Added messaging for blood/dialysate flow rate change and HD to DG dialysate temperature set points.

  1. … 9 more files in changeset.
Perparing for a merge with DEN-1906

  1. … 46 more files in changeset.
Minor fixes from unit testing. Updates to unit tests.

  1. … 3 more files in changeset.
Fixes for UF and treatment time changes. Updated pump factors.

  1. … 9 more files in changeset.
Finished implementation of UF settings change messaging and handling.

  1. … 3 more files in changeset.
Further implementation of UF settings change messaging and handling. Code review fixes.

  1. … 17 more files in changeset.
Changed breadboard build switch to be more biased toward the new HD board. Added UF pause resume functions and message handling. Updated internal ADC voltage and conversion factors for new HD board. Commented out RTC POST until RTC on new HD board is configured.

  1. … 12 more files in changeset.
Added HD specific common header. Streamlined includes for Common.h and HDCommon.h.

  1. … 55 more files in changeset.
Removed CAN ACK build switch.

  1. … 4 more files in changeset.
Put all debug UART code inside a debug build switch. Misc. other minor changes.

  1. … 19 more files in changeset.
Updated power off handling. Added UT for Dialysis module.

  1. … 3 more files in changeset.
CAN Test #1.

  1. … 8 more files in changeset.
Added dialysis sub-mode. Misc fixes.

  1. … 25 more files in changeset.
Added DPo implementation. Added some messagine for DPo. Added FIRFilters. Updated HALCoGen pinouts.

  1. … 38 more files in changeset.
Merged master to branch.

  1. … 8 more files in changeset.
DEN-431 Added the APIs for Dialin

  1. … 3 more files in changeset.
Testing changes as per code review

  1. … 3 more files in changeset.
Minor fixes to CAN ACK.

  1. … 5 more files in changeset.
Added new PresOccl, Dialysis, and TreatmentStop modules. Updated test scripts for system communication modules.

  1. … 16 more files in changeset.
Tuned pump control. Fixed PIController anti-windup. Added some temporary debug code. Added feature to CAN for messages that require an ACK.

  1. … 15 more files in changeset.
Updated code to make it work with dialin

  1. … 3 more files in changeset.
Merge branch 'master' into DEN-1312-hd-dialysate-inlet-pump-drive-flow-sensor-control

  1. … 28 more files in changeset.
Addressed code review comment.

Update CAN interface to test DialOutFlow module

  1. … 8 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 64 more files in changeset.
Added dialin messages for dialysate inlet pump. Fixes to watchdog expired fault. Updates to existing UT.

  1. … 6 more files in changeset.
Updated CAN interrupts config. Added a watchdog expired alarm. Added PWM duty cycle to blood flow broadcast.

  1. … 18 more files in changeset.
Updated flow filter in BloodFlow per discussion with Blaine. Added ADC channels for dialysate pumps. Added some debug code for CAN tranmit issue. Added GPIO for dialysate pumps to HALCoGen.

  1. … 19 more files in changeset.
Added bloodflow overrides for not yet implemented sensors. Condensed published alarms status message.

  1. … 6 more files in changeset.
Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 84 more files in changeset.