Matched DG arrangement and fix for CAN Tx. Added inlet conductivity alarm ID.

  1. … 5 more files in changeset.
Handle CAN and UART error/warning notifications. Differentiated HD from DG s/w fault. Updated some older module/function headers to latest format.

  1. … 24 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 70 more files in changeset.
UT updates. Added UT for DGInterface. Misc fixes per UT.

  1. … 5 more files in changeset.
Added misc test/debug build flags. Added persistence to CAN buffer overflow faults so that we can try to recover from one-off spurts when a node is coming online.

  1. … 10 more files in changeset.
Fixed UF change verification logic. Fixed doxygen comments.

  1. … 3 more files in changeset.
Made reservoir target volumes public. Set all UF volumes to F32 type for consistency.

  1. … 5 more files in changeset.
Addressed code review feedback. Fixed treatment time minimum range to UI message.

  1. … 1 more file in changeset.
Fixed message payload sizing issue on UF option confirmation message handling.

  1. … 2 more files in changeset.
Changed max dialysate volume from 180 to 150 L. Split UF change response messages into 2 separate messages to prevent UI confusion.

  1. … 2 more files in changeset.
Added safety shutdown override command support. Zero treatment duration param in response to UF adjustment message if time adjustment should be disabled.

  1. … 7 more files in changeset.
Moved modes and sub-modes enums to common header. Added sub-mode to HD op mode broadcast. Added current UF rate to UF rate change response to UI.

  1. … 29 more files in changeset.
Misc UF fixes. Changed CAN from FIQ to IRQ to see if helps with intermittent lockup.

  1. … 10 more files in changeset.
Implemented some test code of UF demo support in Standby mode. Started a state machine for treatment mode reservoir management.

  1. … 4 more files in changeset.
Added minimum 1 hr treatment to settings adjustment range checks. Changed blood/dialysate inlet pump flow rate filter approach. Changed blood/dialysate inlet pump control interval to 10 sec.

  1. … 2 more files in changeset.
UT/IT updates.

  1. … 3 more files in changeset.
Fixes for eval board build for Behrouz.

  1. … 10 more files in changeset.
Updates to UT/IT. Minor code fixes per UT/IT.

  1. … 4 more files in changeset.
Code review fixes. Moved task interrupts to notifications.

  1. … 6 more files in changeset.
Added treatment settings range update message. Addressed code review feedback.

  1. … 5 more files in changeset.
Fixes per unit testing. Added UT/IT for NVDataMgmt module. Added UT for ModeTreatment module. Updated other unit tests.

  1. … 4 more files in changeset.
Minor messaging updates.

  1. … 5 more files in changeset.
Updated UF and Treatment time changes during treatment.

  1. … 2 more files in changeset.
Added messaging for blood/dialysate flow rate change and HD to DG dialysate temperature set points.

  1. … 9 more files in changeset.
Perparing for a merge with DEN-1906

  1. … 46 more files in changeset.
Minor fixes from unit testing. Updates to unit tests.

  1. … 3 more files in changeset.
Updated doxygen comments. Un-macro test functions and override variables in DialOutFlow module.

  1. … 4 more files in changeset.
Updates to time and UF change messaging.

  1. … 2 more files in changeset.
Fixes for UF and treatment time changes. Updated pump factors.

  1. … 9 more files in changeset.
Finished implementation of UF settings change messaging and handling.

  1. … 3 more files in changeset.