# ###################################################################################################### # Do not use data message with change interval in here, it affects the instructions update performance. # # ###################################################################################################### # multiple value reserved blocks can be used even in each line. # format is as the following (look at the Messages_List.xlsx for the id and parameters): # {:::} # extra string can be used for unit(mL) which also accepts space # In case extra string or precision is not being used leave it empty eg. {77:1::} # the format shall always have three ':' and message id and parameter number shall not be ignored. # otherwise will NOT be identified as a value reserved block and will be used as part of the string. # Entry format: # [^] # "Title" = # <Instruction step> = <image.png> # - OR - # [<Prefix '$' for HDF mode><Step Tite>] # "Title" = <Title string> # <Instruction step> = <image.png> # ###################################################################################################### [Concentrates] Title = Connect Acid and Bicarbonate Concentrates Remove acid connector and connect to acid concentrate. = Concentrates_1.png Connect dry bicarbonate. = Concentrates_2.png [Installation^Blood Tubing Set] Title = Install Blood Tubing Set Open the blood pump door. = Installation_BloodTube_1.png Insert blood tubing set and ensure it is secure. = Installation_BloodTube_2.png Push the blood tube into the blood pump. = Installation_BloodTube_3.png Close the blood pump door. = Installation_BloodTube_4.png [Installation^Bloodlines] Title = Install Bloodlines Insert saline line into the first slot. = Installation_Bloodlines_1.png Insert arterial line into the second slot. = Installation_Bloodlines_2.png Ensure the venous line is placed in the bubble detector. = Installation_Bloodlines_3.png Insert the venous line into the third slot. = Installation_Bloodlines_4.png Connect the arterial and venous bloodlines using the recirculation connector. Ensure it is tightened. = Installation_Bloodlines_5.png [Installation^Pressure Lines and Dialyzer] Title = Install Pressure Lines and Dialyzer Connect the arterial pressure line to the arterial pressure transducer port. = Installation_CPLD_1.png Connect the venous pressure line to the venous pressure transducer port. = Installation_CPLD_2.png Insert dialyzer into the holder and connect the dialysate lines. = Installation_CPLD_3.png Connect the bloodlines to the dialyzer. = Installation_CPLD_4.png Clamp the venous chamber line. = Installation_CPLD_5.png Clamp the heparin line. = Installation_CPLD_6.png [@Installation] Title = Install Concentrates and Blood Tubing Set Install acid and bicarbonate concentrates. = Install_Advanced_1.png Install blood tubing set and dialyzer. = Install_Advanced_2.png [Saline] Title = Connect Saline Bag Hang saline bag on the hook. = Saline_1.png Clamp saline line. = Saline_2.png Use the saline line to spike saline bag. = Saline_3.png Unclamp saline line. = Saline_4.png [@Saline] Title = Connect Saline Bag Spike and connect saline bag. = Saline_Advanced_1.png [Connect] Title = Connect Bloodlines to the Patient Clamp arterial and venous bloodlines (2 clamps). = Connect_1.png Remove recirculation connector from the bloodlines. = Connect_2.png Connect bloodlines to patient access lines. = Connect_3.png Unclamp arterial and venous bloodlines (2 clamps). = Connect_4.png [@Connect] Title = Connect Bloodlines to the Patient Connect bloodlines to patient access lines. = Connect_Advanced_1.png [Disconnection] Title = Remove Concentrates and Blood Tubing Set Remove blood tubing set and dialyzer. = Install_Advanced_2.png Remove acid and bicarbonate concentrates. = Install_Advanced_1.png [Water Sample] Title = Test Primary Carbon Filter Test the primary carbon filter and select the result below. = Water_Sample_1.png [Blood Return Setup] Title = Blood Return Connection Clamp arterial bloodlines and disconnect. = Return_Blood_1.png Connect arterial bloodline to the saline y-connector. = Return_Blood_2.png Unclamp arterial bloodline and saline y-connector. = Return_Blood_3.png [$Blood Return Setup] Title = Blood Return Connection Clamp arterial bloodlines and disconnect. Connect arterial bloodline to the substitution line using a sterile connector. Unclamp arterial bloodline and substitution line. [Recirculate Set Up] Title = Connect Recirculation Lines Clamp venous bloodline and disconnect. Clamp arterial bloodlines and disconnect from saline y-connector. Connect arterial and venous bloodlines using the recirculation connector. Unclamp arterial and venous bloodlines. [$Recirculate Set Up] Title = Connect Recirculation Lines Clamp venous bloodline and disconnect. Clamp arterial and disconnect from the substitution line. Connect substitution line to the appropriate dilution port. Connect arterial and venous bloodlines using the recirculation connector. Unclamp arterial and venous bloodlines. [Reconnect To Patient] Title = Connect Patient Bloodlines Clamp arterial and venous bloodlines. Remove arterial and venous line recirculation connector. Connect arterial and venous bloodlines to patient access lines. Unclamp arterial and venous bloodlines. [$Reconnect To Patient] Title = Connect Patient Bloodlines Clamp arterial and venous bloodlines. Remove arterial and venous line recirculation connector. Connect arterial and venous bloodlines to patient access lines. Unclamp arterial and venous bloodlines.