Index: resources/settings/Instructions/Instructions.conf =================================================================== diff -u -ra64c31ec79b3af203691f70397cc31f5727f47f4 -r7077e38c74db9cccb5496ffefcf8936c0916de76 --- resources/settings/Instructions/Instructions.conf (.../Instructions.conf) (revision a64c31ec79b3af203691f70397cc31f5727f47f4) +++ resources/settings/Instructions/Instructions.conf (.../Instructions.conf) (revision 7077e38c74db9cccb5496ffefcf8936c0916de76) @@ -1,10 +1,61 @@ +[Sample^Water Sample] +Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = water sampling_v2.png + +[Sample^Water Sample Result] +Test the water sample per your clinic's instructions and enter the result. = temp_water_test.png + +[Sample^Water Sample Result Failed] +Water sample result failed. = logo.png + +[Consumables^Consumables Installation] +Open the DG concentrate door. = concentrate door open-v1.png +Remove the bottom acid/bicarbonate cap. = remove Acid_Bicab cap-v2.png +Connect the acid concentrate to the acid port. = Acid line connect v2.png +Connect the bicarbonate concentrate to the bicarbonate port. = Bicarb line connect v2.png + [Disposables^Cartridge Installation] -Unlock pump track, Lock pump track =1.png -Insert cartridge using alignment pins =2.png -HD machine door open / HD machine door closed =3.png +Open the front panel door. = door up v2.png +Unlock the pump track by moving the lever to its upward position. = pump track lock_v1.png +Install the cartirdge using the aligment pins. = cassette load_v1.png +Lock the pump track by moving the lever to its downward position. = cassette clamp lock v2-01.png [Disposables^Cartridge Connection] -Connect dialyzer v1 = slide2_filter-connect_v1.png +Insert dialyzer into the clamps. = filter load_72.png +Connect the cartridge dialysis fluid and blood lines to the the dialyzer. = filter connect_72.png +Connect the cartridge tubing line to air vent port. Unclamp the pinch clamp. = PBo connect_72.png +Remove the top dialysis fluid cap. = remove top cap v1.png +Connect the cartridge dialysis fluid lines to the DG fluid ports. = Dialysate lines to DG v2.png -[Sample^Water Sample] -Please follow the instruction to sample the water = water sampling_v1.png +[Disposables^Heparin Syringe] +Fill a syringe with heparin (1000 units/mL) and connect the cartridge heparin tubing line. = syringe connect_72.png +Insert syringe into infusion pump housing. = syringe load_72.png + +[Disposables^Saline Bag] +Spike a saline bag and connect it to the cartridge tubing. Hang the saline bag on the hook. = saline connect_72.png + +[Connection^Patient Connection] +Establish vascular access per your clinic's instructions. +Clamp lines and remove arterial and venous shunt. = untwist stunt_72.png +Connect arterial and venous cartridge lines to your patient access lines. = alt connect fistula_72.png + +[Connection^Start Treatment] +Unclamp patient lines and cartridge lines.= + +[Disconnection^Patient Disconnection] +Patient Disconnection=logo.png + +[Disposables^Disposables Removal] +Disposables Removal1=logo.png +Disposables Removal2=logo.png + +[Disinfection^Disinfection] +Disinfection1=logo.png +Disinfection2=logo.png +Disinfection3=logo.png + +[Chemical Disinfect^Chemical Disinfect] +Disinfection1=logo.png + + + +