DEN-4641: Added support for Dialin request of calibration data.

  1. … 2 more files in changeset.
DEN-4641: Changed HD pump Dialin set point override commands to simply set commands.

  1. … 6 more files in changeset.
DEN-4641: Calculate HD pump motor speed more frequently. Added support for Dialin command to clear all alarms.

  1. … 9 more files in changeset.
DEN-4640: Addressed code review comments.

  1. … 4 more files in changeset.
DEN-4640: Amended response msg to UF pause/resume request from UI.

  1. … 5 more files in changeset.
DEN-4641: Added pressure alarms. Changed occlusion data type to integer and unit from mmHg to unitless.

  1. … 5 more files in changeset.
DEN-4640: pulled in Dialin command to reset processor from other branch.

  1. … 2 more files in changeset.
DEN-5053: Addressed code review comments.

DEN-4640: Updates to pump checks. Added messaging/handling of user choosing to go back and try again rather than confirm treatment parameters.

  1. … 6 more files in changeset.
DEN-5053: Addressed code review feedback.

DEN-4640: Resolved merge conflicts from DEN-4308 Valves branch.

  1. … 8 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 45 more files in changeset.
DEN-5053: Fixed merge conflicts from master. Re-ran local test script.

  1. … 17 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 15 more files in changeset.
DEN-5053: Fixed merge conflicts w/ valves branch.

  1. … 13 more files in changeset.
DEN-4640: Added handling for HD pump home requests from Dialin.

  1. … 1 more file in changeset.
Added support to broadcast and override flow sensor signal strength.

  1. … 9 more files in changeset.
DEN-4308 addressed the code review comments

  1. … 1 more file in changeset.
DEN-5053: UT updates.

  1. … 1 more file in changeset.
DEN-4640: Fixes to treatment parameters response to validation request.

  1. … 4 more files in changeset.
DEN-4308 addressed the code review comments and worked on development testing

  1. … 9 more files in changeset.
DEN-4640: Added saline bolus functionality.

  1. … 5 more files in changeset.
DEN-4308 merged master, resolved merge conflicts and continues development testing

  1. … 16 more files in changeset.
DEN-4308 addressed code review comments and continued dev testing

  1. … 4 more files in changeset.
DEN-4640: Further developed saline bolus functionality.

  1. … 12 more files in changeset.
DEN-4640: Started saline bolus implementation. Pulled HD valves driver from other feature branch due to valve dependency for the saline bolus feature.

  1. … 9 more files in changeset.
DEN-5053: Fixed doxygen function headers for inputs/outputs details section.

  1. … 36 more files in changeset.
DEN-5053: Updated EMC test code to use valve functions. Added Dialin command for resetting f/w processor.

  1. … 7 more files in changeset.
DEN-4308 Addressed code review comments and continued development testing

  1. … 6 more files in changeset.
DEN-5053: Addressed code review feedback. Fixes to treatment workflow messaging with UI. Added an alarm lamp sync flag to alarm status message and increased transmission rate from 2 Hz to 4 Hz to allow alarm lamp sync flag to reach UI in timely manner. Added an assertion to give compiler error if new alarm is added to enumeration and not to alarm definition table. Update FPGA UT.

  1. … 22 more files in changeset.