This is a list of all comments for LEAHI-DIALIN-LDT-2662-1. Review Summary: No summary ---------------------------------------- File: leahi_dialin/ui/fp_messaging.py Revision Comment by Sean Nash on 20 October 2025, 16:04 https://devapps.diality.us/cru/LEAHI-DIALIN-LDT-2662-1#c24737 Should M12 come after M4? Reply by jpaguio on 20 October 2025, 17:02 > done - reordered list to match current FP implementation Revision Comment by Sean Nash on 20 October 2025, 16:06 https://devapps.diality.us/cru/LEAHI-DIALIN-LDT-2662-1#c24738 Fix spacing, align "<<". Should all of the M valves come first? I didn't see an M7 valve in other contexts. Is M7 obsolete? Reply by jpaguio on 20 October 2025, 17:02 > done - reordered list to match current FP implementation --- ID: LEAHI-DIALIN-LDT-2662-1 https://devapps.diality.us/cru/LEAHI-DIALIN-LDT-2662-1 Title: LEAHI-DIALIN-LDT-2662_Beta 1.0 FW Integration Part 2 - DD Implementation Statement of Objectives: State: Closed Summary: Author: Dara Navaei Moderator: Dara Navaei Reviewers: (2 active, 5 completed*) Sean Nash (*) Vinayakam Mani (*) Michael Garthwaite (*) Raghu Kallala (*) Behrouz NematiPour (*) Nicholas Ramirez Stephen Quong