Index: dialin/common/hd_defs.py =================================================================== diff -u -r8ff49bb248b9b98b18dde057d836b5c2d308922c -r4c196bf0092414737023812b5bda5defab3f5ba4 --- dialin/common/hd_defs.py (.../hd_defs.py) (revision 8ff49bb248b9b98b18dde057d836b5c2d308922c) +++ dialin/common/hd_defs.py (.../hd_defs.py) (revision 4c196bf0092414737023812b5bda5defab3f5ba4) @@ -196,13 +196,14 @@ class PreTreatmentModeStates(DialinEnum): HD_PRE_TREATMENT_START_STATE = 0 # Start pre-treatment mode state HD_PRE_TREATMENT_WATER_SAMPLE_STATE = 1 # Water sample state - HD_PRE_TREATMENT_SELF_TEST_NO_CART_STATE = 2 # Self tests with no cartridge state - HD_PRE_TREATMENT_CART_INSTALL_STATE = 3 # Consumable and cartridge installation state - HD_PRE_TREATMENT_SELF_TEST_DRY_STATE = 4 # Self tests dry state - HD_PRE_TREATMENT_PRIME_STATE = 5 # Prime blood and dialysate circuits and run wet self-tests state - HD_PRE_TREATMENT_RECIRCULATE_STATE = 6 # Re-circulate blood and dialysate circuits state - HD_PRE_TREATMENT_PATIENT_CONNECTION_STATE = 7 # Patient connection state - NUM_OF_HD_PRE_TREATMENT_STATES = 8 # Number of pre-treatment mode states + HD_PRE_TREATMENT_SELF_TEST_CONSUMABLE_STATE = 2 # Consumable self-tests state + HD_PRE_TREATMENT_SELF_TEST_NO_CART_STATE = 3 # Self tests with no cartridge state + HD_PRE_TREATMENT_CART_INSTALL_STATE = 4 # Consumable and cartridge installation state + HD_PRE_TREATMENT_SELF_TEST_DRY_STATE = 5 # Self tests dry state + HD_PRE_TREATMENT_PRIME_STATE = 6 # Prime blood and dialysate circuits and run wet self-tests state + HD_PRE_TREATMENT_RECIRCULATE_STATE = 7 # Re-circulate blood and dialysate circuits state + HD_PRE_TREATMENT_PATIENT_CONNECTION_STATE = 8 # Patient connection state + NUM_OF_HD_PRE_TREATMENT_STATES = 9 # Number of pre-treatment mode states @unique @@ -270,12 +271,14 @@ HD_PRIME_SALINE_CIRC_BLOOD_CIRCUIT_STATE = 4 # Circulate blood circuit state HD_PRIME_RESERVOIR_ONE_FILL_COMPLETE_STATE = 5 # Wait for reservoir 1 fill complete HD_PRIME_DIALYSATE_DIALYZER_STATE = 6 # Dialysate dialyzer fluid path state - HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE = 7 # Wait for reservoir 2 fill complete - HD_PRIME_DIALYSATE_BYPASS_STATE = 8 # Dialysate bypass fluid path state - HD_PRIME_WET_SELF_TESTS_STATE = 9 # Perform wet self-tests after priming complete - HD_PRIME_PAUSE = 10 # Prime pause state = waits to be resumed - HD_PRIME_COMPLETE = 11 # Prime complete state - NUM_OF_HD_PRIME_STATES = 12 # Number of prime sub-mode states + HD_PRIME_SALINE_DIALYZER_SETUP_STATE = 7 # Saline dialyzer setup state + HD_PRIME_SALINE_DIALYZER_STATE = 8 # Saline dialyzer fluid path state + HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE = 9 # Wait for reservoir 2 fill complete + HD_PRIME_DIALYSATE_BYPASS_STATE = 10 # Dialysate bypass fluid path state + HD_PRIME_WET_SELF_TESTS_STATE = 11 # Perform wet self-tests after priming complete + HD_PRIME_PAUSE = 12 # Prime pause state = waits to be resumed + HD_PRIME_COMPLETE = 13 # Prime complete state + NUM_OF_HD_PRIME_STATES = 14 # Number of prime sub-mode states @unique