Index: firmware/App/HDCommon.h =================================================================== diff -u -rc7890e8beda1708d2dea0762dcc40ca5a12222e3 -r3cdfce9c1c4fa0fd205756eb458ac5d3bffc9045 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision c7890e8beda1708d2dea0762dcc40ca5a12222e3) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 3cdfce9c1c4fa0fd205756eb458ac5d3bffc9045) @@ -10,8 +10,8 @@ * @author (last) Sean Nash * @date (last) 12-Nov-2021 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -24,8 +24,8 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 -#define HD_VERSION_MICRO 5 -#define HD_VERSION_BUILD 25 +#define HD_VERSION_MICRO 0 +#define HD_VERSION_BUILD 115 // ********** development build switches ********** @@ -49,7 +49,7 @@ // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) - #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor +// #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks @@ -59,8 +59,8 @@ #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -79,6 +79,7 @@ #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests + #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm // Skip Pre-Treatment and get to treatment as soon as possible #define SKIP_UI_INTERACTION 1 // Skip UI interaction.