Index: AlarmDefs.h =================================================================== diff -u -ree17eef29b21a9bb1546435aa331754f688c2744 -ra9cdf68e33d2d78ac3298bbd72a5b654e82a02f2 --- AlarmDefs.h (.../AlarmDefs.h) (revision ee17eef29b21a9bb1546435aa331754f688c2744) +++ AlarmDefs.h (.../AlarmDefs.h) (revision a9cdf68e33d2d78ac3298bbd72a5b654e82a02f2) @@ -341,7 +341,7 @@ ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT = 303, ///< DG drain pump direction FPGA fault ALARM_ID_HD_INVALID_USAGE_RECORD_CRC = 304, ///< HD invalid usage record ALARM_ID_HD_CPU_RAM_ERROR = 305, ///< HD processor RAM error - ALARM_ID_HD_AIR_TRAP_OVERFILL = 306, ///< HD air trap over-fill alarm + ALARM_ID___AVAILABLE_2 = 306, ///< ***Available for use*** ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT = 307, ///< HD AC power lost second alarm ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR = 308, ///< DG CPi conductivity sensor invalid character received ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR = 309, ///< DG CPo conductivity sensor invalid character received @@ -610,8 +610,8 @@ { ALARM_PRIORITY_HIGH, 5, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 6, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_BLOOD_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 8, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_VENOUS_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 9, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 10, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 9, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 10, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_VENOUS_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 12, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_ARTERIAL_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 13, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_ARTERIAL_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, @@ -623,7 +623,7 @@ { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_EXCESSIVE_TILT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 18, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AC_POWER_LOST, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 19, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_DG_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 20, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 20, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_OCCLUSION_BLOOD_PUMP, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_HIGH, 0, ALARM_ID_NO_ALARM }, @@ -794,7 +794,7 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_USAGE_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_CPU_RAM_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_HD_AIR_TRAP_OVERFILL, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID___AVAILABLE_2, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 18, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR, 0, ALARM_ID_NO_ALARM }, @@ -1026,7 +1026,7 @@ { 3, ALARM_ID_HD_CPU_RAM_ERROR }, { 3, ALARM_ID_HD_OCCLUSION_SENSOR_FPGA_FAULT }, { 3, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, - { 3, ALARM_ID_HD_AIR_TRAP_OVERFILL }, + { 3, ALARM_ID___AVAILABLE_2 }, { 3, ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR }, { 3, ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR }, { 3, ALARM_ID_DG_CD1_COND_SENSOR_INVALID_CHAR }, @@ -1469,7 +1469,7 @@ { 303 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG drain pump direction FPGA fault | If the FPGA indicates an error for a certain period of time. | "}, { 304 , ALARM_ID_HD_INVALID_USAGE_RECORD_CRC , "HD | Self-Test Error | Call service to schedule a repair. | HD invalid usage reocord | If the CRC of the HD usage record does not match the calculated CRC. | "}, { 305 , ALARM_ID_HD_CPU_RAM_ERROR , "HD | Processor RAM error | Call service to schedule a repair. | HD_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 306 , ALARM_ID_HD_AIR_TRAP_OVERFILL , "HD | Air Trap Error | Air Trap Error.\n- Check air trap fill level. | HD air trap overfill fault | If the air trap sensor reports upper level while HD is in treatment mode for a certain period of time. | "}, + { 306 , ALARM_ID___AVAILABLE_2 , "NA | Available | Available | HD air trap overfill fault | If the air trap sensor reports upper level while HD is in treatment mode for a certain period of time. | "}, { 307 , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT , "HD | HD AC power loss | HD power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, { 308 , ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR , "DG | Conductivity Sensors Error | Call service to schedule a repair. | DG CPi conductivity sensor transmits invalid characters | If the CPi conductivity sensor transmits invalid characters for a certain period of time. | "}, { 309 , ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR , "DG | Conductivity Sensors Error | Call service to schedule a repair. | DG CPo conductivity sensor transmits invalid characters | If the CPo conductivity sensor transmits invalid characters for a certain period of time. | "},