Index: AlarmDefs.h =================================================================== diff -u -r17e260f451a5bc53c4d3d0724cfed4d32a1fb92c -r691732c7a9bcf0e3618d988ac66e663afdac8936 --- AlarmDefs.h (.../AlarmDefs.h) (revision 17e260f451a5bc53c4d3d0724cfed4d32a1fb92c) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 691732c7a9bcf0e3618d988ac66e663afdac8936) @@ -125,7 +125,7 @@ ALARM_ID_DG_HEATING_INVALID_CAL_RECORD = 87, ///< DG heating invalid calibration record ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE = 88, ///< DG concentrate pumps hall sensor out of range ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR = 89, ///< HD BP occlusion sensor error - ALARM_ID____AVAILABLE_25 = 90, ///< This alarm ID is available for use + ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT = 90, ///< DG dialysate temperature sensor drift timeout. ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE = 91, ///< HD No dialysate flow data receive in the last 3 seconds ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS = 92, ///< DG conductivity sensor bad status. ALARM_ID____AVAILABLE_15 = 93, ///< This alarm ID is available for use @@ -535,9 +535,9 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_25, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_15, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_16, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_17, 0, ALARM_ID_NO_ALARM }, @@ -595,12 +595,12 @@ { ALARM_PRIORITY_HIGH, 22, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 23, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 24, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 26, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 28, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To - { ALARM_PRIORITY_HIGH, 30, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 32, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 34, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_PRESSURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_PRESSURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 36, FALSE, FALSE, FALSE, TRUE, FALSE, TRUE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_HIGH, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC, 0, ALARM_ID_NO_ALARM }, @@ -654,9 +654,9 @@ { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_BAD_INLET_WATER_QUALITY, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INLET_WATER_PRESSURE_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_PRIMARY_HEATER_ON_WITH_NO_FLOW_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT, 0, ALARM_ID_NO_ALARM }, @@ -848,7 +848,7 @@ { 3, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD }, { 3, ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE }, { 3, ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR }, - { 3, ALARM_ID____AVAILABLE_25 }, + { 3, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT }, { 3, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE }, { 3, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS }, { 3, ALARM_ID____AVAILABLE_15 }, @@ -909,6 +909,13 @@ { 3, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, { 3, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT }, { 3, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT }, + { 3, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY }, + { 3, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY }, + { 3, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, + { 3, ALARM_ID_INLET_WATER_LOW_TEMPERATURE }, + { 3, ALARM_ID_INLET_WATER_LOW_PRESSURE }, + { 3, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, { 4, ALARM_ID_END_OF_TREATMENT_HIGH }, { 5, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 6, ALARM_ID_HD_BLOOD_LEAK_DETECTED }, @@ -933,11 +940,6 @@ { 22, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 23, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE }, { 24, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT }, - { 26, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, - { 28, ALARM_ID_INLET_WATER_LOW_TEMPERATURE }, - { 30, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY }, - { 32, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY }, - { 34, ALARM_ID_INLET_WATER_LOW_PRESSURE }, { 36, ALARM_ID_PRIME_COMPLETED_HIGH }, { 799, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE }, { 799, ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC }, @@ -985,9 +987,7 @@ { 799, ALARM_ID_DG_BAD_INLET_WATER_QUALITY }, { 799, ALARM_ID_INLET_WATER_PRESSURE_FAULT }, { 799, ALARM_ID_PRESSURE_SENSOR_FAULT }, - { 799, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, { 799, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT }, - { 799, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, { 799, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE }, { 799, ALARM_ID_DG_PRIMARY_HEATER_ON_WITH_NO_FLOW_TIMEOUT }, { 799, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT },