Index: firmware/App/HDCommon.h =================================================================== diff -u -rdc951a5c309a10b4087162eac591ea4ebb66f329 -r45c8673e865751f6660e97b51609e9f4bc222842 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision dc951a5c309a10b4087162eac591ea4ebb66f329) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 45c8673e865751f6660e97b51609e9f4bc222842) @@ -10,8 +10,8 @@ * @author (last) Dara Navaei * @date (last) 04-Jan-2022 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 31 +#define HD_VERSION_BUILD 182 // ********** development build switches ********** @@ -59,12 +59,12 @@ #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks #define DISABLE_ARTERIAL_PRESSURE_CHECK 1 // Do not error on arterial pressure out of range #define DISABLE_VENOUS_PRESSURE_CHECK 1 // Do not error on venous pressure out of range -// #define USE_PBO_AS_PBA 1 // PBo readings used for PBA, PBo replaced with fixed pressure (100 mmHg) + #define USE_PBO_AS_PBA 1 // PBo readings used for PBA, PBo replaced with fixed pressure (100 mmHg) // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -78,15 +78,16 @@ #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently -// #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps + #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms - #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test - #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm +// #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test +// #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm + #define IGNORE_SERVICE_RECORD_CRC 1 // Skip Pre-Treatment and get to treatment as soon as possible #define SKIP_UI_INTERACTION 1 // Skip UI interaction.