Controllers

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-431 modified the POST and RAM functions

DEN-431 Worked on implemeneting the RAM interface

  1. … 1 more file in changeset.
DEN-431 work in progress, adding the code review comments

  1. … 1 more file in changeset.
Added some more CAN debug code. Minor updates to blood and dialysate pump modules.

  1. … 4 more files in changeset.
DEN-431 worked on the RTC

  1. … 1 more file in changeset.
Added SPI driver for GPIO. Set appropriate motor dir and stop pins for dialysate pump modules. Added calls to init dialysate pump modules. Added exec calls from tasks for dialysate pump modules.

  1. … 8 more files in changeset.
DEN-431 added a test code in taskgeneral to call RTC's functions. Added a check in all the private functions to make sure the tranfer buffer is set correctly prior to RTC operations

  1. … 1 more file in changeset.
Added DialInFlow and DialOutUF modules. Added alarms associated with dialysate pumps.

  1. … 2 more files in changeset.
Updated flow filter in BloodFlow per discussion with Blaine. Added ADC channels for dialysate pumps. Added some debug code for CAN tranmit issue. Added GPIO for dialysate pumps to HALCoGen.

  1. … 18 more files in changeset.
DEN-431 Added #defines to the transfer buffer function

DEN-431 worked on the RAM

DEN-431 Working on the RAM operations

Added RAM and variable transfer buffer functionalities. Added utilities functions to support these features

Added bloodflow overrides for not yet implemented sensors. Condensed published alarms status message.

  1. … 5 more files in changeset.
Code review fix. Adding rounding to BloodFlow module. +review HD-DEN-759-1

  1. … 67 more files in changeset.
Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 82 more files in changeset.
Added place holders for 2 sensors not yet ready for BloodFlow module. Refactored IT for CPLD and SafetyShutdown modules to move from target run to MinGW run tests. Updated UT for SystemComm and SystemCommMessages modules. +review HD-DEN-759-1

  1. … 2 more files in changeset.
DEN-431 updated the epoch function

DEN-431: Added a wrapper to convert time to epoch. Added more states to RTCExec function

DEN-431 Work in progress. Added the functions to convert data to BCD and/to decimal

  1. … 4 more files in changeset.
Added UT for BloodFlow module. Updated other UT. Added IT for AlarmMgmt and BloodFlow modules. Updated other IT. +review HD-DEN-759-1

  1. … 6 more files in changeset.
Started new UT for BloodFlow module. Finished UT for AlarmMgmt module. Fixed issues discovered during UT. +review HD-DEN-759-1

  1. … 5 more files in changeset.
Code review fixes. +review HD-DEN-759-1

Addressed code review feedback. Fixed an intermittent CAN bug. Updated UT for Buttons, CPLD, and Interrupts modules. +review HD-DEN-759-1

  1. … 10 more files in changeset.
Initial commit of the Real Time Clock code

  1. … 10 more files in changeset.
Addressed some code review feedback. Added some checks to BloodFlow monitor function per requirements. +review HD-DEN-759-1

  1. … 3 more files in changeset.
Added UT start for AlarmMgmt module. Finished implementing power off timeout. Added new check-in messages for DG and UI to let HD know it is still communicating. Added delay in bulk of HD powerup until UI starts communicating on CAN to prevent CAN bus error. Added PI control to flow for blood pump. +review HD-DEN-759-1

  1. … 15 more files in changeset.
Added blood pump control per flow. Added timeout to power off request. Added more interrupt handling. Added parity checking for CAN RAM. +review HD-DEN_759-1

  1. … 11 more files in changeset.
Added dialin override support for alarm status publication interval. Added publishing of alarm status every 500ms. Updated UT for SystemComm and SystemCommMessages modules. Started UT for AlarmMgmt module. Addressed code review feedback. +review HD-DEN-759-1

  1. … 8 more files in changeset.
Misc fixes to BloodFlow and AlarmMgmt modules. Scaled BloodFlow analogs. Changed cargo to payload throughout code. Updates to existing UT. +review HD-DEN-759-1

  1. … 15 more files in changeset.