKTHROUGH. (On behalf of Behrouz NematiPour who is on vacation)

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.