LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation

- Adjust TD and DD descriptions to match fn implementation

- Add MSG ID to all TD and DD implemented messages

  1. … 1 more file in changeset.
LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation

- Add Air bubbles and Air Pump message

LDT-566: fixes to unit testing and msg id naming

  1. … 6 more files in changeset.
LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

Change Treatment Set point Data in UI/td_messaging to match dialin enum

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Fix common .py pressure ranges format

- Adjust TD messaging doxygen comments and correct payload for ejector, switches, and battery to unsigned int

  1. … 1 more file in changeset.
LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

removing TD bubbles and air pump for future implementation

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Adjust pressure limits in common.py

- Adjust GenDialysate payload naming

- Change TD blood pump to blood flow

  1. … 2 more files in changeset.
LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Add TX State message

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Adjust DD/TD Payload naming to have FW valve naming scheme

  1. … 1 more file in changeset.
LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Add enum for TX set point data

- fix payload issues with DD conductivity and Gen dialysate

- fix payload issues with TD messaging

  1. … 3 more files in changeset.
LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Add Main treatment TD messages: Pressure and occlusion, saline, set point data, treatment time, and UF

- Add Main treatment DD messages: Conductivity, Generate dialysate

  1. … 1 more file in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into staging

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Added a comment to trigger the not detected changes in the merge.

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Add DD messgaing for versions and serial number

- add Missing MSG ID enums

- address CR comments in TD messaging

  1. … 2 more files in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Add dialin enums to all hardcoded message IDs

- Fix td_serial name

- remove all hardcoded parameters

  1. … 1 more file in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Make adjustments for TD blood pump message and payload conversion

LDT-458 Treatment Parameters (Create Rx) - SW - 08: DEV - Dialin Implementation

- the alarm system is incomplete.

  1. … 1 more file in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Adjust ejector message to match leahi MSG list updates

- Adjust switches message to match leahi MSG list updates

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Adjust td version and serial message

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implement

- Add TD valve messaging to ui messaging

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Added all messaging needed for diagnostics except TD versions

Base TD messaging for diagnostics screen

Base TD messaging for diagnostics screen

LDT-242 Main Treatment Screen - SW - Simulator Cleanup - 05: DEV - Feature Implementation

- Fixed the issues caused SWVV main test to fail.

  1. … 7 more files in changeset.
LDT-242 Main Treatment Screen - SW - Simulator Cleanup - 05: DEV - Feature Implementation

- Refactored HD to TD and simplified the function names that going to use the format later as well.

LDT-242 Main Treatment Screen - SW - Simulator Cleanup - 05: DEV - Feature Implementation

- Renamed the td_messaging.py to lowercase to match the rest of the modules.

  1. … 1 more file in changeset.