Index: firmware/App/Controllers/SyringePump.c =================================================================== diff -u -ra4d23db9510f983eab3af863d6470263a59ea937 -r269329748ffabc707aa8dd2376fadb92efcca941 --- firmware/App/Controllers/SyringePump.c (.../SyringePump.c) (revision a4d23db9510f983eab3af863d6470263a59ea937) +++ firmware/App/Controllers/SyringePump.c (.../SyringePump.c) (revision 269329748ffabc707aa8dd2376fadb92efcca941) @@ -68,7 +68,6 @@ #define SYRINGE_PUMP_RATE_ALARM_PERSISTENCE 3000 ///< Alarm persistence period (in ms) for syringe pump speed check alarms. #define SYRINGE_PUMP_DIR_ALARM_PERSISTENCE 3000 ///< Alarm persistence period (in ms) for syringe pump direction check alarms. #define SYRINGE_PUMP_OFF_ALARM_PERSISTENCE 1000 ///< Alarm persistence period (in ms) for syringe pump off check alarms. -#define SYRINGE_PUMP_OCCLUSION_ALARM_PERSISTENCE 30 ///< Alarm persistence period (in ms) for syringe pump occlusion alarms. #define SYRINGE_PUMP_ADC_READ_PERSISTENCE 100 ///< Syringe pump ADC stale read alarm persistence time (in ms). #define STEPS_TO_MICROSTEPS( s ) ( (s) * 32.0 ) ///< Macro conversion from steps to microsteps. @@ -314,7 +313,6 @@ initPersistentAlarm( ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR, 0, SYRINGE_PUMP_OFF_ALARM_PERSISTENCE ); initPersistentAlarm( ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR, 0, SYRINGE_PUMP_OFF_ALARM_PERSISTENCE ); initPersistentAlarm( ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR, 0, SYRINGE_PUMP_RATE_ALARM_PERSISTENCE ); - initPersistentAlarm( ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION, 0, SYRINGE_PUMP_OCCLUSION_ALARM_PERSISTENCE ); // Reset request flags resetSyringePumpRequestFlags(); @@ -1539,10 +1537,9 @@ F32 forceDelta = forceAtEndOfPriming - forceAtEndOfSeek; // Occlusion is detected if force at end of prime is > than force at end of seek by 0.5 volts or more BOOL occlusionDetected = ( forceDelta >= SYRINGE_FORCE_OCCLUSION_DIFF_V ? TRUE : FALSE ); - if ( TRUE == isPersistentAlarmTriggered( ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION, occlusionDetected ) ) + if ( TRUE == occlusionDetected ) { SET_ALARM_WITH_2_F32_DATA( ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION, forceAtEndOfSeek, forceAtEndOfPriming ) // reuse this alarm after prime - forceAtEndOfSeek = 0.0; // reset this value in case we want to prime again result = TRUE; } Index: firmware/App/Modes/SelfTests.c =================================================================== diff -u -raa4db7d76566ad7473f896e543f71fdbbc921ea9 -r269329748ffabc707aa8dd2376fadb92efcca941 --- firmware/App/Modes/SelfTests.c (.../SelfTests.c) (revision aa4db7d76566ad7473f896e543f71fdbbc921ea9) +++ firmware/App/Modes/SelfTests.c (.../SelfTests.c) (revision 269329748ffabc707aa8dd2376fadb92efcca941) @@ -41,7 +41,7 @@ #define PUMP_RUN_SELF_TEST_TIME_MS ( 15 * MS_PER_SECOND ) ///< Self-test time to run pumps in ms. #define PUMP_SELF_TEST_FLOW_RATE_ML_MIN 100 ///< Self-test pump flow rate in mL/min. -#define SYRINGE_PUMP_OCCLUSION_CHECK_DELAY ( 3 * MS_PER_SECOND ) ///< Delay 3 seconds then check for syringe pump prime occlusion. +#define SYRINGE_PUMP_OCCLUSION_CHECK_DELAY ( 1 * MS_PER_SECOND ) ///< Delay 3 seconds then check for syringe pump prime occlusion. #define BLOOD_PUMP_RUN_TIME_PRESSURE_SELF_TEST ( 5 * MS_PER_SECOND ) ///< Pressure self-test time to run blood pump in ms. #define NORMALIZED_PRESSURE_SELF_TEST_TIME ( 4 * MS_PER_SECOND ) ///< Time to wait for pressure to normalize in ms.