This is a list of all comments for DG-DEN-15660-1. Review Summary: No summary ---------------------------------------- File: firmware/App/Controllers/TemperatureSensors.c Revision Comment by Sean Nash on 10 July 2023, 17:20 https://devapps.diality.us/cru/DG-DEN-15660-1#c18030 Don't like "timeout" in this constant. It's not really a timeout. It's a sample time (or collection time if you prefer). Change TIMEOUT to TIME. Reply by Dara Navaei on 12 July 2023, 08:51 > Done Reply by Sean Nash on 12 July 2023, 10:49 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 10 July 2023, 17:22 https://devapps.diality.us/cru/DG-DEN-15660-1#c18031 Swap first and TRo positions in enum. TRo should be first, then we add a first to mark it as first. Reply by Dara Navaei on 12 July 2023, 08:49 > Done Reply by Sean Nash on 12 July 2023, 10:50 > TRo needs comment for doxygen. Reply by Sean Nash on 12 July 2023, 15:44 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 10 July 2023, 17:34 https://devapps.diality.us/cru/DG-DEN-15660-1#c18032 Do we still want un-averaged TDi and TRo in this broadcast? Is anybody using them? If not, why not replace the old temps with the new averages? Reply by Dara Navaei on 12 July 2023, 08:46 > The un-averaged TDi and TRo are used for dialysate > temperature checking and trimmer heater control I think we > should keep them to be able to have a full picture if needed > unless the CAN bus is really flooded. Reply by Sean Nash on 12 July 2023, 10:53 > RESOLVED in CODE WALKTHROUGH. ---------------------------------------- File: firmware/App/Modes/ModeChemicalDisinfect.c Revision Comment by Sean Nash on 10 July 2023, 17:37 https://devapps.diality.us/cru/DG-DEN-15660-1#c18033 Is this really a timeout? Or is it a minimum duration? Reply by Dara Navaei on 12 July 2023, 08:44 > This is a time and not timeout. Reply by Sean Nash on 12 July 2023, 10:51 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 10 July 2023, 17:37 https://devapps.diality.us/cru/DG-DEN-15660-1#c18034 Replace "TIMEOUT" with "TIME" Reply by Dara Navaei on 12 July 2023, 08:42 > Done Reply by Sean Nash on 12 July 2023, 10:51 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 10 July 2023, 17:56 https://devapps.diality.us/cru/DG-DEN-15660-1#c18035 Can we move these declarations up to top of scope? Reply by Dara Navaei on 12 July 2023, 08:41 > Done Reply by Sean Nash on 12 July 2023, 10:52 > RESOLVED in CODE WALKTHROUGH. Revision Comment by wbracken on 26 June 2023, 14:03 https://devapps.diality.us/cru/DG-DEN-15660-1#c17999 Add nelsonSupport, stateTrialCounter to header. Reply by Dara Navaei on 12 July 2023, 09:58 > Nelson is not part of the commercial code. Reply by wbracken on 12 July 2023, 13:26 > RESOLVED IN CODE WALKTHROUGH Revision Comment by wbracken on 26 June 2023, 14:04 https://devapps.diality.us/cru/DG-DEN-15660-1#c18000 Add stateTrialCounter Reply by Dara Navaei on 12 July 2023, 09:57 > Done Reply by wbracken on 12 July 2023, 13:27 > RESOLVED IN CODE WALKTHROUGH Revision Comment by wbracken on 26 June 2023, 14:06 https://devapps.diality.us/cru/DG-DEN-15660-1#c18001 Update header: rsrvr2Status, isRsrveLeadking, chemDisinfectReservoirTime, isChemDisinfectTempAboveTarget, ischemDisinfectWarmupTargetReached (should be isChemDisinfectWarmupTargetReached). Reply by Dara Navaei on 12 July 2023, 09:08 > Done Reply by wbracken on 12 July 2023, 13:32 > RESOLVED IN CODE WALKTHROUGH Revision Comment by wbracken on 26 June 2023, 14:09 https://devapps.diality.us/cru/DG-DEN-15660-1#c18002 Update header. Reply by Dara Navaei on 12 July 2023, 09:06 > Done Reply by wbracken on 12 July 2023, 13:27 > RESOLVED IN CODE WALKTHROUGH Revision Comment by wbracken on 26 June 2023, 14:10 https://devapps.diality.us/cru/DG-DEN-15660-1#c18003 Add nelsonSupport Reply by Dara Navaei on 12 July 2023, 08:52 > Nelson support is only in debug mode. Reply by wbracken on 12 July 2023, 13:28 > RESOLVED IN CODE WALKTHROUGH ---------------------------------------- File: firmware/App/Modes/ModeFill.c Revision Comment by Sean Nash on 11 July 2023, 09:05 https://devapps.diality.us/cru/DG-DEN-15660-1#c18036 This looks strange. If we have a empty bottle alarm, shouldn't we just not start a fill in the first place? With this approach, you're just stuck in fill start state until user clears the alarm. Reply by Sean Nash on 12 July 2023, 10:53 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 11 July 2023, 09:08 https://devapps.diality.us/cru/DG-DEN-15660-1#c18037 What about acid? Reply by Dara Navaei on 12 July 2023, 08:39 > Done Reply by Sean Nash on 12 July 2023, 10:48 > RESOLVED in CODE WALKTHROUGH. ---------------------------------------- File: firmware/App/Modes/ModeGenIdle.c Revision Comment by wbracken on 11 July 2023, 17:30 https://devapps.diality.us/cru/DG-DEN-15660-1#c18042 handleEmptyBottleFlag is only an input Reply by Dara Navaei on 12 July 2023, 08:39 > Done Reply by wbracken on 12 July 2023, 13:30 > RESOLVED IN CODE WALKTHROUGH --- ID: DG-DEN-15660-1 https://devapps.diality.us/cru/DG-DEN-15660-1 Title: DG-DEN-15660_Test Configuration Treatment Recovery Statement of Objectives: State: Closed Summary: Author: Dara Navaei Moderator: Dara Navaei Reviewers: (5 active, 1 completed*) Sean Nash (*) Michael Garthwaite wbracken Darren Cox jtaylor Steve Jarpe