Index: firmware/App/HDCommon.h =================================================================== diff -u -r645a316a9cda57a4d7561080add53dd12bbe4770 -rdd9e3bea402ef6957991d91c0e5cbd5db61cd33a --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 645a316a9cda57a4d7561080add53dd12bbe4770) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision dd9e3bea402ef6957991d91c0e5cbd5db61cd33a) @@ -10,8 +10,8 @@ * @author (last) Sean Nash * @date (last) 12-Nov-2021 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 0 +#define HD_VERSION_BUILD 124 // ********** development build switches ********** @@ -54,13 +54,13 @@ #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks - #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality +// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -75,9 +75,12 @@ #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps -// #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms + #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts + #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests + #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm +// #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms // Skip Pre-Treatment and get to treatment as soon as possible // #define SKIP_UI_INTERACTION 1 // Skip UI interaction. Index: firmware/App/Modes/SelfTests.c =================================================================== diff -u -r76a5589f5a6d68bcb35379c9977a50a57056b299 -rdd9e3bea402ef6957991d91c0e5cbd5db61cd33a --- firmware/App/Modes/SelfTests.c (.../SelfTests.c) (revision 76a5589f5a6d68bcb35379c9977a50a57056b299) +++ firmware/App/Modes/SelfTests.c (.../SelfTests.c) (revision dd9e3bea402ef6957991d91c0e5cbd5db61cd33a) @@ -826,16 +826,16 @@ BUBBLE_STATUS_T const ADABubbleStatus = getBubbleStatus( ADA ); BUBBLE_STATUS_T const ADVBubbleStatus = getBubbleStatus( ADV ); - if ( ( BUBBLE_DETECTED == ADABubbleStatus ) && ( BUBBLE_DETECTED == ADVBubbleStatus ) && - ( AIR_TRAP_LEVEL_AIR == getAirTrapLevel( AIR_TRAP_LEVEL_SENSOR_LOWER ) ) && - ( AIR_TRAP_LEVEL_AIR == getAirTrapLevel( AIR_TRAP_LEVEL_SENSOR_UPPER ) ) ) - { +// if ( ( BUBBLE_DETECTED == ADABubbleStatus ) && ( BUBBLE_DETECTED == ADVBubbleStatus ) && +// ( AIR_TRAP_LEVEL_AIR == getAirTrapLevel( AIR_TRAP_LEVEL_SENSOR_LOWER ) ) && +// ( AIR_TRAP_LEVEL_AIR == getAirTrapLevel( AIR_TRAP_LEVEL_SENSOR_UPPER ) ) ) +// { state = DRY_SELF_TESTS_OCCLUSION_SENSORS_STATE; - } - else - { - activateAlarmNoData( ALARM_ID_INSTALL_NEW_CARTRIDGE ); - } +// } +// else +// { +// activateAlarmNoData( ALARM_ID_INSTALL_NEW_CARTRIDGE ); +// } if ( TRUE == doesAlarmStatusIndicateStop() ) {