Index: firmware/App/Controllers/ConductivitySensors.c =================================================================== diff -u -rbc85a63a8b467a0d65328dfb689695590d5f2097 -rff489c668da0650496eef9d85ac327dd38498f2d --- firmware/App/Controllers/ConductivitySensors.c (.../ConductivitySensors.c) (revision bc85a63a8b467a0d65328dfb689695590d5f2097) +++ firmware/App/Controllers/ConductivitySensors.c (.../ConductivitySensors.c) (revision ff489c668da0650496eef9d85ac327dd38498f2d) @@ -316,11 +316,9 @@ /*********************************************************************//** * @brief * The checkInletWaterConductivity function checks inlet water conductivity value - * and triggers an alarm when conductivity value is not within the specified - * values. + * and triggers an alarm when conductivity value is out of allowed range. * @details Inputs: CPi sensor conductivity - * @details Outputs: Trigger warning alarm if conductivity is in the warning - * range. Trigger alarm if conductivity is below minimum conductivity. + * @details Outputs: Trigger alarms when conductivity is out of allowed range * @return none *************************************************************************/ void checkInletWaterConductivity( void ) Index: firmware/App/Modes/ModeFill.c =================================================================== diff -u -r8c24d29d5a1c0b85067d67054fee2718d425bf47 -rff489c668da0650496eef9d85ac327dd38498f2d --- firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision 8c24d29d5a1c0b85067d67054fee2718d425bf47) +++ firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision ff489c668da0650496eef9d85ac327dd38498f2d) @@ -78,7 +78,7 @@ // 2m long tubing to cap = 19.5 mL (acid line) + 7.92 mL/m * 2 m (tubing to cap) + 20.82 mL (straw) = 56.15 mL // Prime time in seconds = ( 56.15 mL / 48 mL/min ) x 60 second/min + 25 seconds margin time = 95 seconds. -#define PRIME_CONCENTRATE_LINES_TIME_OUT_MS ( 95 * MS_PER_SECOND ) ///< Time required to prime the concentrate lines. +#define PRIME_CONCENTRATE_LINES_TIME_OUT_MS ( 60 * MS_PER_SECOND ) ///< Time required to prime the concentrate lines. #define FLUSH_BUBBLES_PUMP_TIME_OUT_MS ( 2 * MS_PER_SECOND ) ///< RO pump on during flush bubble interval in ms. #define DIALYSATE_TEMPERATURE_TOLERANCE_C 2.0F ///< Dialysate temperature tolerance in degree C. #define DATA_PUBLISH_COUNTER_START_COUNT 63 ///< Data publish counter start count. @@ -615,7 +615,7 @@ requestConcentratePumpOn( CONCENTRATEPUMPS_CP2_BICARB ); // Prior to collecting data for bicarb test, change the CD2 calibration table - setCondcutivitySensorCalTable( CONDUCTIVITYSENSORS_CD2_SENSOR, CAL_DATA_CD2_COND_SENSOR_FILL_BICARB_TEST ); + // setCondcutivitySensorCalTable( CONDUCTIVITYSENSORS_CD2_SENSOR, CAL_DATA_CD2_COND_SENSOR_FILL_BICARB_TEST ); // TODO uncomment // State transition concentrateTestStartTime = getMSTimerCount(); Index: firmware/App/Services/AlarmMgmtSWFaults.h =================================================================== diff -u -r98059a6eef9f17d8178821f6a1fa0db44415cf7f -rff489c668da0650496eef9d85ac327dd38498f2d --- firmware/App/Services/AlarmMgmtSWFaults.h (.../AlarmMgmtSWFaults.h) (revision 98059a6eef9f17d8178821f6a1fa0db44415cf7f) +++ firmware/App/Services/AlarmMgmtSWFaults.h (.../AlarmMgmtSWFaults.h) (revision ff489c668da0650496eef9d85ac327dd38498f2d) @@ -85,8 +85,8 @@ SW_FAULT_ID_PERSISTENT_ALARM_INVALID_INDEX, SW_FAULT_ID_CONCENTRATE_PUMP_EXEC_INVALID_STATE, // 55 SW_FAULT_ID_CONCENTRATE_PUMP_INVALID_PUMP_ID, - SW_FAULT_ID_SEMAPHORE_IN_USE_TIMEOUT, SW_FAULT_ID_SERVICE_MODE_INVALID_EXEC_STATE, + SW_FAULT_ID_SEMAPHORE_IN_USE_TIMEOUT, SW_FAULT_ID_UV_REACTORS_INVALID_EXEC_STATE, SW_FAULT_ID_UV_REACTORS_INVALID_SELF_TEST_STATE, // 60 SW_FAULT_ID_THERMISTORS_INVALID_EXEC_STATE,