HDCommon.h

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-11098 Resolved merge conflicts

  1. … 5 more files in changeset.
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

DEN-11098 Removed code related to run blood circuit again because it no longer needed

  1. … 1 more file in changeset.
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 112 more files in changeset.
DEN-11098 Incorporated peer review comments

  1. … 1 more file in changeset.
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

DEN-11098 Added compiler switch RUN_BLOOD_CIRCUIT_PRIME_AGAIN

  1. … 1 more file in changeset.
DEN-11089 Correction - dialyzer dialysate bypass priming path uses R1 instead of R2 and dialyzer dialysate priming path uses R2 instead of R1

  1. … 1 more file in changeset.
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 71 more files in changeset.
DEN-9906: Fixed merge conflicts from staging.

  1. … 61 more files in changeset.
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 11 more files in changeset.
DEN-9906: Removed obsolete build switch for old FMD sensor.

DEN-9906: Added build switch for disabling UI comm timeout alarm.

  1. … 1 more file in changeset.
DEN-9906: Added build switch to estimate PBA instead of reading PBA.

  1. … 1 more file in changeset.
DEN-9906: Fix filtering for FMD from DG.

  1. … 3 more files in changeset.
DEN-9906: Restored deleted flow vs. speed checks for BP and DPi pumps. Fixed units for new dialysate flow sensor.

  1. … 2 more files in changeset.
DEN-9906: Added overrides for blood pump rotor count and arterial pressure offset. Removed unused handling of DG data and related functions/variables. Fixed DEN-10973.

  1. … 11 more files in changeset.
DEN-9906: Addressed code review comments.

  1. … 5 more files in changeset.
DEN-10153: Treatment log's prescribed ultrafiltration volume and rate

- band-aid the staging branch to be able to build

- updated the volume treatmentLogData struct to provide original ultrafiltration volume(L) and rate(mL/min), to includ in the treatment log response in the post-treatment mode.

- updated the originTreatmentParams to store original ultrafiltration volume(L) and rate(mL/min) (set by user during the pre-treatment mode), to query later for the treatment log.

- stored the original ultrafiltration volume if the user set volume is accepted in the pre-treatment mode.

- modified the sendTreatmentLogData function to use the correct type of accepted value from F32 to Bool (although both are the same updated to be consistent.)

  1. … 7 more files in changeset.
DEN-9906: Added build switch for use with used/worn cartridge.

  1. … 3 more files in changeset.
DEN-9906: Updated blood flow estimation per FPrin model.

  1. … 3 more files in changeset.
DEN-10158 addressed the HD valves by holding the next command

  1. … 7 more files in changeset.
DEN-9906: Addressed bug DEN-9692 re: inline pressure range checks not clearing properly.

  1. … 1 more file in changeset.
Run DPi open loop too for clearance testing.

  1. … 2 more files in changeset.
No inline pressure checks if disabled by build flag. If build flag says no prime, fill reservoirs all the way.

  1. … 2 more files in changeset.
DEN-9906: Added build switches to use FMB/FMD or their replacements.

  1. … 7 more files in changeset.