Index: firmware/App/HDCommon.h =================================================================== diff -u -r29a2c3c7d7618489c0ada9f98e1d30226b455392 -r2a3a47ca90ad19851a30c52f6999a56d5f578783 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 29a2c3c7d7618489c0ada9f98e1d30226b455392) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 2a3a47ca90ad19851a30c52f6999a56d5f578783) @@ -43,37 +43,19 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests - #define DISABLE_UI_POST_TEST 1 // Disable the UI POSTh + #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // TODO convert the new configuration way -// #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // Implement // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // Implement // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode // Implement // #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor // Part of DVT build switch // #define USE_PBO_AS_PBA 1 // PBo readings used for PBA, PBo replaced with fixed pressure (100 mmHg) // Not needed -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks // Implement // TODO implemented CHECK THE LAST ONE -// #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // Implement // TODO implemented - #define SKIP_CAL_CHECK 1 // Implement -// #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // Not needed + #define SKIP_CAL_CHECK 1 // Implement TODO stays as a build switch until the calibration structure is updated -// #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest // Implement // TODO implemented - -// #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. // Implement // TODO implemented - #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // Implement -// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check // Implement - - #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms // Implement - #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute // Implement +// #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute // Implement // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps // Implement -// #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms // Implement // TODO implemented -// #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts // Implement - -// #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm // Implement // TODO implemented - #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms // Implement - - #include #include #endif