Index: MsgDefs.h =================================================================== diff -u -rd837a0536b52ba77ccd9dbb3471232a9fc50d02b -r8b3423d02f58a44bca8aa90dfa0ad42019727416 --- MsgDefs.h (.../MsgDefs.h) (revision d837a0536b52ba77ccd9dbb3471232a9fc50d02b) +++ MsgDefs.h (.../MsgDefs.h) (revision 8b3423d02f58a44bca8aa90dfa0ad42019727416) @@ -101,8 +101,8 @@ MSG_ID_UI_PRESSURE_LIMITS_CHANGE_REQUEST = 0x46, ///< UI request to change pressure limits MSG_ID_HD_PRESSURE_LIMITS_CHANGE_RESPONSE = 0x47, ///< HD response to change pressure limits request MSG_ID_DG_FANS_DATA = 0x48, ///< DG broadcast fans data - MSG_ID_HD_CALIBRATION_DATA = 0x49, ///< HD broadcast calibration data - MSG_ID_DG_CALIBRATION_DATA = 0x4A, ///< DG broadcast calibration data + MSG_ID___AVAILABLE_4 = 0x49, ///< This msg ID is available for use + MSG_ID___AVAILABLE_5 = 0x4A, ///< This msg ID is available for use MSG_ID_UI_HEPARIN_PAUSE_RESUME_REQUEST = 0x4B, ///< UI request to pause/resume Heparin delivery MSG_ID_HD_HEPARIN_PAUSE_RESUME_RESPONSE = 0x4C, ///< HD response to pause/resume Heparing delivery request MSG_ID_HD_HEPARIN_DATA_BROADCAST = 0x4D, ///< HD broadcast of Heparin delivery data @@ -169,9 +169,9 @@ MSG_ID_HD_ACCEL_OVERRIDE = 0x8027, ///< HD accelerometer sensor override request MSG_ID_HD_ACCEL_MAX_OVERRIDE = 0x8028, ///< HD accelerometer sensor max. override request MSG_ID_HD_ACCEL_SEND_INTERVAL_OVERRIDE = 0x8029, ///< HD accelerometer data broadcast interval override request - MSG_ID_HD_ACCEL_SET_CALIBRATION = 0x802A, ///< HD accelerometer set calibration factors request - MSG_ID_HD_BLOOD_FLOW_SET_CALIBRATION = 0x802B, ///< Blood flow set calibration factors request - MSG_ID_HD_DIALYSATE_FLOW_SET_CALIBRATION = 0x802C, ///< Dialysate flow set calibration factors request + MSG_ID___AVAILABLE_6 = 0x802A, ///< This msg ID is available for use + MSG_ID___AVAILABLE_7 = 0x802B, ///< This msg ID is available for use + MSG_ID___AVAILABLE_8 = 0x802C, ///< This msg ID is available for use MSG_ID_HD_SET_PARAMETER_TREATMENT_PARAMETER = 0x802D, ///< Set a treatment parameter (will change actual setting, not an override) MSG_ID_HD_VALVES_HOME = 0x802E, ///< Home an HD Valve MSG_ID_HD_VALVES_POSITION_OVERRIDE = 0x802F, ///< Set an HD valve to a position in counts @@ -186,8 +186,8 @@ MSG_ID_DIAL_IN_PUMP_HOME_CMD = 0x8038, ///< Dialysate inlet pump home command MSG_ID_DIAL_OUT_PUMP_HOME_CMD = 0x8039, ///< Dialysate outlet pump home command MSG_ID_SUPER_CLEAR_ALARMS_CMD = 0x803A, ///< Clears all alarms (even if non-recoverable or fault) - MSG_ID_HD_REQUEST_CALIBRATION_DATA = 0x803B, ///< Requests calibration data from HD TODO REMOVE - MSG_ID_HD_ERASE_CALIBRATION_DATA = 0x803C, ///< Requests calibration data on HD be erased TODO REMOVE + MSG_ID___AVAILABLE_9 = 0x803B, ///< This msg ID is available for use + MSG_ID___AVAILABLE_10 = 0x803C, ///< This msg ID is available for use MSG_ID_HD_SET_CALIBRATION_RECORD = 0x803D, ///< HD set calibration record that is received from Dialin MSG_ID_HD_GET_CALIBRATION_RECORD = 0x803E, ///< HD get calibration record that is requested from Dialin MSG_ID_HD_SEND_CALIBRATION_RECORD = 0x803F, ///< HD send calibration record to CAN bus to be received in Dialin (equivalent to publish)