Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r55cf0da75df38c83b25be1505c52b6ba4219fae9 -rfe7605e216422cd8a9e39eca7cc609730a56fa32 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 55cf0da75df38c83b25be1505c52b6ba4219fae9) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision fe7605e216422cd8a9e39eca7cc609730a56fa32) @@ -7,7 +7,7 @@ * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour - * \date (last) 04-Mar-2022 + * \date (last) 07-Mar-2022 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * @@ -150,10 +150,10 @@ /*0114*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } /* 114*/ /*0115*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor out of range." ); break; } /* 115*/ /*0116*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor ADC out of range." ); break; } /* 116*/ -/*0117*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heater internal temperature out of range." ); break; } /* 117*/ -/*0118*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATER_CJ_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heater cold junction temperature out of range." ); break; } /* 118*/ -/*0119*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater internal temperature out of range." ); break; } /* 119*/ -/*0120*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_CJ_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater cold junction temperature out of range." ); break; } /* 120*/ +/*0117*/case GuiAlarmID::ALARM_ID____AVAILABLE_28 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 117*/ +/*0118*/case GuiAlarmID::ALARM_ID____AVAILABLE_29 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 118*/ +/*0119*/case GuiAlarmID::ALARM_ID____AVAILABLE_30 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 119*/ +/*0120*/case GuiAlarmID::ALARM_ID____AVAILABLE_31 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 120*/ /*0121*/case GuiAlarmID::ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG main primary heater voltage out of range." ); break; } /* 121*/ /*0122*/case GuiAlarmID::ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG small primary heater voltage out of range." ); break; } /* 122*/ /*0123*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater voltage out of range." ); break; } /* 123*/ @@ -176,7 +176,7 @@ /*0140*/case GuiAlarmID::ALARM_ID_DG_COMM_TIMEOUT : { result = QObject::tr("Dialysate generator communication timeout." ); break; } /* 140*/ /*0141*/case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } /* 141*/ /*0142*/case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } /* 142*/ -/*0143*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT : { result = QObject::tr("DG dialysate temperature sensors drift timeout." ); break; } /* 143*/ +/*0143*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT : { result = QObject::tr("DG dialysate temperature sensors drift timeout." ); break; } /* 143*/ /*0144*/case GuiAlarmID::ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC : { result = QObject::tr("DG software configuration record invalid CRC." ); break; } /* 144*/ /*0145*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } /* 145*/ /*0146*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } /* 146*/ @@ -194,8 +194,8 @@ /*0158*/case GuiAlarmID::ALARM_ID____AVAILABLE_24 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 158*/ /*0159*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed flow vs motor speed check." ); break; } /* 159*/ /*0160*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH : { result = QObject::tr("Blood pump rotor speed too high." ); break; } /* 160*/ -/*0161*/case GuiAlarmID::ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Blood flow sensor signal strength too low." ); break; } /* 161*/ -/*0162*/case GuiAlarmID::ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Dialysate flow sensor signal strength too low." ); break; } /* 162*/ +/*0161*/case GuiAlarmID::ALARM_ID____AVAILABLE_26 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 161*/ +/*0162*/case GuiAlarmID::ALARM_ID____AVAILABLE_27 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 162*/ /*0163*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } /* 163*/ /*0164*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 2 change too much too fast." ); break; } /* 164*/ /*0165*/case GuiAlarmID::ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment rinseback operation timeout." ); break; } /* 165*/