########################################################################### # # Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. # # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. # # @file strings.py # # @author (last) LTTS # @date (last) 18-Jan-2022 # ############################################################################ #standby mode BLOOD_PRIMING_TEXT = "Blood Priming" SALINE_UNIT = "mL" BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" # pretreatment_patient_connection DIASTOLIC_TEXT = "diastolic" SYSTOLIC_TEXT = "systolic" OUT_OF_RANGE_COLOR = "#c53b33" IN_RANGE_COLOR = "#fcfcfc" HEART_RATE_TITLE = "Heart Rate" BLOOD_PRESSURE_TITLE = "Blood Pressure" BLOOD_PRESSURE_UNIT = "mmHg" HEART_RATE_UNIT = "BPM" PATIENT_CONNECTION_TEXT = "Patient Connection" UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" UF_TITLE_TEXT = "Ultrafiltration Setup" BP_HR_TEXT = "BP/HR" SKIP_TEXT = "SKIP" TUTORIAL_TEXT = { 0 : "Wash your hands and establish vascular access per your clinic's instructions.", 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", 2 : "Remove arterial and venous shunt.", 3 : "Connect arterial and venous cartridge lines to your patient access lines." } PRE_TREATMENT_SCREENS = { 1 : "Create" , 2 : "Sample" , 3 : "Consumables" , 4 : "Disposables" , 5 : "Prime" , 6 : "Ultrafiltration" , 7 : "BP/HR" , 8 : "Connection" , 9 : "Start" } # dictionary of rejection reason from application source code. # message location -> denali-> Headers-> common-> MsgDefs.h REJECTION_REASON = { 0 : "REQUEST_REJECT_REASON_NONE" , # Used when there is no rejection 1 : "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE" , # "REQuest is not allowed in the current operating mode 2 : "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM" , # Validated "REQuest was not confirmed by user in reasonable time 3 : "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE" , # "REQuest is not allowed if not in treatment mode 4 : "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE" , # "REQuest is not allowed in current treatment state 5 : "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED" , # "REQuest is not allowed so near end of treatment 6 : "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE" , # Treatment duration is out of range 7 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT" , # Treatment time change is less than currently elapsed treatment time 8 : "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE" , # Blood flow is out of range 9 : "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE" , # Dialysate flow is out of range 10 : "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE" , # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit 11 : "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE" , # Ultrafiltration volume is out of range 12 : "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE" , # Ultrafiltration rate is out of range 13 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM" , # Treatment time change is less than minimum treatment time 14 : "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS" , # Ultrafiltration is not currently in progress 15 : "REQUEST_REJECT_REASON_UF_NOT_PAUSED" , # Ultrafiltration is not currently paused 16 : "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS" , # A saline bolus is in progress 17 : "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE" , # A treatment parameter is out of range 18 : "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION" , # The Heparin pre-stop setting is greater than the treatment duration 19 : "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH" , # Arterial pressure low and high alarm limits are not inconsistent 20 : "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH" , # Venous pressure low and high alarm limits are inconsistent 21 : "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED" , # Saline bolus volume maximum has been reached - no more saline allowed 22 : "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS" , # A saline bolus is not in progress 23 : "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE" , # "REQuested user action is disabled in current state 24 : "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE" , # "REQuested user action not allowed while alarm is active 25 : "REQUEST_REJECT_REASON_INVALID_COMMAND" , # "REQuested user action invalid 26 : "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED" , # The treatment has been completed 27 : "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED" , # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed 28 : "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET" , # Ultrafiltration volume is not set yet 29 : "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM" , # The user has not confirmed patient connection 30 : "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE" , # Heparin cannot be paused if not currently deliverying Heparin 31 : "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED" , # Heparin cannot be resumed if not paused 32 : "REQUEST_REJECT_REASON_DG_COMM_LOST" , # Treatment cannot initiate if DG comm is lost 33 : "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE" , # Post-treatment reservoirs drain not complete 34 : "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE" , # Treatment cannot initiate if DG is not in standby idle state 35 : "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT" , # "REQuest message not formatted properly 36 : "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME" , # Given date/time is invalid 37 : "REQUEST_REJECT_REASON_NO_NEW_TREATMENT_ALARM_TRIGGERED" , # Treatment cannot initiate if an alarm with no new treatment property has triggered before 38 : "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED" , # Battery does not have enough charge to start treatment 39 : "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED" , # Cannot move on to recirculate without completing full rinseback }