Index: shared/scripts/configuration/config.py =================================================================== diff -u -r1b46227816628d8648501e93e0d392489f0829c3 -r32d23d68ca62013eeec4abdc7e09b2c9e3731f48 --- shared/scripts/configuration/config.py (.../config.py) (revision 1b46227816628d8648501e93e0d392489f0829c3) +++ shared/scripts/configuration/config.py (.../config.py) (revision 32d23d68ca62013eeec4abdc7e09b2c9e3731f48) @@ -8,7 +8,7 @@ # # @file utils.py # -# @author (last) Joseph varghese +# @author (last) LTTS # @date (last) 18-Jan-2022 # ############################################################################ @@ -32,8 +32,97 @@ BLOOD_PRIMING_TEXT = "Blood Priming" SALINE_UNIT = "mL" BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" +SALINE_BOLUS_CUMULATIVE = 300 +# dictionary of rejection reason from application source code. +# message location -> denali-> Headers-> common-> MsgDefs.h +REJECTION_REASON = { + 0 : "REQUEST_REJECT_REASON_NONE" , # Used when there is no rejection + 1 : "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE" , # "REQuest is not allowed in the current operating mode + 2 : "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM" , # Validated "REQuest was not confirmed by user in reasonable time + 3 : "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE" , # "REQuest is not allowed if not in treatment mode + 4 : "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE" , # "REQuest is not allowed in current treatment state + 5 : "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED" , # "REQuest is not allowed so near end of treatment + 6 : "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE" , # Treatment duration is out of range + 7 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT" , # Treatment time change is less than currently elapsed treatment time + 8 : "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE" , # Blood flow is out of range + 9 : "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE" , # Dialysate flow is out of range + 10 : "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE" , # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit + 11 : "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE" , # Ultrafiltration volume is out of range + 12 : "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE" , # Ultrafiltration rate is out of range + 13 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM" , # Treatment time change is less than minimum treatment time + 14 : "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS" , # Ultrafiltration is not currently in progress + 15 : "REQUEST_REJECT_REASON_UF_NOT_PAUSED" , # Ultrafiltration is not currently paused + 16 : "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS" , # A saline bolus is in progress + 17 : "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE" , # A treatment parameter is out of range + 18 : "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION" , # The Heparin pre-stop setting is greater than the treatment duration + 19 : "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH" , # Arterial pressure low and high alarm limits are not inconsistent + 20 : "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH" , # Venous pressure low and high alarm limits are inconsistent + 21 : "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED" , # Saline bolus volume maximum has been reached - no more saline allowed + 22 : "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS" , # A saline bolus is not in progress + 23 : "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE" , # "REQuested user action is disabled in current state + 24 : "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE" , # "REQuested user action not allowed while alarm is active + 25 : "REQUEST_REJECT_REASON_INVALID_COMMAND" , # "REQuested user action invalid + 26 : "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED" , # The treatment has been completed + 27 : "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED" , # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed + 28 : "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET" , # Ultrafiltration volume is not set yet + 29 : "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM" , # The user has not confirmed patient connection + 30 : "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE" , # Heparin cannot be paused if not currently deliverying Heparin + 31 : "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED" , # Heparin cannot be resumed if not paused + 32 : "REQUEST_REJECT_REASON_DG_COMM_LOST" , # Treatment cannot initiate if DG comm is lost + 33 : "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE" , # Post-treatment reservoirs drain not complete + 34 : "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE" , # Treatment cannot initiate if DG is not in standby idle state + 35 : "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT" , # "REQuest message not formatted properly + 36 : "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME" , # Given date/time is invalid + 37 : "REQUEST_REJECT_REASON_NO_NEW_TREATMENT_ALARM_TRIGGERED" , # Treatment cannot initiate if an alarm with no new treatment property has triggered before + 38 : "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED" , # Battery does not have enough charge to start treatment + 39 : "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED" , # Cannot move on to recirculate without completing full rinseback +} +NUM_OF_REQUEST_REJECT_REASONS = 39 + +#main treatment pressure +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" +ACCEPTED = True +REJECTED = False + +#pressure +PRESSURE_STEPS = 10 +ARTERIAL_PRESSURE_MINIMUM = -400 +ARTERIAL_PRESSURE_MAXIMUM = +600 +ARTERIAL_PRESSURE_LOW_MIN = -300 +ARTERIAL_PRESSURE_LOW_DEF = -300 +ARTERIAL_PRESSURE_LOW_MAX = +200 +ARTERIAL_PRESSURE_HIGH_MIN = -300 +ARTERIAL_PRESSURE_HIGH_DEF = +100 +ARTERIAL_PRESSURE_HIGH_MAX = +200 + +VENOUS_PRESSURE_MINIMUM = -100 +VENOUS_PRESSURE_MAXIMUM = +700 +VENOUS_PRESSURE_LOW_MIN = -100 +VENOUS_PRESSURE_LOW_DEF = -100 +VENOUS_PRESSURE_LOW_MAX = +600 +VENOUS_PRESSURE_HIGH_MIN = +100 +VENOUS_PRESSURE_HIGH_DEF = +400 +VENOUS_PRESSURE_HIGH_MAX = +600 + +#main_treatment_flows +BLOOD_FLOW_MINIMUM_VALUE = 100 +BLOOD_FLOW_BUFFER = 25 +FLOW_SLIDER_WIDTH_BUFFER = 37 +BLOOD_FLOW_MAXIMUM_VALUE = 500 +DIALYSATE_FLOW_MINIMUM_VALUE = 0 +DIALYSATE_FLOW_MAXIMUM_VALUE = 0 # Seems to be bug. need change +FLOW_UNIT = "mL/min" +BLOOD_FLOW_TEXT = "blood" +DIALYSATE_FLOW_TEXT = "dialysate" + #main treatment screen VITALS_TITLE = "VITALS" OUT_OF_RANGE_COLOR = "#c53b33"