Index: AlarmDefs.h =================================================================== diff -u -r2286870bb6faeaaed144b43e7f1af253ba0e3689 -r0cb1008e8419fb38d89ca2ebcbff68d8141bd111 --- AlarmDefs.h (.../AlarmDefs.h) (revision 2286870bb6faeaaed144b43e7f1af253ba0e3689) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 0cb1008e8419fb38d89ca2ebcbff68d8141bd111) @@ -64,7 +64,11 @@ ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD, ///< HD accelerometer invalid calibration record ALARM_ID_HD_BLOOD_FLOW_INVALID_CAL_RECORD, ///< HD blood flow invalid calibration record ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CAL_RECORD, ///< HD dialyzer flow invalid calibration record - ALARM_ID_HD_HEPARING_FORCE_SENSOR_INVALID_CAL_RECORD, ///< HD heparin force sensor invalid calibration record + ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD, ///< HD heparin force sensor invalid calibration record + ALARM_ID_HD_INVALID_SYSTEM_RECORD, ///< HD invalid system record + ALARM_ID_HD_INVALID_SERVICE_RECORD, ///< HD invalid service record + ALARM_ID_DG_INVALID_SYSTEM_RECORD, ///< DG invalid sytem record + ALARM_ID_DG_INVALID_SERVICE_RECORD, ///< DG invalid service record ALARM_ID_HD_SOFTWARE_FAULT, ///< HD Software fault. Software found itself in an unexpected state ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK, ///< Blood pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running ALARM_ID_BLOOD_PUMP_OFF_CHECK, ///< Blood pump failed motor off check. Measured speed while commanded off @@ -425,7 +429,11 @@ { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_BLOOD_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_HEPARING_FORCE_SENSOR_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_DG_INVALID_SYSTEM_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_DG_INVALID_SERVICE_RECORD, 0, ALARM_ID_NO_ALARM }, // Machine fault high priority alarms { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_HD_SOFTWARE_FAULT, 0, ALARM_ID_NO_ALARM },