Index: firmware/App/HDCommon.h =================================================================== diff -u -r565ed0856be2fcf1443e3ec4cb8fe023b2c14db4 -r240e23ebbb15f0ecb1bd7415b1a07c805f2f46e9 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 565ed0856be2fcf1443e3ec4cb8fe023b2c14db4) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 240e23ebbb15f0ecb1bd7415b1a07c805f2f46e9) @@ -25,19 +25,20 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 5 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 0 +#define HD_VERSION_BUILD 9005 // ********** development build switches ********** // TODO - remove build switches before release #ifndef _RELEASE_ #ifndef _VECTORCAST_ +// #define BOARD_WITH_NO_HARDWARE 1 // #define RUN_WITHOUT_DG 1 // Run HD w/o DG // #define SIMULATE_UI 1 // Build w/o requirement that UI be there // #define TASK_TIMING_OUTPUT_ENABLED 1 // Re-purposes alarm lamp pins for task timing // #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio - #define SKIP_POST 1 // Skip POST tests - all pass -// #define LIMITED_NVDATA_CRC_CHECKS 1 // Only perform POST CRC checks on nv-data records that are implemented so far +// #define SKIP_POST 1 // Skip POST tests - all pass +// #define DONT_SKIP_NV_POST 1 #define DISABLE_AIR_TRAP_LEVELING 1 // Disable air trap level control // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves @@ -52,22 +53,23 @@ #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define DISABLE_CAL_CHECK 1 // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests - #define SKIP_CALIBRATION_TESTS 1 // Skip calibration tests // #define V1_5_SYSTEM 1 // Build for v1.5 system #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests - #define SKIP_CALIBRATION_TESTS 1 // Skip pre-treatment self-tests involving calibration #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests #define SKIP_UI_INTERACTION 1 // Skip UI interaction. // #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. + #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. + #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check #include #include