/*! * * Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. * \copyright * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour * \date (last) 27-May-2021 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * */ #include "MAlarmStatusData.h" using namespace Model; using namespace Gui; /*! * \brief MAlarmStatus::toText * \details Looks up the alarm description using the alarm enum * \param vAlarmID - Alarm Id * \return The alarm description */ QString MAlarmStatus::toText(GuiAlarmID vAlarmID) { QString result; if ( vAlarmID == 0 ) return result; switch (vAlarmID) { case GuiAlarmID::ALARM_ID_NO_ALARM : { result = QObject::tr("Indication for when no alarms is a possible situation." ); break; } case GuiAlarmID::ALARM_ID_STUCK_BUTTON_TEST_FAILED : { result = QObject::tr("Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up." ); break; } case GuiAlarmID::ALARM_ID_HD_FPGA_POST_TEST_FAILED : { result = QObject::tr("HD FPGA POST failure." ); break; } case GuiAlarmID::ALARM_ID_DG_FPGA_POST_TEST_FAILED : { result = QObject::tr("DG FPGA POST failure." ); break; } case GuiAlarmID::ALARM_ID_WATCHDOG_POST_TEST_FAILED : { result = QObject::tr("Watchdog POST failure." ); break; } case GuiAlarmID::ALARM_ID_UI_COMM_POST_FAILED : { result = QObject::tr("UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." ); break; } case GuiAlarmID::ALARM_ID_RTC_CONFIG_ERROR : { result = QObject::tr("Real-time clock configuration error." ); break; } case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("HD accelerometer failed POST." ); break; } case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("DG accelerometer failed POST." ); break; } case GuiAlarmID::ALARM_ID_RTC_OR_TIMER_ACCURACY_FAILURE : { result = QObject::tr("RTC or MCU timer inaccurate." ); break; } case GuiAlarmID::ALARM_ID_DG_HEATERS_SELF_TEST_FAILURE : { result = QObject::tr("DG heaters failed POST." ); break; } case GuiAlarmID::ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("HD firmware image integrity POST test failed." ); break; } case GuiAlarmID::ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("DG firmware image integrity POST test failed." ); break; } case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD blood flow invalid calibration." ); break; } case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD dialysate flow invalid calibration." ); break; } case GuiAlarmID::ALARM_ID_HD_SOFTWARE_FAULT : { result = QObject::tr("HD Software fault.\nSoftware found itself in an unexpected state." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_OFF_CHECK : { result = QObject::tr("Blood pump failed motor off check.\nMeasured speed while commanded off." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Blood pump failed motor direction check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor direction check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } case GuiAlarmID::ALARM_ID_WATCHDOG_EXPIRED : { result = QObject::tr("Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time." ); break; } case GuiAlarmID::ALARM_ID_UI_COMM_TIMEOUT : { result = QObject::tr("User interface communication timeout." ); break; } case GuiAlarmID::ALARM_ID_COMM_TOO_MANY_BAD_CRCS : { result = QObject::tr("Too many bad CRCs detected on received system messages." ); break; } case GuiAlarmID::ALARM_ID_CAN_MESSAGE_NOT_ACKED : { result = QObject::tr("System message that required acknowledgment was not acknowledged." ); break; } case GuiAlarmID::ALARM_ID_UF_RATE_TOO_HIGH_ERROR : { result = QObject::tr("Ultrafiltration rate is too high error during treatment." ); break; } case GuiAlarmID::ALARM_ID_UF_VOLUME_ACCURACY_ERROR : { result = QObject::tr("Ultrafiltration volume accuracy error during treatment." ); break; } case GuiAlarmID::ALARM_ID_HD_FPGA_COMM_TIMEOUT : { result = QObject::tr("HD FPGA communication down for too long." ); break; } case GuiAlarmID::ALARM_ID_VALVE_CONTROL_FAILURE : { result = QObject::tr("FPGA not accepting commanded valve states." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed motor speed check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed motor speed check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate outlet pump failed motor speed check.\nMeasured vs commanded." ); break; } case GuiAlarmID::ALARM_ID_HD_CRITICAL_DATA_ERROR : { result = QObject::tr("HD critical data integrity check failed." ); break; } case GuiAlarmID::ALARM_ID_DG_CRITICAL_DATA_ERROR : { result = QObject::tr("DG critical data integrity check failed." ); break; } case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_FAILURE : { result = QObject::tr("HD accelerometer error (no readings or FPGA reports error)." ); break; } case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_FAILURE : { result = QObject::tr("DG accelerometer error (no readings or FPGA reports error)." ); break; } case GuiAlarmID::ALARM_ID_HD_VALVE_HOMING_FAILED : { result = QObject::tr("HD valve homing failed." ); break; } case GuiAlarmID::ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT : { result = QObject::tr("HD valve transition time out." ); break; } case GuiAlarmID::ALARM_ID_HD_VALVE_NOT_FUNCTIONAL : { result = QObject::tr("HD valve not functional." ); break; } case GuiAlarmID::ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE : { result = QObject::tr("HD valve current out of range." ); break; } case GuiAlarmID::ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE : { result = QObject::tr("HD valve position out of target." ); break; } case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading arterial pressure sensor." ); break; } case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading venous pressure sensor." ); break; } case GuiAlarmID::ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT : { result = QObject::tr("HD requests DG command with invalid parameter fault." ); break; } case GuiAlarmID::ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management overall group record CRC invalid." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD blood pump occlusion self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate inlet pump occlusion self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate outlet pump occlusion self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial pressure self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous pressure self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD blood flow meter status check self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate flow meter status check self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE : { result = QObject::tr("HD blood leak detector self-test failure alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("HD monitored voltage is out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG monitored voltage is out of range." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from encoder) error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from controller) error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_FAULT : { result = QObject::tr("HD syringe pump fault reported by FPGA." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR : { result = QObject::tr("HD syringe pump over travel error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR : { result = QObject::tr("HD syringe pump DAC write failure." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR : { result = QObject::tr("HD syringe pump is running while the BP is off." ); break; } case GuiAlarmID::ALARM_ID_DG_FPGA_COMM_TIMEOUT : { result = QObject::tr("DG FPGA communication down for too long." ); break; } case GuiAlarmID::ALARM_ID_DG_LOAD_CELL_ADC_ERROR : { result = QObject::tr("DG load cell ADC error." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR : { result = QObject::tr("HD venous pressure sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE : { result = QObject::tr("HD venous pressure sensor temperature out of range error." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD BP occlusion sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPi occlusion sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPo occlusion sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD BP occlusion sensor error." ); break; } case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPi occlusion sensor error." ); break; } case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPo occlusion sensor error." ); break; } case GuiAlarmID::ALARM_ID_DG_CONCENTRATE_PUMP_FAULT : { result = QObject::tr("DG concentrate pump fault." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD blood flow sensor error." ); break; } case GuiAlarmID::ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read." ); break; } case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD dialysate flow sensor error." ); break; } case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read - slow packet." ); break; } case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read - slow packet." ); break; } case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE : { result = QObject::tr("DG load cells weight out of range before tare." ); break; } case GuiAlarmID::ALARM_ID_HD_BATTERY_COMM_FAULT : { result = QObject::tr("HD battery communication fault." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_STALL : { result = QObject::tr("HD syringe pump stall alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT : { result = QObject::tr("HD no cartridge self-test timeout." ); break; } case GuiAlarmID::ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT : { result = QObject::tr("HD dry self-test timeout." ); break; } case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT : { result = QObject::tr("DG temperature sensor error flag fault." ); break; } case GuiAlarmID::ALARM_ID_DG_SOFTWARE_FAULT : { result = QObject::tr("DG software fault.\nSoftware found itself in an unexpected state." ); break; } case GuiAlarmID::ALARM_ID_RTC_COMM_ERROR : { result = QObject::tr("Real-time clock communication error." ); break; } case GuiAlarmID::ALARM_ID_DG_INVALID_LOAD_CELL_VALUE : { result = QObject::tr("DG invalid load cell value." ); break; } case GuiAlarmID::ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT : { result = QObject::tr("DG drain circulation line timeout." ); break; } case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT : { result = QObject::tr("DG temperature sensors ADC fault." ); break; } case GuiAlarmID::ALARM_ID_DG_FLOW_METER_CHECK_FAILURE : { result = QObject::tr("DG flow meter check failure alarm." ); break; } case GuiAlarmID::ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE : { result = QObject::tr("RO pump flow rate out of range." ); break; } case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE : { result = QObject::tr("DG flow rate out of upper range." ); break; } case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE : { result = QObject::tr("DG flow rate out of lower range." ); break; } case GuiAlarmID::ALARM_ID_RO_PUMP_OFF_FAULT : { result = QObject::tr("DG RO pump off fault." ); break; } case GuiAlarmID::ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE : { result = QObject::tr("DG RO pump pressure out of range." ); break; } case GuiAlarmID::ALARM_ID_DRAIN_PUMP_RPM_OUT_OF_RANGE : { result = QObject::tr("DG drain pump RPM out of range." ); break; } case GuiAlarmID::ALARM_ID_DRAIN_PUMP_OFF_FAULT : { result = QObject::tr("DG drain pump off fault." ); break; } case GuiAlarmID::ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE : { result = QObject::tr("DG heaters cold junction temperature out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_HEATERS_FAULT : { result = QObject::tr("DG heaters fault." ); break; } case GuiAlarmID::ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE : { result = QObject::tr("DG thermistors/sensors temperature out of range." ); break; } case GuiAlarmID::ALARM_ID_CP1_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP1 speed control error." ); break; } case GuiAlarmID::ALARM_ID_CP2_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP2 speed control error." ); break; } case GuiAlarmID::ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE : { result = QObject::tr("RO rejection ratio out of range." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_PRESSURE_FAULT : { result = QObject::tr("Inlet water pressure fault." ); break; } case GuiAlarmID::ALARM_ID_PRESSURE_SENSOR_FAULT : { result = QObject::tr("Pressure sensor fault." ); break; } case GuiAlarmID::ALARM_ID_CONDUCTIVITY_SENSOR_FAULT : { result = QObject::tr("Conductivity sensor fault." ); break; } case GuiAlarmID::ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR : { result = QObject::tr("Manufacturing record CRC failure." ); break; } case GuiAlarmID::ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("Air trap level sensors reporting illegal combination of air/fluid." ); break; } case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management individual record CRC invalid." ); break; } case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID : { result = QObject::tr("DG/HD NV data management individual record time invalid." ); break; } case GuiAlarmID::ALARM_ID_DG_RESTARTED_FAULT : { result = QObject::tr("HD reports DG restarted fault." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR : { result = QObject::tr("HD syringe pump ADC error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR : { result = QObject::tr("HD syringe pump speed check error." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR : { result = QObject::tr("HD syringe pump not stopped in off state error." ); break; } case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_FAULT : { result = QObject::tr("HD blood leak detector fault." ); break; } case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION : { result = QObject::tr("DG load cells invalid calibration." ); break; } case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATERS_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heaters internal temperature out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater internal temperature out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT : { result = QObject::tr("DG heaters on with no flow time out." ); break; } case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial air bubble detector self-test failure." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_HIGH : { result = QObject::tr("HD end of treatment alarm (high priority - user still not acting to end treatment)." ); break; } case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK : { result = QObject::tr("Blood sitting too long after treatment stopped by user alarm (>10 min)." ); break; } case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_DETECTED : { result = QObject::tr("HD blood leak detected alarm." ); break; } case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_LOW : { result = QObject::tr("Venous pressure too low during treatment." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED : { result = QObject::tr("HD venous air bubble detected alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD venous air bubble detected rinseback alarm." ); break; } case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_HIGH : { result = QObject::tr("Venous pressure too high during treatment." ); break; } case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_LOW : { result = QObject::tr("Arterial pressure too low during treatment." ); break; } case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_HIGH : { result = QObject::tr("Arterial pressure too high during treatment." ); break; } case GuiAlarmID::ALARM_ID_DG_FLUID_LEAK_DETECTED : { result = QObject::tr("DG fluid leak detected alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_FLUID_LEAK_DETECTED : { result = QObject::tr("HD fluid leak detected alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_SHOCK : { result = QObject::tr("HD experienced large acceleration." ); break; } case GuiAlarmID::ALARM_ID_DG_SHOCK : { result = QObject::tr("DG experienced large acceleration." ); break; } case GuiAlarmID::ALARM_ID_HD_EXCESSIVE_TILT : { result = QObject::tr("HD tilt exceeds maximum." ); break; } case GuiAlarmID::ALARM_ID_DG_EXCESSIVE_TILT : { result = QObject::tr("DG tilt exceeds maximum." ); break; } case GuiAlarmID::ALARM_ID_HD_AC_POWER_LOST : { result = QObject::tr("HD AC power lost alarm." ); break; } case GuiAlarmID::ALARM_ID_DG_COMM_TIMEOUT : { result = QObject::tr("Dialysate generator communication timeout." ); break; } case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_IN_PUMP : { result = QObject::tr("Dialysate inlet pump occlusion detected." ); break; } case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_OUT_PUMP : { result = QObject::tr("Dialysate outlet pump occlusion detected." ); break; } case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT : { result = QObject::tr("DG dialysate generation conductivity fault alarm." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_TEMPERATURE : { result = QObject::tr("Inlet water temperature too high." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_TEMPERATURE : { result = QObject::tr("Inlet water temperature too low." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too high." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too low." ); break; } case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_PRESSURE : { result = QObject::tr("Inlet water pressure too low." ); break; } case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_HIGH : { result = QObject::tr("HD prime completed high priority alarm." ); break; } case GuiAlarmID::ALARM_ID_UV_REACTOR_NOT_HEALTHY : { result = QObject::tr("Inlet or Outlet UV reactor not healthy." ); break; } case GuiAlarmID::ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE : { result = QObject::tr("DG fan RPM out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME : { result = QObject::tr("DG dialysate fill runs out of time." ); break; } case GuiAlarmID::ALARM_ID_NVDATA_EEPROM_OPS_FAILURE : { result = QObject::tr("EEPROM operations (read, write, erase) failure." ); break; } case GuiAlarmID::ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR : { result = QObject::tr("Service record CRC failure." ); break; } case GuiAlarmID::ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR : { result = QObject::tr("HW usage data (treatment time in HD and total consumed water in DG) failure." ); break; } case GuiAlarmID::ALARM_ID_HD_COMM_TIMEOUT : { result = QObject::tr("HD communication timeout." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH : { result = QObject::tr("Blood pump rotor speed too high." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Blood flow sensor signal strength too low." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Dialysate flow sensor signal strength too low." ); break; } case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } case GuiAlarmID::ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment rinseback operation timeout." ); break; } case GuiAlarmID::ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment re-circ sub-mode for too long." ); break; } case GuiAlarmID::ALARM_ID_CARTRIDGE_DOOR_OPENED : { result = QObject::tr("HD cartridge door opened alarm." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY : { result = QObject::tr("HD syringe empty alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION : { result = QObject::tr("HD syringe pump occlusion alarm." ); break; } case GuiAlarmID::ALARM_ID_DG_BAD_INLET_WATER_QUALITY : { result = QObject::tr("Inlet water quality is bad (temperature, conductivity, pressure)." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM : { result = QObject::tr("HD syringe pump not enough Heparin alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED : { result = QObject::tr("HD arterial air bubble detected alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD arterial air bubble detected rinseback alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR : { result = QObject::tr("HD pump direction status error." ); break; } case GuiAlarmID::ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR : { result = QObject::tr("Calibration record CRC failure." ); break; } case GuiAlarmID::ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH : { result = QObject::tr("HD active reservoir is full during treatment and DG not ready to switch reservoirs." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_SITTING_WARNING : { result = QObject::tr("Blood sitting too long warning (>4 min)." ); break; } case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_ALARM : { result = QObject::tr("HD end of treatment alarm (user not acting to end treatment)." ); break; } case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_MEDIUM : { result = QObject::tr("HD prime completed medium priority alarm." ); break; } case GuiAlarmID::ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD Saline bolus volume check failure." ); break; } case GuiAlarmID::ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD rinseback volume check failure." ); break; } case GuiAlarmID::ALARM_ID_END_TREATMENT_TIMEOUT_ALARM : { result = QObject::tr("HD end treatment sub-mode timeout alarm." ); break; } case GuiAlarmID::ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD blood prime volume check failure." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_DETECTED : { result = QObject::tr("HD syringe detected alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED : { result = QObject::tr("HD syringe pump syringe removed alarm." ); break; } case GuiAlarmID::ALARM_ID_EMPTY_SALINE_BAG : { result = QObject::tr("HD Saline bag is empty." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_BY_USER : { result = QObject::tr("Treatment stopped by user action - pressed stop button." ); break; } case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_WARNING : { result = QObject::tr("HD end of treatment warning." ); break; } case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY : { result = QObject::tr("HD prime completed low priority alarm." ); break; } case GuiAlarmID::ALARM_ID_PRIME_OUT_OF_TIME : { result = QObject::tr("HD prime out of time alarm." ); break; } case GuiAlarmID::ALARM_ID_HD_PRIME_PURGE_AIR_TIME_OUT : { result = QObject::tr("HD time out on prime sub-mode purge air state." ); break; } case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT : { result = QObject::tr("HD prime dialysate dialyzer time out alarm." ); break; } case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT : { result = QObject::tr("HD prime dialysate bypass time out alarm." ); break; } case GuiAlarmID::ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode dry self-tests failure." ); break; } case GuiAlarmID::ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode wet self-tests failure." ); break; } case GuiAlarmID::ALARM_ID_RTC_BATTERY_LOW : { result = QObject::tr("RTC battery low." ); break; } case GuiAlarmID::ALARM_ID_RTC_RAM_OPS_ERROR : { result = QObject::tr("RTC (i.e read time) or RAM operations failure (read or write)." ); break; } case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK : { result = QObject::tr("HD in treatment stopped sub-mode after rinseback completed (no escalation)." ); break; } case GuiAlarmID::ALARM_ID_INSTALL_NEW_CARTRIDGE : { result = QObject::tr("HD needs new cartridge to be installed." ); break; } case GuiAlarmID::ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY : { result = QObject::tr("HD cartridge installed improperly alarm." ); break; } case GuiAlarmID::ALARM_ID_NO_CARTRIDGE_LOADED : { result = QObject::tr("HD no cartridge loaded alarm." ); break; } case GuiAlarmID::ALARM_ID_CARTRIDGE_REMOVAL_FAILURE : { result = QObject::tr("HD fail to remove cartridge alarm." ); break; } case GuiAlarmID::ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Bicarb conductivity out of range during bicarb pump check alarm." ); break; } case GuiAlarmID::ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT : { result = QObject::tr("DG reservoir drain time out." ); break; } case GuiAlarmID::ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT : { result = QObject::tr("DG reservoir fill time out." ); break; } case GuiAlarmID::ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT : { result = QObject::tr("DG reservoir leak time out." ); break; } case GuiAlarmID::ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensors difference out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG heat disinfect target temperature time out (could not reach to temperature)." ); break; } case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG heat disinfect inlet pressure and temperature sensors out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG heat disinfect inlet conductivity and temperature out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG chemical disinfect could not reach to target temperature." ); break; } case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG chemical disinfect inlet pressure and temperature sensors out of range." ); break; } case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG chemical disinfect inlet conductivity and temperature out of range." ); break; } case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Total number of alarms." ); break; } default: result = QObject::tr("ALARM_ID_UNDEFINED [%1]").arg(int(vAlarmID)); break; } return result; }