Index: firmware/App/HDCommon.h =================================================================== diff -u -r5cc3d018b1d6e0f0177a69d1e7108af13aaa240a -r708c23e585468515a8467d0056d712b2846b56da --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 5cc3d018b1d6e0f0177a69d1e7108af13aaa240a) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 708c23e585468515a8467d0056d712b2846b56da) @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 21 +#define HD_VERSION_BUILD 27 // ********** development build switches ********** @@ -64,20 +64,20 @@ #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest // #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg - #define SKIP_PRIMING 1 // Skip Pre-treatment Prime +// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests #define V2_0_SYSTEM 1 // Build for v2.0 system #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests - #define SKIP_UI_INTERACTION 1 // Skip UI interaction. +// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. - #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check - #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check - #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters - #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms +// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check +// #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check +// #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters +// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps