ui_interface
0
0
678
1082
&1 States/&2 Pre-Treatment &States
6
6
6
6
-
-
0
0
10
color: rgb(238, 238, 236);
background-color: rgb(252, 175, 62);
Pre-Treatment States
Qt::AlignCenter
-
reset
-
true
0
-479
650
1515
6
6
6
6
-
295
215
16777215
215
8
50
false
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
true
false
2
true
43
350
true
18
21
false
00
1
2
3
4
5
6
7
8
Pre-Treatment States (subMode) [HD_Pre_Treatment_Mode_States]
Description
-
HD_PRE_TREATMENT_START_STATE
-
Start pre-treatment mode state
-
HD_PRE_TREATMENT_WATER_SAMPLE_STATE
-
Water sample state
-
HD_PRE_TREATMENT_SELF_TEST_CONSUMABLE_STATE
-
Consumable self-tests state
-
HD_PRE_TREATMENT_SELF_TEST_NO_CART_STATE
-
Self tests with no cartridge state
-
HD_PRE_TREATMENT_CART_INSTALL_STATE
-
Consumable and cartridge installation state
-
HD_PRE_TREATMENT_SELF_TEST_DRY_STATE
-
Self tests dry state
-
HD_PRE_TREATMENT_PRIME_STATE
-
Prime blood and dialysate circuits and run wet self-tests state
-
HD_PRE_TREATMENT_RECIRCULATE_STATE
-
Re-circulate blood and dialysate circuits state
-
HD_PRE_TREATMENT_PATIENT_CONNECTION_STATE
-
Patient connection state
-
2
1
Qt::Horizontal
-
0
75
16777215
75
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
HD_Pre_Treatment_Sample_Water_States
Description
-
SAMPLE_WATER_SETUP_STATE
-
Sample water setup state of the sample water sub-mode state machine
-
SAMPLE_WATER_STATE
-
Sample water state of the sample water sub-mode state machine
-
0
155
16777215
155
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
2
3
4
5
HD_Pre_Treatment_Consumable_Self_Test_States
Description
-
CONSUMABLE_SELF_TESTS_INSTALL_STATE
-
Consumable self-tests install state
-
CONSUMABLE_SELF_TESTS_FILL_CMD_STATE
-
Send command to DG to fill reservoir state
-
CONSUMABLE_SELF_TESTS_WATER_QUALITY_CHECK_STATE
-
Consumable self-tests water quality check state
-
CONSUMABLE_SELF_TESTS_BICARB_PUMP_CHECK_STATE
-
Consumable self-tests bicarbonate concentrate pump check state
-
CONSUMABLE_SELF_TESTS_ACID_PUMP_CHECK_STATE
-
Consumable self-tests acid concentrate pump check state
-
CONSUMABLE_SELF_TESTS_COMPLETE_STATE
-
Consumable self-tests complete state
-
335
300
16777215
300
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
2
3
4
5
6
7
8
9
10
11
12
HD_Pre_Treatment_No_Cart_Self_Tests_States
Description
-
NO_CART_SELF_TESTS_START_STATE
-
No cartridge self-tests starting state.
-
NO_CART_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE
-
Wait for door to be closed before running self-tests.
-
NO_CART_SELF_TESTS_OCCLUSION_SENSORS_STATE
-
No cartridge occlusion sensors self-test state.
-
NO_CART_SELF_TESTS_BLOOD_FLOW_METERS_STATE
-
No cartridge blood flow meter self-test state.
-
NO_CART_SELF_TESTS_DIALYSATE_FLOW_METERS_STATE
-
No cartridge dialysate flow meter self-test state.
-
NO_CART_SELF_TESTS_PUMPS_STATE
-
No cartridge self-test for blood pump, dialysate in pump, dialysate out pump state.
-
NO_CART_SELF_TESTS_LEAK_DETECTORS_STATE
-
No cartridge leak detectors self-test state.
-
NO_CART_SELF_TESTS_BOARD_TEMPERATURE_STATE
-
No cartridge board temperature self-test state.
-
NO_CART_SELF_TESTS_DOOR_SWITCH_STATE
-
No cartridge door switch self-test state.
-
NO_CART_SELF_TESTS_HOME_VALVES_AND_PUMPS_STATE
-
No cartridge home valves and pumps self-test state.
-
NO_CART_SELF_TESTS_HOME_IDLE_STATE
-
Wait for valves and pumps finish homing state.
-
NO_CART_SELF_TESTS_STOPPED_STATE
-
No cart self-test stopped state.
-
NO_CART_SELF_TESTS_COMPLETE_STATE
-
No cartridge self-test complete state.
-
0
50
16777215
50
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
Installation State
Description
-
Installation State
-
Only one state
-
335
240
16777215
240
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
2
3
4
5
6
7
8
9
HD_Pre_Treatment_Dry_Self_Tests_States
Description
-
DRY_SELF_TESTS_START_STATE
-
Dry self-tests starting state.
-
DRY_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE
-
Wait for door to close before executing self-tests.
-
DRY_SELF_TESTS_BUBBLE_DETECTOR_STATE
-
Bubble detectors dry self-test state.
-
DRY_SELF_TESTS_AIR_TRAP_STATE
-
Air trap fill level ultrasonic sensor dry self-test state.
-
DRY_SELF_TESTS_OCCLUSION_SENSORS_STATE
-
Occlusion sensors dry self-test state.
-
DRY_SELF_TESTS_PRESSURE_SENSORS_SETUP_STATE
-
Pressure sensors dry self-test setup valves and pump state.
-
DRY_SELF_TESTS_PRESSURE_SENSORS_STATE
-
Pressure sensors verify pressure readings state.
-
DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_STATE
-
Preassure sensors verify normal pressure readings state.
-
DRY_SELF_TESTS_STOPPED_STATE
-
Dry self-test stopped state.
-
DRY_SELF_TESTS_COMPLETE_STATE
-
Dry self-test complete state.
-
335
280
16777215
280
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
2
3
4
5
6
7
8
9
10
11
HD_Pre_Treatment_Prime_States
Description
-
HD_PRIME_START_STATE
-
Prime start state
-
HD_PRIME_WAIT_FOR_USER_START_STATE
-
Wait for user to start prime state
-
HD_PRIME_SALINE_SETUP_STATE
-
Saline setup state
-
HD_PRIME_SALINE_PURGE_AIR_STATE
-
Saline purge air state
-
HD_PRIME_SALINE_CIRC_BLOOD_CIRCUIT_STATE
-
Circulate blood circuit state
-
HD_PRIME_RESERVOIR_ONE_FILL_COMPLETE_STATE
-
Wait for reservoir 1 fill complete
-
HD_PRIME_DIALYSATE_DIALYZER_STATE
-
Dialysate dialyzer fluid path state
-
HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE
-
Wait for reservoir 2 fill complete
-
HD_PRIME_DIALYSATE_BYPASS_STATE
-
Dialysate bypass fluid path state
-
HD_PRIME_WET_SELF_TESTS_STATE
-
Perform wet self-tests after priming complete
-
HD_PRIME_PAUSE
-
Prime pause state, waits to be resumed
-
HD_PRIME_COMPLETE
-
Prime complete state
-
335
75
16777215
75
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
1
HD_Pre_Treatment_Recirc_States
Description
-
PRE_TREATMENT_RECIRC_STATE
-
Pre-treatment recirculate state.
-
PRE_TREATMENT_RECIRC_STOPPED_STATE
-
Pre-treatment recirculate stopped state.
-
0
50
16777215
50
8
Qt::ScrollBarAlwaysOff
Qt::ScrollBarAlwaysOff
QAbstractItemView::NoEditTriggers
true
QAbstractItemView::SingleSelection
QAbstractItemView::SelectRows
false
2
true
350
true
21
00
Patient Connection State
Description
-
Patient Connection
-
Only one state
-
Qt::Vertical
20
40
tblSubMode
tblWaterSampleStates
tblConsumablesSelfTestStates
tblNoCartridgeSelfTestStates
tblInstallationStates
tblDrySelfTestStates
tblPrimeStates
tblRecirculateStates
tblPatientConnectionStates
scrollArea
tbReset