LDT-934: Main Treatment Screen - SW - Diagnostics Screen-FP - 08: DEV - Dialin Implementation

- Add The following FP message implementation

Versions

Pressure

Flow

Conductivity

Temperature

Valves

ROPump

BoostPump

Level

    • -0
    • +356
    ./fp_messaging.py
Merge branch 'feature/LDT-907-Main-Treatment-Screen-SW-Diagnostics-Screen-DD-2' into staging

  1. … 1 more file in changeset.
LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation - Implement DD Valves Message

LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation

- Adjust TD and DD descriptions to match fn implementation

- Add MSG ID to all TD and DD implemented messages

LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation

- Add Air bubbles and Air Pump message

LDT-915: Main Treatment Screen - SW - Diagnostics Screen-DD - 08: DEV - Dialin Implementation

- Add Blood leak message as 0x60

- Add The following DD messages: levels, pressure, temperature, heaters, concentrate pumps, dialysate pumps, blood leak

  1. … 1 more file in changeset.
LDT-566: fixes to unit testing and msg id naming

  1. … 5 more files in changeset.
LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

Change Treatment Set point Data in UI/td_messaging to match dialin enum

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Fix common .py pressure ranges format

- Adjust TD messaging doxygen comments and correct payload for ejector, switches, and battery to unsigned int

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

removing TD bubbles and air pump for future implementation

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Adjust pressure limits in common.py

- Adjust GenDialysate payload naming

- Change TD blood pump to blood flow

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Add TX State message

LDT-630: Main Treatment Screen - SW - Messaging Broadcast - 08: DEV - Dialin Implementation

- Adjust DD/TD Payload naming to have FW valve naming scheme

LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Add enum for TX set point data

- fix payload issues with DD conductivity and Gen dialysate

- fix payload issues with TD messaging

  1. … 1 more file in changeset.
LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Add Main treatment TD messages: Pressure and occlusion, saline, set point data, treatment time, and UF

- Add Main treatment DD messages: Conductivity, Generate dialysate

LDT-718: General Alarm Requirements - SW - 05: DEV - Feature Implementation

Addressing code review comment(s):

- http://devapps.diality.us:8060/cru/LEAHI-APPLICATION-LDT-713-1#CFR-67867

LDT-718: General Alarm Requirements - SW - 05: DEV - Feature Implementation

- Added and updated the alarm messages for the Leahi.

Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into staging

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Added a comment to trigger the not detected changes in the merge.

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Add DD messgaing for versions and serial number

- add Missing MSG ID enums

- address CR comments in TD messaging

  1. … 1 more file in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Add dialin enums to all hardcoded message IDs

- Fix td_serial name

- remove all hardcoded parameters

  1. … 1 more file in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Make adjustments for TD blood pump message and payload conversion

LDT-458 Treatment Parameters (Create Rx) - SW - 08: DEV - Dialin Implementation

- the alarm system is incomplete.

    • -0
    • +97
    ./td_messaging_alarms.py
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Adjust ejector message to match leahi MSG list updates

- Adjust switches message to match leahi MSG list updates

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Adjust td version and serial message

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implement

- Add TD valve messaging to ui messaging

Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Added all messaging needed for diagnostics except TD versions

Base TD messaging for diagnostics screen

Base TD messaging for diagnostics screen

LDT-242 Main Treatment Screen - SW - Simulator Cleanup - 05: DEV - Feature Implementation

- Fixed the issues caused SWVV main test to fail.

  1. … 7 more files in changeset.