Index: AlarmDefs.h =================================================================== diff -u -r332637491b7c39fcf5275a8587cd3f32e6b2dbbe -r5550d0b88a5c5686b920ce0f71e60eb9e3e214b6 --- AlarmDefs.h (.../AlarmDefs.h) (revision 332637491b7c39fcf5275a8587cd3f32e6b2dbbe) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 5550d0b88a5c5686b920ce0f71e60eb9e3e214b6) @@ -592,7 +592,7 @@ { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_OCCLUSION_BLOOD_PUMP, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 21, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 21, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 22, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 23, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 24, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, TRUE, FALSE, ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 26, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, @@ -691,7 +691,7 @@ { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_NO_CARTRIDGE_LOADED, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT, 0, ALARM_ID_NO_ALARM }, @@ -907,6 +907,8 @@ { 3, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT }, { 3, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, { 3, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, + { 3, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, + { 3, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, { 4, ALARM_ID_END_OF_TREATMENT_HIGH }, { 5, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 6, ALARM_ID_HD_BLOOD_LEAK_DETECTED }, @@ -928,7 +930,6 @@ { 21, ALARM_ID_OCCLUSION_BLOOD_PUMP }, { 21, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT }, { 21, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC }, - { 22, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 23, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE }, { 24, ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT }, { 26, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, @@ -1026,7 +1027,6 @@ { 999, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT }, { 999, ALARM_ID_NO_CARTRIDGE_LOADED }, { 999, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, - { 999, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, { 999, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT }, { 999, ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT }, { 999, ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT },