This is a list of all comments for HD-DEN-15330-1. Review Summary: No summary ---------------------------------------- File: firmware/App/Modes/TreatmentStop.c Revision Comment by Sean Nash on 15 June 2023, 10:09 https://devapps.diality.us/cru/HD-DEN-15330-1#c17913 Don't need this include. Reply by Michael Garthwaite on 15 June 2023, 10:17 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 16:28 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 14 June 2023, 17:10 https://devapps.diality.us/cru/HD-DEN-15330-1#c17898 If you search for where execReservoirs() is called, you will see that it's already called by ModeTreatment.c right before this function is called. Reply by Michael Garthwaite on 15 June 2023, 09:45 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 10:10 > RESOLVED in CODE WALKTHROUGH. ---------------------------------------- File: firmware/App/Services/Reservoirs.c Revision Comment by Sean Nash on 14 June 2023, 17:13 https://devapps.diality.us/cru/HD-DEN-15330-1#c17899 Add space between if and (. Reply by Michael Garthwaite on 15 June 2023, 09:44 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 10:13 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 14 June 2023, 17:14 https://devapps.diality.us/cru/HD-DEN-15330-1#c17900 Why is this a separate condition when it's doing the exact same thing as above? Reply by Michael Garthwaite on 15 June 2023, 09:46 > With this being a WIP im unsure at the moment if both > conditions need to do the same thing. Reply by Sean Nash on 15 June 2023, 10:11 > Looks like they do need to do the same thing. We should > combine with condition above. Reply by Michael Garthwaite on 15 June 2023, 17:13 > Combined. Thanks! Reply by Sean Nash on 16 June 2023, 11:05 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Dara Navaei on 14 June 2023, 18:23 https://devapps.diality.us/cru/HD-DEN-15330-1#c17904 Please remove the extra blank line. Reply by Michael Garthwaite on 15 June 2023, 09:44 > Fixed. Thanks! Reply by Dara Navaei on 16 June 2023, 10:35 > RESOLVED in CODE WLAKTHROUGH Revision Comment by Sean Nash on 15 June 2023, 10:16 https://devapps.diality.us/cru/HD-DEN-15330-1#c17919 Align the TRUEs. Reply by Michael Garthwaite on 15 June 2023, 10:19 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 16:28 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 14 June 2023, 17:15 https://devapps.diality.us/cru/HD-DEN-15330-1#c17901 I think we should be checking alarm condition instead of alarm active. Temperature may have come back into range (condition cleared) but user hasn't resumed to clear alarm (maybe stepped away for a minute). Reply by Michael Garthwaite on 15 June 2023, 09:45 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 10:14 > RESOLVED in CODE WALKTHROUGH. Revision Comment by Sean Nash on 14 June 2023, 17:16 https://devapps.diality.us/cru/HD-DEN-15330-1#c17902 Add blank line after function scope. Reply by Michael Garthwaite on 15 June 2023, 09:45 > Fixed. Thanks! Reply by Sean Nash on 15 June 2023, 10:12 > RESOLVED in CODE WALKTHROUGH. --- ID: HD-DEN-15330-1 https://devapps.diality.us/cru/HD-DEN-15330-1 Title: HD-DEN-15330_Dialysate Temp Alarm Recovery Takes A Long Time NO Reservoir Switching Statement of Objectives: State: Closed Summary: Author: Michael Garthwaite Moderator: Michael Garthwaite Reviewers: (4 active, 2 completed*) Sean Nash (*) wbracken (*) Dara Navaei Darren Cox jtaylor Steve Jarpe