Minor fixes from unit testing. Updates to unit tests.

  1. … 3 more files in changeset.
Updated doxygen comments. Un-macro test functions and override variables in DialOutFlow module.

  1. … 1 more file in changeset.
Updates to time and UF change messaging.

Fixes for UF and treatment time changes. Updated pump factors.

  1. … 6 more files in changeset.
Finished implementation of UF settings change messaging and handling.

  1. … 2 more files in changeset.
Further implementation of UF settings change messaging and handling. Code review fixes.

  1. … 11 more files in changeset.
Changed breadboard build switch to be more biased toward the new HD board. Added UF pause resume functions and message handling. Updated internal ADC voltage and conversion factors for new HD board. Commented out RTC POST until RTC on new HD board is configured.

  1. … 9 more files in changeset.
Added HD specific common header. Streamlined includes for Common.h and HDCommon.h.

  1. … 41 more files in changeset.
Put all debug UART code inside a debug build switch. Misc. other minor changes.

  1. … 17 more files in changeset.
DEN-431 updated the code

Added IT for Dialysis module. Minor updates.

  1. … 3 more files in changeset.
DEN-1778: work in progress.

  1. … 4 more files in changeset.
Initial commit of the branch

  1. … 4 more files in changeset.
CAN Test #1.

  1. … 8 more files in changeset.
Updated off button confirm to cancel off button if off sequence not started. Minor fixes. Started UT module for dialysate outlet pump. Misc. UT updates.

  1. … 7 more files in changeset.
Updated UT for pump modules to include open loop mode.

  1. … 4 more files in changeset.
Updated more doxygen comments.

  1. … 8 more files in changeset.
Tuned UF control. Updated doxygen comments for DialOutFlow and Dialysis modules.

  1. … 5 more files in changeset.
Added dialysis sub-mode. Misc fixes.

  1. … 16 more files in changeset.
Added DPo implementation. Added some messagine for DPo. Added FIRFilters. Updated HALCoGen pinouts.

  1. … 32 more files in changeset.
Added new PresOccl, Dialysis, and TreatmentStop modules. Updated test scripts for system communication modules.

  1. … 13 more files in changeset.
Merged master

  1. … 13 more files in changeset.
Merge branch 'master' into DEN-1312-hd-dialysate-inlet-pump-drive-flow-sensor-control

  1. … 21 more files in changeset.
Removed DialOutFlow module - Leo added to separate branch. Fixed alarm lamp POST.

  1. … 11 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 50 more files in changeset.
Added PIControllers module. Used new PIControllers module in BloodFlow and DialInFlow modules. Moved Watchdog POST to first POST test. Prevent watchdog expired fault during watchdog POST test.

  1. … 5 more files in changeset.
Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 84 more files in changeset.
Addressed code review feedback. Fixed an intermittent CAN bug. Updated UT for Buttons, CPLD, and Interrupts modules. +review HD-DEN-759-1

  1. … 10 more files in changeset.
Initial commit of the Real Time Clock code

  1. … 11 more files in changeset.
Added UT start for AlarmMgmt module. Finished implementing power off timeout. Added new check-in messages for DG and UI to let HD know it is still communicating. Added delay in bulk of HD powerup until UI starts communicating on CAN to prevent CAN bus error. Added PI control to flow for blood pump. +review HD-DEN-759-1

  1. … 14 more files in changeset.