Modes

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-4640: Updates to pump checks. Added messaging/handling of user choosing to go back and try again rather than confirm treatment parameters.

  1. … 4 more files in changeset.
DEN-4640: More fixes for UI integration. Streamlined some build switches.

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 34 more files in changeset.
DEN-5053: Fixed merge conflicts from master. Re-ran local test script.

  1. … 16 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 13 more files in changeset.
DEN-4640: Added saline bolus alarms.

  1. … 4 more files in changeset.
DEN-5053: UT updates.

  1. … 1 more file in changeset.
DEN-4640: Added alarm for weak flow sensor signal strength. Added handling of saline bolus abort from user.

  1. … 3 more files in changeset.
DEN-4640: Saline bolus fixes per lab testing.

DEN-5053: Added build switch to disable alarm for air trap fill timeout.

  1. … 2 more files in changeset.
DEN-5053: More updates to support UI/FW workflow.

  1. … 1 more file in changeset.
DEN-5053: Added build switch for testing where 3-way valves are always open after homing.

  1. … 2 more files in changeset.
DEN-4640: Minor fixes.

  1. … 3 more files in changeset.
DEN-5053: Increased air trap fill volume. Misc adjustments for UI workflow.

  1. … 1 more file in changeset.
DEN-4640: Adjustments for UI workflow.

  1. … 1 more file in changeset.
DEN-4640: Set valve states when starting/resuming dialysis and when pausing treatment.

DEN-4308 addressed the code review comments

DEN-4640: Fixes to treatment parameters response to validation request.

  1. … 3 more files in changeset.
DEN-4308 addressed the code review comments and worked on development testing

  1. … 9 more files in changeset.
DEN-4640: Fix comment.

DEN-4640: Added saline bolus functionality.

  1. … 3 more files in changeset.
DEN-4308 merged master, resolved merge conflicts and continues development testing

  1. … 15 more files in changeset.
DEN-4640: Further developed saline bolus functionality.

  1. … 11 more files in changeset.
DEN-4640: Started saline bolus implementation. Pulled HD valves driver from other feature branch due to valve dependency for the saline bolus feature.

  1. … 8 more files in changeset.
DEN-5053: Added air trap alarms. Added actuator safe state enforcement to fault mode.

  1. … 5 more files in changeset.
DEN-5053: Fixed doxygen function headers for inputs/outputs details section.

  1. … 26 more files in changeset.
DEN-5053: Updated EMC test code to use valve functions. Added Dialin command for resetting f/w processor.

  1. … 6 more files in changeset.
DEN-5053: Addressed code review feedback. Fixes to treatment workflow messaging with UI. Added an alarm lamp sync flag to alarm status message and increased transmission rate from 2 Hz to 4 Hz to allow alarm lamp sync flag to reach UI in timely manner. Added an assertion to give compiler error if new alarm is added to enumeration and not to alarm definition table. Update FPGA UT.

  1. … 14 more files in changeset.
DEN-5053: Additional merge fixes.

  1. … 1 more file in changeset.
DEN-5053: Merged HD valves into this branch due to dependency.

  1. … 15 more files in changeset.