Index: dialin/common/hd_defs.py =================================================================== diff -u -rab95fd4d07280a6af9a18956a4e55ac9d62823e2 -rd76a5f67ae6c9534c3a0e43d5bb7d8adc61ad9eb --- dialin/common/hd_defs.py (.../hd_defs.py) (revision ab95fd4d07280a6af9a18956a4e55ac9d62823e2) +++ dialin/common/hd_defs.py (.../hd_defs.py) (revision d76a5f67ae6c9534c3a0e43d5bb7d8adc61ad9eb) @@ -284,18 +284,20 @@ @unique class PreTreatmentDrySelfTestsStates(DialinEnum): - DRY_SELF_TESTS_START_STATE = 0 # Dry self-tests starting state - DRY_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE = 1 # Wait for door to close before executing self-tests - DRY_SELF_TESTS_USED_CARTRIDGE_CHECK_STATE = 2 # Used cartridge check dry self-test state - DRY_SELF_TESTS_OCCLUSION_SENSORS_STATE = 3 # Occlusion sensors dry self-test state - DRY_SELF_TESTS_PRESSURE_SENSORS_SETUP_STATE = 4 # Pressure sensors dry self-test setup valves and pump state - DRY_SELF_TESTS_PRESSURE_SENSORS_STATE = 5 # Pressure sensors verify pressure readings state - DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_STATE = 6 # Pressure sensors verify normal pressure readings state - DRY_SELF_TESTS_SYRINGE_PUMP_PRIME_STATE = 7 # Prime syringe pump state - DRY_SELF_TESTS_SYRINGE_PUMP_OCCLUSION_DETECTION_STATE = 8 # Occlusion detection state - DRY_SELF_TESTS_STOPPED_STATE = 9 # Dry self-test stopped state - DRY_SELF_TESTS_COMPLETE_STATE = 10 # Dry self-test complete state - NUM_OF_DRY_SELF_TESTS_STATES = 11 # Number of dry self-tests states + DRY_SELF_TESTS_START_STATE = 0 # Dry self-tests starting state + DRY_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE = 1 # Wait for door to close before executing self-tests + DRY_SELF_TESTS_USED_CARTRIDGE_CHECK_STATE = 2 # Used cartridge check dry self-test state + DRY_SELF_TESTS_OCCLUSION_SENSORS_STATE = 3 # Occlusion sensors dry self-test state + DRY_SELF_TESTS_PRESSURE_SENSORS_SETUP_STATE = 4 # Pressure sensors dry self-test setup valves and pump state + DRY_SELF_TESTS_PRESSURE_SENSORS_PRESSURIZED_STATE = 5 # Pressure sensors verify pressure readings state + DRY_SELF_TESTS_PRESSURE_SENSORS_DECAY_STATE = 6 # Pressure sensors verify pressure loss state + DRY_SELF_TESTS_PRESSURE_SENSORS_STABILITY_STATE = 7 # Pressure sensors verify pressure stability state + DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_STATE = 8 # Pressure sensors verify normal pressure readings state + DRY_SELF_TESTS_SYRINGE_PUMP_PRIME_STATE = 9 # Prime syringe pump state + DRY_SELF_TESTS_SYRINGE_PUMP_OCCLUSION_DETECTION_STATE = 10 # Occlusion detection state + DRY_SELF_TESTS_STOPPED_STATE = 11 # Dry self-test stopped state + DRY_SELF_TESTS_COMPLETE_STATE = 12 # Dry self-test complete state + NUM_OF_DRY_SELF_TESTS_STATES = 13 # Number of dry self-tests states @unique