# -S, --disable-sd-card-fail-log-stop disable-sd-card-fail-log-stop # -k, --enable-check-in-log Enables Check-In Log # -K, --enable-acknow-log Enables Acknowledgment Log AUT_NAME = "leahi -k -K -S -q" AUT_NAME_ONLY = "leahi" # Need only the AUT name for tst_ui_logs, do not add options # Configuration application_init.py TMP_DIR = "/tmp/" APP_POST_LOG_LOCATION = "".join([str(TMP_DIR),'/post.log']) #Service Export Logs ENABLED = True DEVICE_SETTINGS_SCREEN_TITLE_TEXT = "Device Settings" EXPORT_LOG_TEXT = "Export Logs" EXPORT_LOGS_OPTIONS = ["Application", "Service", "Treatment"] EXPORT_LOG_STATUS = "Application log export to USB is complete" EXPORT_LOG_PROGRESS_STATUS = "Service log export to USB in progress ... " SERVICE_SCREEN_TITLE_TEXT = "Service" # Headerbar_information_popup INFORMATION_PARAMETERS = [ "OS Version", "UI Version", "TD Version", "TD FPGA Version", "TD Serial Number", "DD Version", "DD FPGA Version", "DD Serial Number", ] #Device Settings Information Version INFORMATION_SCREEN_TITLE_TEXT = "Information" INFORMATION_TITLES = ["Information", "Versions"] VERSION_PARAMETERS = [ "Information", "UI Version", "TD Version", "TD FPGA Version", "TD Serial Number", "DD Version", "DD FPGA Version", "DD Serial Number" ] SERVICES_PARAMETERS = [ "TD Last Service Date", "TD Next Service Date", "DD Last Service Date", "DD Next Service Date" ] SERIVCES_TITLE = "Service" WATER_PARAMETERS = ["Water Configuration", "Water Input"] # General Alarm Requirements Instruction NUM_OF_ALARM_PRIORITIES = 4 # Total number of alarm priorities ALARM_MUTE_FLAG = 0B0000001000000000 ALARM_UNMUTE_FLAG = 0B0000000000000000 ALARM_PRIORITY_OPTIONS = { 0 : 'ALARM_PRIORITY_NONE' , 1 : 'ALARM_PRIORITY_LOW' , 2 : 'ALARM_PRIORITY_MEDIUM', 3 : 'ALARM_PRIORITY_HIGH', } #HeaderBar WiFi WIFI_POPUP_TEXT = "WiFi Connection Error" # Device Settings WiFi WIFI_TEXT = "Wi-Fi" WIFI_PARAMETERS_TEXTS = ["SSID", "IP Address", "Gateway", "Subnet Mask", "DNS"] WIFI_SCREEN_SCAN_BUTTON_TEXT = "SCAN" DISABLED = False ALARMS_COLORS_HEADER = { "ALARM_PRIORITY_NONE" : "#438feb", "ALARM_PRIORITY_LOW" : "#db8f00", "ALARM_PRIORITY_MEDIUM" : "#db8f00", "ALARM_PRIORITY_HIGH" : "#c53b33" } ALARM_REJECT_NOTIFICATION_TEMPLATE = "No Active Alarm List [{}]" #Create Rx ACID_CONCENTRATE = ["1.0 K, 2.50 Ca, 1 Mg","2.0 K, 2.50 Ca, 1 Mg","3.0 K, 2.50 Ca, 1 Mg"] DIALYZER_TYPE = ["Diacap Pro 13H","Diacap Pro 16H", "Diacap Pro 19H", "Optiflux F160NRe", "Optiflux F180NRe", "Optiflux F200NRe","Optiflux F250NRe"] VITALS = ["OFF","5","10","15","20","30","60"] BICARBONATE = ["Sodium Bicarbonate"] #Heparin heparin_off = { "Heparin Type" :"OFF", "Dispensing Rate" :"OFF", "Bolus Volume" :"OFF", "Stop Time" :"OFF"} heparin_values = { "Heparin Type" :"Unfractionated 1,000", "Dispensing Rate" :"0.5", "Bolus Volume" :"0.4", "Stop Time" :"60"} PAUSE = 'Pause' ACTIVE = 'Active' RESUME = 'Resume' COMPLETE = 'Complete' HEPARIN = 'Heparin' CREATERX = 'Rx' VALIDATE = 'VALIDATE' CONFIRM = 'CONFIRM' NEXT = 'Next' AUTO_LOAD = 'Auto Load' WATER_SAMPLE = 'Water Sample' START = 'Start' AUTO_EJECT = 'Auto Eject' # Settings Service DEFAULT_SERVICE_PASSWORD_RAW = "Atal.Matal.22leh" # TODO need to update if we ever change the default NEW_PASSWORD_RAW = "Test4.Ksah.sk43sa" MANUFACTURING_SCREEN_TITLE_TEXT = "Manufacturing Setup" SERVICE_SCREEN_TITLE_TEXT = "Service" ADVANCED_MODES_SCREEN_TITLE_TEXT = "Advanced Mode" DATE_AND_TIME_SCREEN_TITLE_TEXT = "Date and Time" DATE_AND_TIME_PARAMETERS_TEXTS = ["NTP", "(Network Time Protocol)", "Time", "(HH:mm:ss)", "Date", "(MM/dd/yyyy)"] ENABLE_ROOT_SSH_SCREEN_TITLE_TEXT = "Enable Root SSH" ENABLE_ROOT_SSH_PARAMETERS_TEXTS = ["Enable SSH Login", "Enable Root Login"] FACTORY_RESET_SCREEN_TITLE_TEXT = "Factory Reset" FACTORY_RESET_SCREEN_TEXT = "Do you want to perform the factory reset?" #Blood Set Auto Load BLOOD_SET_AUTO_LOAD_REJECTION = "[1] Request is not allowed in the current operating mode" BLOOD_SET_AUTO_EJECT_REJECTION = "[1] Request is not allowed in the current operating mode" #Device Settings Options DEVICE_SETTINGS = "Device Settings" ADVANCED_MODE = "Advanced Mode" DEVICE_INFORMATION = "Device Information" WI_FI = "Wi-Fi" DEVICE_CLEANING = "Device Cleaning" SERVICE = "Service" EXPORT_LOGS = "Export Logs" VOLUME_AND_BRIGHTNESS = "Volume And Brightness" FEATURE_CONFIGURATIONS = "Feature Configurations" ADVANCED_INSTITUTIONAL_SETTINGS = "Advanced Institutional Settings" FACTORY_RESET = "Factory Reset" ENABLE_ROOT_SSH = "Enable Root SSH" INSTITUTIONAL_CONFIGURATIONS = "Institutional Configurations" DATE_AND_TIME = "Date and Time" LANGUAGE = "Language" #Menu Bar PRESCRIPTIONS = "Prescriptions" TREATMENT = "Treatment" SETTINGS = "Settings" # Pre-Treatment Foundation CONCENTRATES_PAGE_TITLE = "Connect Acid and Bicarbonate Concentrates" CONCENTRATES_PAGE_CONTENTS = [ "Remove acid connector and connect to acid concentrate.", "Connect dry bicarbonate.", ] INSTALLATION_STEPPER_1_PAGE_TITLE = "Install Blood Tubing Set" INSTALL_BLOOD_TUBING_SET_CONTENTS = [ "Open the blood pump door.", "Insert blood tubing set and ensure it is secure.", "Push the blood tube into the blood pump.", "Close the blood pump door.", ] INSTALLATION_STEPPER_2_PAGE_TITLE = "Install Bloodlines" INSTALL_BLOODLINES_CONTENTS = [ "Insert saline line into the first slot.", "Insert arterial line into the second slot.", "Ensure the venous line is placed in the bubble detector.", "Insert the venous line into the third slot.", "Connect the arterial and venous bloodlines using the recirculation connector.", ] INSTALLATION_STEPPER_3_PAGE_TITLE = "Install Pressure Lines and Dialyzer" INSTALL_PRESSURE_LINES_CONTENTS = [ "Connect the arterial pressure line to the arterial pressure transducer port.", "Connect the venous pressure line to the venous pressure transducer port.", "Insert dialyzer into the holder and connect the dialysate lines.", "Connect the bloodlines to the dialyzer.", "Clamp the venous chamber line.", "Clamp the heparin line.", ] SELF_TESTS_PAGE_CONTENTS = [ "Auto-Load Blood Tubing", "Cartridge Install Checks", "Pressure Leak Check", ] SALINE_PAGE_TITLE = "Connect Saline Bag" SALINE_PAGE_CONTENTS = [ "Hang saline bag on the hook.", "Clamp saline line.", "Use the saline line to spike saline bag.", "Unclamp saline line.", ] PRIME_PAGE_CONTENTS = ["Blood Tubing Circuit Priming", "Dialysate Circuit Priming"] CONNECT_PAGE_TITLE = "Connect Bloodlines to the Patient" CONNECT_PAGE_CONTENTS = [ "Clamp arterial and venous bloodlines (2 clamps).", "Remove recirculation connector from the bloodlines.", "Connect bloodlines to patient access lines.", "Unclamp arterial and venous bloodlines (2 clamps).", ] DISCONNECT_PAGE_TITLE = "Remove Concentrates and Blood Tubing Set" DISCONNECT_PAGE_CONTENTS = [ "Remove blood tubing set and dialyzer.", "Remove acid and bicarbonate concentrates.", ] INSTALLATION_PAGE_TITLE = "Install Concentrates and Blood Tubing Set" INSTALLATION_PAGE_CONTENTS = [ "Install acid and bicarbonate concentrates.", "Install blood tubing set and dialyzer.", ] START_TREATMENT_REJECTION_NOTIFICATION = "[1] Request is not allowed in the current operating mode"