DEN-9639: Code Review 0

- Addressed code reviews

- Reoved LOG_DEBUG_UI since the DEBUG log is all about UI and adding a UI to it was useless.

- Removed the time stamp from the POST start/stop log since the log itself has timestamp.

- Added more documentation to the ApplicationPOST class.

- Renamed the FileSystem to ShaSum check in the ApplicationPOST.

- Updated the WiFi POST check funciton.

- Updated the initial Screen to pause the animation when the UI navigates out of that screen when we are in test (usual case should not happen since we fail or pass the POST and either stops the animation.)

- Updated the AlarmMapping to reflect the FILESYSTEM error change to SHASUM error.

  1. … 19 more files in changeset.
Updated Alarm Mappings

  1. … 1 more file in changeset.
DEN-9655: Implementation - Settings [MVC]

DEN-9657: Implementation - Event Driven Reading

DEN-9658: Implementation - Treatment Log

  1. … 18 more files in changeset.
[ DEN-9653 , DEN9655 ] : Implementation - Settings [ Screen , MVC ]

  1. … 17 more files in changeset.
DEN-9707: BP/HR empty measurement display does not match PRS

- alarm mapping update.

- post code review applied here.

  1. … 4 more files in changeset.
Bamboo Commit: Updated MAlarmMapping.cpp

DEN-9614: Meetings & Support - General Support

- Trying to have a first run after a while on the unit tests.

  1. … 2 more files in changeset.
Bamboo Commit: Updated MAlarmMapping.cpp

DEN-9649: Implementation - Yocto configuration

- Addressed some frequent code review comments

- Fixed the UI POST AlarmTriggered message

- Added the deleteLater for the QQuickViewer pointer _viewer.

  1. … 114 more files in changeset.
Bamboo Commit: Updated MAlarmMapping.cpp

DEN-9416: Implementations

- Added a newly added parameter of the BloodPrime (Safety Vol).

- UI POST is done.

- Out of 10 tests

1 - CANBus

2 - Touch Screen

3 - SD-Card

4 - RTC

tests are done.

- The

5 - File System integrity

will be done as part of CyberSecurity.

- The

6 - Bluetooth

will be added when the feature itself added to the application.

- The

7 - WiFi

is in progress and having issue correctly detect it.

- Some tests are listed to be added later in case required, like

8 - Display

9 - Ethernet

10- Sound

test couldn't find a way to test it yet.

- On each unsuccessful test an alarm will be triggered.

- UI alarms are in range of [250 - 259]

  1. … 18 more files in changeset.
DEN-9416: Implementation

- Implementing the foundation of Application POST

- Added ID_AlarmTriggered message on post error.

- Added AdjustUIPostFinalResultRequestData in correct place.

- Created the treading structure for the post to start.

  1. … 13 more files in changeset.
Bamboo Commit: Updated MAlarmMapping.cpp

DEN-9299: Meetings & Support - General Support

- Sending the "ui version req" and the "ui post final" was even before the check in since the initial screen became the landing screen.

- those two has been moved to the actual state change to wait for the HD to change the state to init then send those messages.

  1. … 5 more files in changeset.
Bamboo Commit: Updated MAlarmMapping.cpp

Bamboo Commit: Updated MAlarmMapping.cpp

Bamboo Commit: Updated MAlarmMapping.cpp

DEN-9299: Implement a function to log unhandled messages like the other ones but at least the definition in a list hardcoded in the code.

- It has been requested by V&V team to add unhandled messages to the log to be able to query them.

  1. … 6 more files in changeset.
Alarm mapping update.

DEN-9142: Meetings & Support - General Support

- Added Dialin channels as "Debug" channels in the UI Log for V&V canbus testing (All were Unexpected before.)

- Added label for the Diagnostics screen

- The SD-CArd Indicator's mouse area made bigger to easier double touch it.

  1. … 9 more files in changeset.
DEN-9142: Meetings & Support - General Support

- Updating the blood/dialysate flow ranges/resolution.

- Updated the Serial messages length from 10 to 15 bytes.

- Having some work done testing the plotting component.

  1. … 7 more files in changeset.
DEN-8705: Pre-Treatment Setup Screen

- Usability tests feedback modifications

- A/V Pressure Limits ranges update regarding PRS changes.

  1. … 11 more files in changeset.
DEN-8937: Meetings & Support - General Support

- Updated the main Treatment Log message parameters.

  1. … 15 more files in changeset.
DEN-DEN-8937: Meetings & Support - General Support

- Modified the DG disinfect states message to use the new FW enum instead of the temporary UI one.

  1. … 8 more files in changeset.
Update Alarm Mapping

- Also reverted back the timeout interval to 1 min.

  1. … 1 more file in changeset.
DEN-8693: Meetings & Support - General Support

- Updated the Alarm Mapping to add Alarm index on each line as comment.

- Added Flush States

- Fixed message 0x7700 length error.

  1. … 8 more files in changeset.
Update Alarm Mapping

  1. … 1 more file in changeset.
DEN-8693: Support for the disinfect

- Adding support for reading the brightness value from the Linux file system instead of having another file just to keep the same value.

- Fixed a bug in the Active Alarm List request.

- Adding the functionality of the Alarm Volume.

- Modified the Disinfection screens[Heat/chem] check marks with the new bundled states provided by FW for UI and the flush states are yet to come.

- Adjusted the Active Alarm List screen a little to be able to show all the current Alarm messages without cropping.

  1. … 26 more files in changeset.
DEN-8523: Bluetooth cuff

- Although there is not specific Bluetooth setting appear here but the entire idea here is to prepare the application to have a better platform for device handling like Bluetooth and the other ones.

  1. … 21 more files in changeset.
Update Alarm Mapping

  1. … 1 more file in changeset.