Index: firmware/App/Services/AlarmMgmt.h =================================================================== diff -u -rc3cf7af051c1ee070df90a9c072df16be48f478f -r6419179374edcd65da462de84e8aeaefb7e20320 --- firmware/App/Services/AlarmMgmt.h (.../AlarmMgmt.h) (revision c3cf7af051c1ee070df90a9c072df16be48f478f) +++ firmware/App/Services/AlarmMgmt.h (.../AlarmMgmt.h) (revision 6419179374edcd65da462de84e8aeaefb7e20320) @@ -81,7 +81,8 @@ BOOL noResume; ///< Treatment may not be resumed at this time BOOL noRinseback; ///< Rinseback may not be initiated at this time BOOL noEndTreatment; ///< Ending the treatment is not an option at this time - BOOL noNewTreatment; ///< No new treatments may be started even if current treatment is ended + BOOL noNewTreatment; ///< No new treatments may be started even if current treatment is ended + BOOL noDialRecirc; ///< No dialysate re-circulation allowed at this time BOOL usrACKRequired; ///< The user must acknowledge top alarm BOOL lampOn; ///< The alarm lamp is on } COMP_ALARM_STATUS_T; @@ -238,16 +239,23 @@ SW_FAULT_ID_MODE_PRE_TREATMENT_PRIME_INVALID_STATE, SW_FAULT_ID_SYSTEM_COMM_INVALID_FRAME_SIZE, SW_FAULT_ID_SYSTEM_CMMM_CAN_TRANSMIT_REJECTED, // 95 + SW_FAULT_ID_BLOOD_PRIME_INVALID_STATE, + SW_FAULT_ID_RINSEBACK_INVALID_STATE, + SW_FAULT_ID_TREATMENT_END_INVALID_STATE, + SW_FAULT_ID_TREATMENT_RECIRC_INVALID_STATE, + SW_FAULT_ID_TREATMENT_STOP_INVALID_STATE, // 100 + SW_FAULT_ID_MODE_PRIME_INVALID_ALARM_ACTION, + SW_FAULT_ID_INVALID_NVDATAMGMT_EXEC_CAL_STATE, SW_FAULT_ID_HD_INVALID_NO_CARTRIDGE_SELF_TEST_STATE, SW_FAULT_ID_HD_INVALID_DRY_SELF_TEST_STATE, - SW_FAULT_ID_HD_INVALID_WET_SELF_TEST_STATE, + SW_FAULT_ID_HD_INVALID_WET_SELF_TEST_STATE, // 105 SW_FAULT_ID_HD_INVALID_PRE_TREATMENT_RECIRC_STATE, - SW_FAULT_ID_HD_INVALID_COMMAND_RESPONSE_ID, // 100 + SW_FAULT_ID_HD_INVALID_COMMAND_RESPONSE_ID, SW_FAULT_ID_HD_INVALID_RESERVOIR_ID, SW_FAULT_ID_HD_INVALID_VALVE_SETTING_ID, - SW_FAULT_ID_HD_SYRINGE_INVALID_BOLUS_CMD, + SW_FAULT_ID_HD_SYRINGE_INVALID_BOLUS_CMD, // 110 SW_FAULT_ID_HD_SYRINGE_INVALID_CONT_CMD, - SW_FAULT_ID_HD_SYRINGE_INVALID_VREF, // 105 + SW_FAULT_ID_HD_SYRINGE_INVALID_VREF, SW_FAULT_ID_HD_SYRINGE_INVALID_STATE, NUM_OF_SW_FAULT_IDS } SW_FAULT_ID_T; @@ -263,10 +271,11 @@ void clearAlarm( ALARM_ID_T alarm ); void clearAlarmCondition( ALARM_ID_T alarm ); void setAlarmUserActionEnabled( ALARM_USER_ACTION_T action, BOOL enabled ); -void signalAlarmSilence( U32 cmd ); +void signalAlarmSilence( ALARM_SILENCE_CMD_T cmd ); void signalAlarmUserActionInitiated( ALARM_USER_ACTION_T action ); BOOL isAlarmActive( ALARM_ID_T alarm ); BOOL isAnyAlarmActive( void ); +BOOL isDialysateRecircBlocked( void ); BOOL doesAlarmStatusIndicateStop( void ); ALARM_PRIORITY_T getCurrentAlarmStatePriority( void ); BOOL isAlarmRecoverable( ALARM_ID_T alarm );