Index: firmware/App/Modes/ModeTreatmentParams.c =================================================================== diff -u -rf6b78d1fe6741043de38707211710ab0e8a08483 -r1f91b5a53bda942b0967817bbd5e68a499dbf816 --- firmware/App/Modes/ModeTreatmentParams.c (.../ModeTreatmentParams.c) (revision f6b78d1fe6741043de38707211710ab0e8a08483) +++ firmware/App/Modes/ModeTreatmentParams.c (.../ModeTreatmentParams.c) (revision 1f91b5a53bda942b0967817bbd5e68a499dbf816) @@ -1,14 +1,14 @@ /************************************************************************** * -* Copyright (c) 2020-2022 Diality Inc. - All Rights Reserved. +* Copyright (c) 2020-2023 Diality Inc. - All Rights Reserved. * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * * @file ModeTreatmentParams.c * * @author (last) Michael Garthwaite -* @date (last) 18-Feb-2022 +* @date (last) 19-Jan-2023 * * @author (original) Sean Nash * @date (original) 29-May-2020 @@ -59,9 +59,9 @@ { CRITICAL_DATA_TYPE_U32, {.uInt=60}, {.uInt=480}, {.uInt=240} }, // TREATMENT_PARAM_TREATMENT_DURATION { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=480}, {.uInt=0} }, // TREATMENT_PARAM_HEPARIN_PRE_STOP_TIME { CRITICAL_DATA_TYPE_U32, {.uInt=100}, {.uInt=300}, {.uInt=100} }, // TREATMENT_PARAM_SALINE_BOLUS_VOLUME - { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=3}, {.uInt=0} }, // TREATMENT_PARAM_ACID_CONCENTRATE + { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=2}, {.uInt=0} }, // TREATMENT_PARAM_ACID_CONCENTRATE { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=0}, {.uInt=0} }, // TREATMENT_PARAM_BICARB_CONCENTRATE - { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=4}, {.uInt=0} }, // TREATMENT_PARAM_DIALYZER_TYPE + { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=5}, {.uInt=0} }, // TREATMENT_PARAM_DIALYZER_TYPE { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=0}, {.uInt=0} }, // TREATMENT_PARAM_HEPARIN_TYPE { CRITICAL_DATA_TYPE_U32, {.uInt=0}, {.uInt=60}, {.uInt=30} }, // TREATMENT_PARAM_BP_MEAS_INTERVAL { CRITICAL_DATA_TYPE_U32, {.uInt=50}, {.uInt=150}, {.uInt=75} }, // TREATMENT_PARAM_RINSEBACK_FLOW_RATE @@ -170,6 +170,10 @@ stagedParams[ param ].uInt = 0; } + // NOTE: the syringe pump's monitor requires these two parameters to be set to 0 + setTreatmentParameterF32( TREATMENT_PARAM_HEPARIN_BOLUS_VOLUME, 0.0 ); + setTreatmentParameterF32( TREATMENT_PARAM_HEPARIN_DISPENSE_RATE, 0.0 ); + // Zero original parameter values origTreatmentParams.bloodFlowRate_mL_min = 0; origTreatmentParams.dialysateFlowRate_mL_min = 0; @@ -272,6 +276,7 @@ *************************************************************************/ U32 execTreatParamsMode( void ) { + HD_TREATMENT_PARAMS_MODE_STATE_T priorSubState = currentTreatmentParamsState; BOOL stop = isStopButtonPressed(); if ( TRUE == stop ) @@ -300,6 +305,11 @@ } + if ( priorSubState != currentTreatmentParamsState ) + { + SEND_EVENT_WITH_2_U32_DATA( HD_EVENT_SUB_STATE_CHANGE, priorSubState, currentTreatmentParamsState ); + } + return (U32)currentTreatmentParamsState; } @@ -714,7 +724,7 @@ memcpy( &respPayload[0], &reasons[0], sizeof(TREATMENT_PARAMS_DATA_PAYLOAD_T) ); - sendTreatmentParametersResponseMsg( accepted, (U08*)(&respPayload[0]), ( NUM_OF_TREATMENT_PARAMS - 1 ) * sizeof(U32) ); // UF vol. param not included in reject reasons + sendTreatmentParametersResponseMsg( accepted, (U08*)(&respPayload[0]), ( NUM_OF_TREATMENT_PARAMS - 1 ) ); // UF vol. param not included in reject reasons } /*********************************************************************//**