Index: AlarmMapping.csv =================================================================== diff -u -rcf61c7736f11f4b75a4e2df803f29bdc7769db53 -r9891a1deb940324058d295bcd3ff5e55c47701c2 --- AlarmMapping.csv (.../AlarmMapping.csv) (revision cf61c7736f11f4b75a4e2df803f29bdc7769db53) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision 9891a1deb940324058d295bcd3ff5e55c47701c2) @@ -45,7 +45,7 @@ 44,"HD UI communication timeout." 45,"HD too many bad communications CRC." 46,"HD didn't get ACK on message to UI that required acknowledgment." - 47,"Available for use." + 47,"DG maximum RO Pump PWM exceeded." 48,"HD ultrafiltration volume accuracy error during treatment." 49,"HD FPGA communication down for too long." 50,"DG FPGA not accepting commanded valve states." @@ -61,7 +61,7 @@ 60,"HD valve not functional." 61,"HD valve current out of range." 62,"HD valve position out of target." - 63,"HD blood leak FPGA fault." + 63,"HD syringe pump prime timeout." 64,"DG barometric pressure sensor out of range." 65,"HD DG requests DG command with invalid parameter fault." 66,"HD blood leak sensor set point set failure." @@ -90,15 +90,15 @@ 89,"DG outlet UV reactor on with no flow." 90,"DG load cells A1/B1 FPGA fault." 91,"HD No dialysate flow data receive in the last 3 seconds." - 92,"Available for use." + 92,"DG temperature sensors invalid calibration record." 93,"DG outlet primary conductivity out of range." 94,"DG pressure out of range." 95,"DG watchdog expired." 96,"DG inlet water temperature in high range." 97,"DG fill conductivity out of range." 98,"HD battery communication fault." 99,"HD syringe pump stall alarm." - 100,"HD no cartridge self-test timeout." + 100,"DG conductivity sensors invalid temperature compensation calibration record." 101,"UI POST HD communication failure." 102,"DG heat disinfect temperature gradient out of range." 103,"HD invalid calibration CRC." @@ -127,7 +127,7 @@ 126,"HD blood leak detected alarm." 127,"HD venous pressure too low during treatment." 128,"HD venous air bubble detected alarm." - 129,"Available for use." + 129,"HD blood leak recovering please wait." 130,"HD venous pressure too high during treatment." 131,"HD arterial pressure too low during treatment." 132,"HD arterial pressure too high during treatment." @@ -164,17 +164,17 @@ 163,"HD sees primary load cell for reservoir 1 change too much too fast." 164,"HD sees primary load cell for reservoir 2 change too much too fast." 165,"HD in treatment rinseback operation timeout." - 166,"Available for use." + 166,"Test alarm, clear top only." 167,"HD cartridge door opened alarm." - 168,"Available for use." + 168,"Test alarm, clear top only." 169,"DG Dialysate flow rate out of maximum range." 170,"HD syringe empty alarm." 171,"HD syringe pump occlusion alarm." 172,"HD syringe pump not enough Heparin alarm." 173,"HD RTC configuration error." 174,"HD RTC or timer accuracy failure." 175,"HD pump direction status error." - 176,"HD dialysate temperature above high safety range." + 176,"Test alarm, clear top only." 177,"DG software fault.\nSoftware found itself in an unexpected state." 178,"HD communication timeout." 179,"DG FPGA communication down for too long." @@ -201,7 +201,7 @@ 200,"DG thermistors/sensors temperature out of range." 201,"HD pre-treatment mode wet self-test lc vs FMD failure." 202,"HD pre-treatment mode dry pressure normal self-test failure." - 203,"Available for use." + 203,"DG fill conductivities acid/bicarb invalid calibration record." 204,"DG RO rejection ratio out of range." 205,"DG conductivity sensor fault." 206,"DG dialysate fill runs out of time." @@ -235,7 +235,7 @@ 234,"DG inlet water pressure in high range." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." 236,"HD needs new cartridge to be installed." - 237,"HD prime saline dialyzer time out alarm." + 237,"Available for use." 238,"HD no cartridge loaded or installed improperly alarm." 239,"HD fail to remove cartridge alarm." 240,"DG bicarb conductivity out of range during bicarb pump check alarm." @@ -256,11 +256,11 @@ 255,"HD and UI software builds are not compatible." 256,"HD processor is in Disinfect Chemical Flush mode." 257,"Alarm ID available for use." - 258,"Alarm Id available." + 258,"HD UI POST OS version compatibility failure." 259,"HD temperatures out of range." 260,"HD UI POST Application Integrity (Sha256Sum) failure." 261,"HD UI POST CANBus failure." - 262,"HD UI POST Display failure." + 262,"Alarm Id available." 263,"HD UI POST Touch failure." 264,"HD UI POST SD-Card failure." 265,"HD UI POST RTC failure." @@ -272,7 +272,7 @@ 271,"DG POST Safety Shutdown failure." 272,"HD Fan RPM out of range." 273,"Available for use." - 274,"Available for use." + 274,"DG inactive reservoir weight out of range." 275,"HD arterial pressure sensor is reading out of range." 276,"HD venous pressure sensor is reading out of range." 277,"HD BP occlusion sensor is reading out of range." @@ -283,7 +283,7 @@ 282,"Bicarbonate concentration bottle low volume alarm." 283,"DG load cells weight out of range." 284,"DG load cells primary/back up drift out of range." - 285,"Available for use." + 285,"HD processor is in RO permeate sample mode." 286,"DG concentrate cap not in proper position." 287,"HD processor clock speed checks against FPGA clock failure." 288,"HD load cells primary/back up drift out of range." @@ -292,7 +292,7 @@ 291,"HD processor is in Disinfect Flush mode." 292,"HD processor is in Disinfect Heat mode." 293,"HD processor is in Disinfect Chemical mode." - 294,"Available for use." + 294,"HD processor is in Disinfect active cool mode." 295,"HD UI POST CloudSync failure." 296,"DG TDi sensors FPGA fault." 297,"DG TRo sensors FPGA fault." @@ -304,7 +304,7 @@ 303,"DG drain pump direction FPGA fault." 304,"HD invalid usage record." 305,"HD processor RAM error." - 306,"DG CD1 CD2 check fault." + 306,"Alarm ID available." 307,"HD AC power lost second alarm." 308,"DG CPi conductivity sensor invalid character received." 309,"DG CPo conductivity sensor invalid character received." @@ -321,4 +321,5 @@ 320,"DG chemical disinfect flush sample timeout." 321,"DG outlet UV reactor not healthy." 322,"HD UI POST Year check failure." - 323,"Total number of alarms." + 323,"HD UI POST Configuration check failure." + 324,"Total number of alarms."