Index: firmware/App/Services/Reservoirs.c =================================================================== diff -u -r84989e158824d6cc8d8747ca80c6419315cc951c -r581064e4188c15307a70bc4265974d61dea23ff8 --- firmware/App/Services/Reservoirs.c (.../Reservoirs.c) (revision 84989e158824d6cc8d8747ca80c6419315cc951c) +++ firmware/App/Services/Reservoirs.c (.../Reservoirs.c) (revision 581064e4188c15307a70bc4265974d61dea23ff8) @@ -175,7 +175,8 @@ getNVRecord2Driver( GET_CAL_HEATING_RECORD, (U08*)&heatingConstsCalRecord, sizeof( heatingConstsCalRecord ), NUM_OF_CAL_DATA_RSRVRS, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD ); - getNVRecord2Driver( GET_CAL_FILL_CONDUCTIVITIES_RECORD, (U08*)&fillCondCalRecord, sizeof( fillCondCalRecord ), 0, ALARM_ID_NO_ALARM ); + getNVRecord2Driver( GET_CAL_FILL_CONDUCTIVITIES_RECORD, (U08*)&fillCondCalRecord, sizeof( fillCondCalRecord ), + NUM_OF_ACID_TYPE, ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD ); } // If the mode is fault or it is standby and the RO volume has not been written already, write it @@ -225,7 +226,8 @@ calStatus |= getNVRecord2Driver( GET_CAL_BICARB_CONCENTRATES, (U08*)&bicarbConcentrateCalRecord, sizeof( bicarbConcentrateCalRecord ), NUM_OF_ACID_AND_BICARB_NV_DATA_TO_CHECK, ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD ); - calStatus |= getNVRecord2Driver( GET_CAL_FILL_CONDUCTIVITIES_RECORD, (U08*)&fillCondCalRecord, sizeof( fillCondCalRecord ), 0, ALARM_ID_NO_ALARM ); + calStatus |= getNVRecord2Driver( GET_CAL_FILL_CONDUCTIVITIES_RECORD, (U08*)&fillCondCalRecord, sizeof( fillCondCalRecord ), + NUM_OF_ACID_TYPE, ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD ); if ( TRUE == calStatus ) {