This is a list of all comments for DIALIN-DEN-3504-1. Review Summary: No summary ---------------------------------------- File: dialin/common/msg_defs.py Revision Comment by plucia on 02 November 2020, 11:21 https://devapps.diality.us/cru/DIALIN-DEN-3504-1#c5862 These two have the same ID Reply by qnguyen on 02 November 2020, 13:44 > This is a part of DEN-4640. It has been fixed in the latest > develop branch. > MSG_ID_UI_ALARM_ACKNOWLEDGE has been removed and replaced > with MSG_ID_UI_ALARM_USER_ACKNOWLEDGE. Reply by plucia on 09 November 2020, 10:03 > RESOLVED ---------------------------------------- File: dialin/dg/concentrate_pumps.py Revision Comment by plucia on 18 November 2020, 17:53 https://devapps.diality.us/cru/DIALIN-DEN-3504-1#c6259 Use the Dialin enum here to avoid duplicating has_value Reply by qnguyen on 18 November 2020, 21:52 > Done. Reply by plucia on 19 November 2020, 10:14 > RESOLVED ---------------------------------------- File: dialin/dg/dialysate_generator.py Revision Comment by Sean Nash on 09 November 2020, 10:14 https://devapps.diality.us/cru/DIALIN-DEN-3504-1#c5936 I'm not convinced we can change modes via Dialin command. For one thing, many mode transitions are illegal and will cause a system fault. But even if mode change is legal, changing via external command bypasses internal state machine constraints and workflow leaving you in a new mode without proper context. Reply by qnguyen on 09 November 2020, 11:54 > Removed. Reply by plucia on 10 November 2020, 13:38 > Sean isn't this part of the request in DIAL-2 - Set Operation > Modes? Maybe we should discuss Reply by Sean Nash on 16 November 2020, 08:27 > Yes, it is, but with none of my concerns dealt with. It > will not be this simple. Reply by Sean Nash on 20 November 2020, 09:50 > RESOLVED. ---------------------------------------- File: dialin/dg/alarms.py Revision Comment by pmontazemi on 04 November 2020, 08:43 https://devapps.diality.us/cru/DIALIN-DEN-3504-1#c5905 Why removed? Reply by qnguyen on 04 November 2020, 11:50 > The alarm ids can be obtained directly from AlarmList class > in dialin/common/alarms_defs.py. Reply by pmontazemi on 10 November 2020, 18:37 > RESOLVED. --- ID: DIALIN-DEN-3504-1 https://devapps.diality.us/cru/DIALIN-DEN-3504-1 Title: DIALIN-DEN-3504_DG Dialysate Composition (1 of 2) Statement of Objectives: State: Closed Summary: Author: qnguyen Reviewers: (0 active, 3 completed*) Sean Nash (*) plucia (*) pmontazemi (*)