Index: AlarmMapping.csv =================================================================== diff -u -r6c6f1f5d466badd9b4fd67be7c907234c342b2a2 -r9891a1deb940324058d295bcd3ff5e55c47701c2 --- AlarmMapping.csv (.../AlarmMapping.csv) (revision 6c6f1f5d466badd9b4fd67be7c907234c342b2a2) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision 9891a1deb940324058d295bcd3ff5e55c47701c2) @@ -45,7 +45,7 @@ 44,"HD UI communication timeout." 45,"HD too many bad communications CRC." 46,"HD didn't get ACK on message to UI that required acknowledgment." - 47,"Available for use." + 47,"DG maximum RO Pump PWM exceeded." 48,"HD ultrafiltration volume accuracy error during treatment." 49,"HD FPGA communication down for too long." 50,"DG FPGA not accepting commanded valve states." @@ -61,7 +61,7 @@ 60,"HD valve not functional." 61,"HD valve current out of range." 62,"HD valve position out of target." - 63,"HD blood leak FPGA fault." + 63,"HD syringe pump prime timeout." 64,"DG barometric pressure sensor out of range." 65,"HD DG requests DG command with invalid parameter fault." 66,"HD blood leak sensor set point set failure." @@ -90,15 +90,15 @@ 89,"DG outlet UV reactor on with no flow." 90,"DG load cells A1/B1 FPGA fault." 91,"HD No dialysate flow data receive in the last 3 seconds." - 92,"Available for use." + 92,"DG temperature sensors invalid calibration record." 93,"DG outlet primary conductivity out of range." 94,"DG pressure out of range." 95,"DG watchdog expired." 96,"DG inlet water temperature in high range." 97,"DG fill conductivity out of range." 98,"HD battery communication fault." 99,"HD syringe pump stall alarm." - 100,"Available for use." + 100,"DG conductivity sensors invalid temperature compensation calibration record." 101,"UI POST HD communication failure." 102,"DG heat disinfect temperature gradient out of range." 103,"HD invalid calibration CRC." @@ -127,7 +127,7 @@ 126,"HD blood leak detected alarm." 127,"HD venous pressure too low during treatment." 128,"HD venous air bubble detected alarm." - 129,"Available for use." + 129,"HD blood leak recovering please wait." 130,"HD venous pressure too high during treatment." 131,"HD arterial pressure too low during treatment." 132,"HD arterial pressure too high during treatment." @@ -201,7 +201,7 @@ 200,"DG thermistors/sensors temperature out of range." 201,"HD pre-treatment mode wet self-test lc vs FMD failure." 202,"HD pre-treatment mode dry pressure normal self-test failure." - 203,"Available for use." + 203,"DG fill conductivities acid/bicarb invalid calibration record." 204,"DG RO rejection ratio out of range." 205,"DG conductivity sensor fault." 206,"DG dialysate fill runs out of time." @@ -235,7 +235,7 @@ 234,"DG inlet water pressure in high range." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." 236,"HD needs new cartridge to be installed." - 237,"Available for useALARM_ID_AVAILABLE_13." + 237,"Available for use." 238,"HD no cartridge loaded or installed improperly alarm." 239,"HD fail to remove cartridge alarm." 240,"DG bicarb conductivity out of range during bicarb pump check alarm." @@ -256,7 +256,7 @@ 255,"HD and UI software builds are not compatible." 256,"HD processor is in Disinfect Chemical Flush mode." 257,"Alarm ID available for use." - 258,"Alarm Id available." + 258,"HD UI POST OS version compatibility failure." 259,"HD temperatures out of range." 260,"HD UI POST Application Integrity (Sha256Sum) failure." 261,"HD UI POST CANBus failure." @@ -272,7 +272,7 @@ 271,"DG POST Safety Shutdown failure." 272,"HD Fan RPM out of range." 273,"Available for use." - 274,"Available for use." + 274,"DG inactive reservoir weight out of range." 275,"HD arterial pressure sensor is reading out of range." 276,"HD venous pressure sensor is reading out of range." 277,"HD BP occlusion sensor is reading out of range." @@ -304,7 +304,7 @@ 303,"DG drain pump direction FPGA fault." 304,"HD invalid usage record." 305,"HD processor RAM error." - 306,"DG CD1 CD2 check fault." + 306,"Alarm ID available." 307,"HD AC power lost second alarm." 308,"DG CPi conductivity sensor invalid character received." 309,"DG CPo conductivity sensor invalid character received." @@ -321,4 +321,5 @@ 320,"DG chemical disinfect flush sample timeout." 321,"DG outlet UV reactor not healthy." 322,"HD UI POST Year check failure." - 323,"Total number of alarms." + 323,"HD UI POST Configuration check failure." + 324,"Total number of alarms."