Index: AlarmMapping.csv =================================================================== diff -u -rcd7956150072dcb5264c891ee363074623052ead -r2d0bacfbe1b70055247eb40743405a5f9acb15e3 --- AlarmMapping.csv (.../AlarmMapping.csv) (revision cd7956150072dcb5264c891ee363074623052ead) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision 2d0bacfbe1b70055247eb40743405a5f9acb15e3) @@ -5,10 +5,10 @@ 4,"HD Watchdog POST failure." 5,"DG Watchdog POST failure." 6,"UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." - 7,"Real-time clock configuration error." + 7,"Alarm ID available for use." 8,"HD accelerometer failed POST." 9,"DG accelerometer failed POST." - 10,"RTC or MCU timer inaccurate." + 10,"Alarm ID available for use." 11,"DG heaters failed POST." 12,"HD firmware image integrity POST test failed." 13,"DG firmware image integrity POST test failed." @@ -41,9 +41,9 @@ 40,"Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." 41,"Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." 42,"Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." - 43,"Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time." + 43,"Alarm ID available for use." 44,"User interface communication timeout." - 45,"Too many bad CRCs detected on received system messages." + 45,"HD too many bad communications CRC." 46,"System message that required acknowledgment was not acknowledged." 47,"Ultrafiltration rate is too high error during treatment." 48,"Ultrafiltration volume accuracy error during treatment." @@ -142,7 +142,7 @@ 141,"Air trap fill timeout during treatment." 142,"Blood pump occlusion detected." 143,"DG dialysate temperature sensors out of range." - 144,"DG software configuration record invalid CRC." + 144,"Alarm ID available for use." 145,"Concentrate conductivity after adding acid out of range alarm." 146,"DG RTC or timer accuracy failure." 147,"Wait for the DG to produce dialysate." @@ -153,7 +153,7 @@ 152,"Inlet water pressure in low range." 153,"HD prime completed high priority alarm." 154,"EEPROM operations (read, write, erase) failure." - 155,"DG software configuration record invalid CRC." + 155,"Alarm ID available for use." 156,"HW usage data (treatment time in HD and total consumed water in DG) failure." 157,"DG chemical disinfect prime acid line timeout." 158,"Inlet water temperature is in the low range." @@ -171,8 +171,8 @@ 170,"HD syringe empty alarm." 171,"HD syringe pump occlusion alarm." 172,"HD syringe pump not enough Heparin alarm." - 173,"HD arterial air bubble detected alarm." - 174,"HD arterial air bubble detected rinseback alarm." + 173,"HD RTC configuration error." + 174,"HD RTC or timer accuracy failure." 175,"HD pump direction status error." 176,"HD active reservoir is full during treatment and DG not ready to switch reservoirs." 177,"DG software fault.\nSoftware found itself in an unexpected state." @@ -196,7 +196,7 @@ 195,"DG RO pump pressure out of range." 196,"DG temperature sensor error flag fault." 197,"DG temperature sensors ADC fault." - 198,"DG heaters cold junction temperature out of range." + 198,"Alarm ID available for use." 199,"DG heaters fault." 200,"DG thermistors/sensors temperature out of range." 201,"HD pre-treatment mode wet self-test lc vs FMD failure." @@ -206,7 +206,7 @@ 205,"Conductivity sensor fault." 206,"DG dialysate fill runs out of time." 207,"DG flow meter check failure alarm." - 208,"DG primary heater on with no flow time out." + 208,"Alarm ID available for use." 209,"DG drain circulation line timeout." 210,"HD battery pack detected an error." 211,"Blood sitting too long warning (>4 min)." @@ -231,7 +231,7 @@ 230,"HD prime dialysate bypass time out alarm." 231,"HD pre-treatment mode dry pressure self-test failure." 232,"HD pre-treatment mode wet self-test LC vs LC failure." - 233,"RTC battery low." + 233,"Alarm ID available for use." 234,"RTC (i.e read time) or RAM operations failure (read or write)." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." 236,"HD needs new cartridge to be installed." @@ -286,7 +286,7 @@ 285,"HD treatment recirculate timeout warning." 286,"HD treatment rinseback complete timeout warning." 287,"HD processor clock speed checks against FPGA clock failure." - 288,"DG trimmer heater on with flow timeout." + 288,"Alarm ID available for use." 289,"DG dialysate or concentrate caps not closed." 290,"DG flow too low while heater is on." 291,"Total number of alarms."