########################################################################### # # Copyright (c) 2021-2024 Diality Inc. - All Rights Reserved. # # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. # # @file dd_defs.py # # @author (last) Zoltan Miskolci # @date (last) 13-Jan-2026 # @author (original) Peter Lucia # @date (original) 22-Jun-2021 # ############################################################################ from enum import unique from aenum import extend_enum from typing import TYPE_CHECKING from .global_vars import GlobalVariables, test_config_change from ..utils.base import DialinEnum class DD_Defs: # IDE autocomplete support if TYPE_CHECKING: DDOpModes: DialinEnum DDFaultStates: DialinEnum DDFaultNVDataStates: DialinEnum DDServiceStates: DialinEnum DDInitStates: DialinEnum DDStandbyStates: DialinEnum DDPreGenDialysateStates: DialinEnum DDGenDialysateModeStates: DialinEnum DDPostGenDialysateStates: DialinEnum DDHeatDisinfectStates: DialinEnum DDHeaterCoolingStates: DialinEnum DDROPermeateStates: DialinEnum DDNotLegalStates: DialinEnum DDEventList: DialinEnum DDEventDataTypes: DialinEnum DDConcentratePumpNames:DialinEnum DDConductivitySensorNames:DialinEnum DDDialysatePumpNames:DialinEnum DDHeaterNames:DialinEnum DDLevelSensorNames:DialinEnum DDPistonPumpNames:DialinEnum DDPressureSensorNames:DialinEnum DDTemperatureSensorNames: DialinEnum DDValveNames: DialinEnum DDMonitoredVoltages: DialinEnum DDBalancingChamberStates:DialinEnum DDBalancingChamberSwitchStates:DialinEnum DDBloodLeakStates:DialinEnum DDConcentratePumpAttributes:DialinEnum DDConcentratePumpStates:DialinEnum DDDialysatePumpAttributes:DialinEnum DDDialysatePumpsStates:DialinEnum DDHeaterStartStop:DialinEnum DDHeaterAttributes:DialinEnum DDHeaterExecState:DialinEnum DDPistonPumpAttributes:DialinEnum DDValveStates: DialinEnum _properties = { # Operation / State enums 'DDOpModes': '_create_dd_operation_modes', 'DDFaultStates': '_create_dd_fault_states', 'DDFaultNVDataStates': '_create_dd_fault_nvdata_states', 'DDServiceStates': '_create_dd_service_states', 'DDInitStates': '_create_dd_init_states', 'DDStandbyStates': '_create_dd_standby_states', 'DDPreGenDialysateStates': '_create_dd_pregen_states', 'DDGenDialysateModeStates': '_create_dd_gen_states', 'DDPostGenDialysateStates': '_create_dd_postgen_states', 'DDHeatDisinfectStates': '_create_dd_heat_disinfect_states', 'DDHeaterCoolingStates': '_create_dd_heater_cooling_states', 'DDROPermeateStates': '_create_dd_ro_permeate_states', 'DDNotLegalStates': '_create_dd_not_legal_states', # Event enums 'DDEventList': '_create_dd_event_list', 'DDEventDataTypes': '_create_dd_event_data_types', # Module Names enums 'DDConcentratePumpNames': '_create_dd_concentrate_pump_names', 'DDConductivitySensorNames': '_create_dd_conductivity_sensor_names', 'DDDialysatePumpNames': '_create_dd_dialysate_pump_names', 'DDHeaterNames': '_create_dd_heater_names', 'DDLevelSensorNames': '_create_dd_level_sensor_names', 'DDPistonPumpNames': '_create_dd_piston_pump_names', 'DDPressureSensorNames': '_create_dd_pressure_sensor_names', 'DDTemperatureSensorNames': '_create_dd_temperature_sensor_names', 'DDValveNames': '_create_dd_valve_names', 'DDMonitoredVoltages': '_create_dd_monitored_voltages', # Support enums 'DDBalancingChamberStates': '_create_dd_balancing_chamber_states', 'DDBalancingChamberSwitchStates': '_create_dd_balancing_chamber_switch_states', 'DDBloodLeakStates': '_create_dd_blood_leak_states', 'DDConcentratePumpAttributes': '_create_dd_concentrate_pump_attributes', 'DDConcentratePumpStates': '_create_dd_concentrate_pump_states', 'DDDialysatePumpAttributes': '_create_dd_dialysate_pump_attributes', 'DDDialysatePumpsStates': '_create_dd_dialysate_pump_states', 'DDHeaterStartStop': '_create_dd_heater_start_stop', 'DDHeaterAttributes': '_create_dd_heater_attributes', 'DDHeaterExecState': '_create_dd_heater_exec_states', 'DDPistonPumpAttributes': '_create_dd_piston_pump_attributes', 'DDValveStates': '_create_dd_valve_states', } def __init__(self): self.update_enums() def __getattr__(self, name) -> DialinEnum: if name in self._properties: enum = getattr(self, self._properties[name])() setattr(self, name, enum) return enum raise AttributeError(name) def update_enums(self) -> None: for prop_name in self._properties: # Cleans the cached value self.__dict__.pop(prop_name, None) # Reinitializing the enum as it's not in the cache self.__getattr__(prop_name) # ================================================== Enum Creators: Operations ================================================== def _create_dd_operation_modes(self): members = { 'MODE_FAUL': 0, # Fault Mode 'MODE_SERV': 1, # Service Mode 'MODE_INIT': 2, # Initialization & POST Mode 'MODE_STAN': 3, # Standby Mode 'MODE_PREG': 4, # Pre-generate Dialysate Mode 'MODE_GEND': 5, # Generate Dialysate Mode 'MODE_POSG': 6, # Post-generate Dialysate Mode 'MODE_HEAT': 7, # Heat Disinfect Mode 'MODE_HCOL': 8, # Cooling Mode 'MODE_ROPS': 9, # RO Permeate Sample Mode 'MODE_NLEG': 10, # Non-legal Mode - an illegitimate mode transition has occurred 'NUM_OF_DD_MODES': 11, # Number of Modes for the DD } return unique(DialinEnum('DDOpModes', members)) def _create_dd_fault_states(self): members = { 'DD_FAULT_STATE_START': 0, # DD fault start state 'DD_FAULT_DEENERGIZED_STATE': 1, # DD fault de-energized state 'DD_FAULT_ENERGIZED_STATE': 2, # DD fault energized state 'NUM_OF_DD_FAULT_STATES': 3, # Number of fault mode states } return unique(DialinEnum('DDFaultStates', members)) def _create_dd_fault_nvdata_states(self): members = { 'DD_FAULT_STATE_START': 0, # DD fault start state 'DD_FAULT_STATE_RUN_NV_POSTS': 1, # DD fault run RTC and NV data management post 'DD_FAULT_STATE_COMPLETE': 2, # DD fault complete 'NUM_OF_DD_FAULT_NVDATA_STATES': 3, # Number of fault mode NV Data management states } return unique(DialinEnum('DDFaultNVDataStates', members)) def _create_dd_service_states(self): members = { 'DD_SERVICE_STATE_START': 0, # Start service mode state 'NUM_OF_DD_SERVICE_STATES': 1, # Number of service mode states } return unique(DialinEnum('DDServiceStates', members)) def _create_dd_init_states(self): members = { 'DD_POST_STATE_START': 0, # Post Generate Dialysate Start State 'DD_POST_STATE_FW_COMPATIBILITY': 1, # Firmware Compatibility State 'DD_POST_STATE_FW_INTEGRITY': 2, # Firmware Integrity State 'DD_POST_STATE_FPGA': 3, # FPGA State 'DD_POST_STATE_NVDATAMGMT': 4, # Non-volatile Data Management State 'DD_POST_STATE_TEMPERATURE_SENSORS': 5, # Temperature Sensors State 'DD_POST_STATE_PRESSURES': 6, # Pressure Sensors State 'DD_POST_STATE_DIALYSATE_PUMPS': 7, # Dialysate Pumps State 'DD_POST_STATE_CONCENTRATE_PUMPS': 8, # Concentrate Pumps State 'DD_POST_STATE_CONDUCTIVITY_SENSORS': 9, # Conductivity Sensors State 'DD_POST_STATE_WATCHDOG': 10, # Watchdog State 'DD_POST_STATE_SAFETY_SHUTDOWN': 11, # Safety Shutdown State 'DD_POST_STATE_COMPLETED': 12, # Post Generate Dialysate Completed State 'DD_POST_STATE_FAILED': 13, # Post Generate Dialysate Fail State 'NUM_OF_DD_POST_STATES': 14, # Number of Post Generate Dialysate States } return unique(DialinEnum('DDInitStates', members)) def _create_dd_standby_states(self): members = { 'DD_STANDBY_MODE_STATE_IDLE': 0, # Idle standby mode state 'DD_STANDBY_MODE_STATE_PAUSE': 1, # Pause state 'NUM_OF_DD_STANDBY_MODE_STATES': 2, # Number of standby mode states } return unique(DialinEnum('DDStandbyStates', members)) def _create_dd_pregen_states(self): members = { 'DD_PRE_GEN_DIALYSATE_HYD_CHAMBER_FILL_CHECK': 0, # DD Pre-Gen Dialysate hyrochamber fill check 'DD_PRE_GEN_WET_SELF_TEST': 1, # DD Pre-Gen Wet Self Test 'DD_PRE_GEN_DIALYSATE_WAIT_FOR_GEND': 2, # DD Pre-Gen Dialysate Wait for Gen Dialysate state transition 'NUM_OF_DD_PRE_GEN_DIALYSATE_STATES': 3, # Number of Pre-Gen Dialysate mode states } return unique(DialinEnum('DDPreGenDialysateStates', members)) def _create_dd_gen_states(self): members = { 'DD_GEND_STATE_START': 0, # Gen dialysate start state 'DD_GEND_DIALYSATE_BYPASS_STATE': 1, # Gen dialysate - Bypass dialysate state 'DD_GEND_DIALYSATE_DELIVERY_STATE': 2, # Gen dialysate - deliver dialysate state 'DD_GEND_ISOLATED_UF_STATE': 3, # Gen dialysate - Isolated ultrafiltration state 'DD_GEND_SPENT_CHAMBER_FILL_STATE': 4, # Gen dialysate - spent chamber fill state 'DD_GEND_BICARB_CHAMBER_FILL_STATE': 5, # Gen dialysate - bicarb chamber fill state 'DD_GEND_DIALYSATE_DELIVERY_PAUSE': 6, # Gen dialysate - dialysate delivery pause state 'NUM_OF_DD_GEND_MODE_STATES': 7, # Number of gen dialysate states } return unique(DialinEnum('DDGenDialysateModeStates', members)) def _create_dd_postgen_states(self): members = { 'DD_POST_GEN_DIALYSATE_STATE_START': 0, # DD Post-Gen Dialysate state start 'DD_POST_GEN_DIALYSATE_STATE_COMPLETE': 1, # DD Post-Gen Dialysate complete state 'NUM_OF_DD_POST_GEN_DIALYSATE_STATES': 2, # Number of Post-Gen Dialysate mode states } return unique(DialinEnum('DDPostGenDialysateStates', members)) def _create_dd_heat_disinfect_states(self): members = { 'DD_HEAT_DISINFECT_STATE_START': 0, # Heat disinfect, start mode state 'DD_HEAT_DISINFECT_STATE_COMPLETE': 1, # Heat disinfect, complete state 'NUM_OF_DD_HEAT_DISINFECT_STATES': 2 # Number of heat disinfect mode states } return unique(DialinEnum('DDHeatDisinfectStates', members)) def _create_dd_heater_cooling_states(self): members = { 'NUM_OF_DD_HEAT_COOL_STATES': 0, # Number of Heater Cooling states } return unique(DialinEnum('DDHeaterCoolingStates', members)) def _create_dd_ro_permeate_states(self): members = { 'NUM_OF_RO_PERMEATE_STATES': 0, # Number of RO Permeate states } return unique(DialinEnum('DDROPermeateStates', members)) def _create_dd_not_legal_states(self): members = { 'NUM_OF_NOT_LEGAL_STATES': 0, # Number of Not Legal states } return unique(DialinEnum('DDNotLegalStates', members)) def _create_dd_event_list(self): members = { 'DD_EVENT_STARTUP': 0, # DD startup event 'DD_EVENT_OP_MODE_CHANGE': 1, # DD Op mode change event 'DD_EVENT_SUB_MODE_CHANGE': 2, # DD Op sub-mode change event 'DD_EVENT_OPERATION_STATUS': 3, # DD operation status event 'DD_EVENT_D6_LEVL_CHANGE': 4, # DD floater level change event 'DD_EVENT_D63_LEVL_CHANGE': 5, # DD bicarb level change event 'DD_EVENT_D46_LEVL_CHANGE': 6, # DD spent dialysate air seperation level change event 'DD_EVENT_TD_COMMUNICATION_LOSS': 7, # DD TD communication loss 'DD_EVENT_TEMPERATURE_DRIFT': 8, # DD dialysate temperature drift 'DD_EVENT_BLOOD_LEAK_ZEROING_REQUEST': 9, # DD blood leak zeroing request 'DD_EVENT_BLOOD_LEAK_ZEROING_REQUIRED': 10, # DD blood leak zeroing required 'DD_EVENT_BLOOD_LEAK_NUM_OF_SET_POINT_CHECK_FAILURES': 11, # DD blood leak number of setpoint check failures 'DD_EVENT_BLOOD_LEAK_SELF_TEST_RESULT': 12, # DD blood leak self test result 'NUM_OF_DD_EVENT_IDS': 13, # Total number of DD events } return unique(DialinEnum('DDEventList', members)) def _create_dd_event_data_types(self): members = { 'EVENT_DATA_TYPE_NONE': 0, # No Event Data Type 'EVENT_DATA_TYPE_U32': 1, # Unsigned 32bit Event Data Type 'EVENT_DATA_TYPE_S32': 2, # Signed 32bit Event Data Type 'EVENT_DATA_TYPE_F32': 3, # Float 32bit Event Data Type 'EVENT_DATA_TYPE_BOOL': 4, # Boolean Event Data Type 'NUM_OF_EVENT_DATA_TYPES': 5, # Number of Event Data Types } return unique(DialinEnum('DDEventDataTypes', members)) # ================================================== Enum Creators: Names ================================================== def _create_dd_concentrate_pump_names(self): members = { 'D11_CP1_ACID': 0, # Acid Concentrate Pump 'D10_CP2_BICARB': 1, # Bicarbonate Concentrate Pump 'D76_UF': 2, # Ultrafiltration Concentrate Pump 'NUM_OF_CONCENTRATE_PUMPS': 3, # Number of Concentrate Pumps } return unique(DialinEnum('DDConcentratePumpNames', members)) def _create_dd_conductivity_sensor_names(self): members = { 'D17_COND': 0, # Closed Loop Control of Dosing for D74 Conductivity Sensor 'D27_COND': 1, # Closed Loop Control of Dosing for D29 Conductivity Sensor 'D29_COND': 2, # Water, Bicarbonate, and Acid Collective Conductivity Sensor 'D43_COND': 3, # Self Test Conductivity Sensor (not used for dialysate conductivity) 'D74_COND': 4, # Water and Bicarbonate Collective Conductivity Sensor 'NUM_OF_CONDUCTIVITY_SENSORS': 5 # Number of Conductivity Sensors } return unique(DialinEnum('DDConductivitySensorNames', members)) def _create_dd_dialysate_pump_names(self): members = { 'D12_PUMP': 0, # Fresh Dialysate Pump 'D48_PUMP': 1, # Spent Dialysate Pump 'NUM_OF_DIALYSATE_PUMPS': 2, # Number of Dialysate Pumps } return unique(DialinEnum('DDDialysatePumpNames', members)) def _create_dd_heater_names(self): members = { 'D5_HEAT': 0, # Primary heater 'D45_HEAT': 1, # Trimmer heater 'NUM_OF_DD_HEATERS': 2, # Number of Heaters } return unique(DialinEnum('DDHeaterNames', members)) def _create_dd_level_sensor_names(self): if GlobalVariables().HW_BETA_1_9 == True: members = { 'D6_LEVEL': 0, # floater switch low, medium and high status 'D63_LEVEL': 1, # bicarb level low or high status 'D46_LEVEL': 2, # Spent dialysate air separation chamber level low or high status 'D98_LEVEL': 3, # D98 Conductivity Level Sensor 'NUM_OF_LEVELS': 4, # Number of Level Sensors } else: members = { 'D6_LEVEL': 0, # floater switch low, medium and high status 'D63_LEVEL': 1, # bicarb level low or high status 'D46_LEVEL': 2, # Spent dialysate air separation chamber level low or high status 'NUM_OF_LEVELS': 3, # Number of Level Sensors } return unique(DialinEnum('DDLevelSensorNames', members)) def _create_dd_piston_pump_names(self): members = { 'ACID': 0, # Acid piston pump 'BICARB': 1, # Bicarbonate piston pump 'UF': 2, # Ultrafiltration piston pump 'NUM_OF_PISTON_PUMPS': 3, # Number of piston pumps } return unique(DialinEnum('DDPistonPumpNames', members)) def _create_dd_pressure_sensor_names(self): if GlobalVariables().HW_BETA_1_9 == True: members = { 'D9_PRES': 0, # Hydraulics outlet pressure (PHo/Pn) 'D66_PRES': 1, # Dry Bicarb pressure (PDB/PCb) 'D51_PRES': 2, # Spent Dialysate pressure (PDs) 'D18_PRES': 3, # Fresh Dialysate pressure (PDf) 'D41_PRES': 4, # Transmembrane pressure (Ptm) 'D87_PRES': 5, # D87 Pressure Sensor 'NUM_OF_PRESSURE_SENSORS': 6, # Number of pressure sensors } else: members = { 'D9_PRES': 0, # Hydraulics outlet pressure (PHo/Pn) 'D66_PRES': 1, # Dry Bicarb pressure (PDB/PCb) 'D51_PRES': 2, # Spent Dialysate pressure (PDs) 'D18_PRES': 3, # Fresh Dialysate pressure (PDf) 'D41_PRES': 4, # Transmembrane pressure (Ptm) 'NUM_OF_PRESSURE_SENSORS': 5, # Number of pressure sensors } return unique(DialinEnum('DDPressureSensorNames', members)) def _create_dd_temperature_sensor_names(self): if GlobalVariables().HW_BETA_1_9 == True: members = { 'D1_TEMP': 0, # Heat exchanger Inlet temperature sensor 'D78_TEMP': 1, # Heat exchanger Outlet temperature sensor 'D4_TEMP': 2, # Hydraulics primary heater temperature sensor 'D50_TEMP': 3, # Trimmer heater temperature sensor 'BRD_TEMP': 4, # Barometric temperature sensor 'D16_TEMP': 5, # D16(D17) Conductivity sensor temperature value 'D28_TEMP': 6, # D28(D27) Conductivity sensor temperature value 'D30_TEMP': 7, # D30(D29) Conductivity sensor temperature value 'D44_TEMP': 8, # D44(D43) Conductivity sensor temperature value 'D75_TEMP': 9, # D75(D74) Conductivity sensor temperature value 'D99_TEMP': 10, # D98(D99) Conductivity sensor temperature value 'D4_AVG_TEMP': 11, # D4 Filtered value 'D50_AVG_TEMP': 12, # D50 Filtered value 'D28_AVG_TEMP': 13, # D28 Filtered value 'D30_AVG_TEMP': 14, # D30 Filtered value 'D99_AVG_TEMP': 15, # D99 Filtered value 'D9_TEMP': 16, # D9 Pressure sensor temperature value 'D66_TEMP': 17, # D66 Pressure sensor temperature value 'D51_TEMP': 18, # D51 Pressure sensor temperature value 'D18_TEMP': 19, # D18 Pressure sensor temperature value 'D41_TEMP': 20, # D41 Pressure sensor temperature value 'D87_TEMP': 21, # D87 Pressure sensor temperature value 'NUM_OF_TEMP_SENSORS': 22, # Number of Temperature Sensors } else: members = { 'D1_TEMP': 0, # Heat exchanger Inlet temperature sensor 'D78_TEMP': 1, # Heat exchanger Outlet temperature sensor 'D4_TEMP': 2, # Hydraulics primary heater temperature sensor 'D50_TEMP': 3, # Trimmer heater temperature sensor 'BRD_TEMP': 4, # Barometric temperature sensor 'D16_TEMP': 5, # D16(D17) Conductivity sensor temperature value 'D28_TEMP': 6, # D28(D27) Conductivity sensor temperature value 'D30_TEMP': 7, # D30(D29) Conductivity sensor temperature value 'D44_TEMP': 8, # D44(D43) Conductivity sensor temperature value 'D75_TEMP': 9, # D75(D74) Conductivity sensor temperature value 'D4_AVG_TEMP': 10, # D4 Filtered value 'D50_AVG_TEMP': 11, # D50 Filtered value 'D28_AVG_TEMP': 12, # D28 Filtered value 'D30_AVG_TEMP': 13, # D30 Filtered value 'D9_TEMP': 14, # D9 Pressure sensor temperature value 'D66_TEMP': 15, # D66 Pressure sensor temperature value 'D51_TEMP': 16, # D51 Pressure sensor temperature value 'D18_TEMP': 17, # D18 Pressure sensor temperature value 'D41_TEMP': 18, # D41 Pressure sensor temperature value 'NUM_OF_TEMP_SENSORS': 19, # Number of Temperature Sensors } created_enum = DialinEnum('DDTemperatureSensorNames', members) # Add aliases extend_enum(created_enum, 'FIRST_PRESSURE_SENSOR', created_enum.D9_TEMP.value) extend_enum(created_enum, 'LAST_PRESSURE_SENSOR', created_enum.D87_TEMP.value if GlobalVariables().HW_BETA_1_9 == True else created_enum.D41_TEMP.value) extend_enum(created_enum, 'FIRST_CONDUCTIVITY_SENSOR', created_enum.D16_TEMP.value) extend_enum(created_enum, 'LAST_CONDUCTIVITY_SENSOR', created_enum.D75_TEMP.value) extend_enum(created_enum, 'FIRST_AVERAGE_SENSOR', created_enum.D4_AVG_TEMP.value) extend_enum(created_enum, 'LAST_AVR_CONDUCTIVITY_SENSOR', created_enum.D30_AVG_TEMP.value) # Add aliases to be searchable (listed when pressed TAB) created_enum._member_names_.append('FIRST_PRESSURE_SENSOR') created_enum._member_names_.append('LAST_PRESSURE_SENSOR') created_enum._member_names_.append('FIRST_CONDUCTIVITY_SENSOR') created_enum._member_names_.append('LAST_CONDUCTIVITY_SENSOR') created_enum._member_names_.append('FIRST_AVR_CONDUCTIVITY_SENSOR') created_enum._member_names_.append('LAST_AVR_CONDUCTIVITY_SENSOR') return created_enum def _create_dd_valve_names(self): members = { 'D14_VALV': 0, # Valve Hydraulics Outlet (D14) 'D52_VALV': 1, # Valve Thermal Disinfect (D52) 'D8_VALV': 2, # Valve Hydraulics Bypass (D8) 'D54_VALV': 3, # Valve Rinse Port (D54) 'D53_VALV': 4, # Valve Drain (D53) 'D34_VALV': 5, # Valve Dialyzer Bypass (D34) 'D64_VALV': 6, # Valve Purge 1 (D64) 'D31_VALV': 7, # Valve Pressure Test (D31) 'D65_VALV': 8, # Valve DryBcarb Inlet (D65) 'D35_VALV': 9, # Valve Dialyzer Inlet (D35) 'D40_VALV': 10, # Valve Dialyzer Outlet (D40) 'D47_VALV': 11, # Valve Dialysate Out Purge 2 (D47) 'D3_VALV': 12, # Valve Hydraulics Inlet (D3) 'D80_VALV': 13, # Valve Dry Bicarb (D80) 'D81_VALV': 14, # Valve De-scaler (D81) 'D85_VALV': 15, # Valve De-scaler (D85) 'D23_VALV': 16, # Balancing chamber Valve 1 (D23) 'D19_VALV': 17, # Balancing chamber Valve 2 (D19) 'D25_VALV': 18, # Balancing chamber Valve 3 (D25) 'D21_VALV': 19, # Balancing chamber Valve 4 (D21) 'D24_VALV': 20, # Balancing chamber Valve 5 (D24) 'D20_VALV': 21, # Balancing chamber Valve 6 (D20) 'D26_VALV': 22, # Balancing chamber Valve 7 (D26) 'D22_VALV': 23, # Balancing chamber Valve 8 (D22) 'D79_PMP_VALV': 24, # D79 pump mapped to Spare Valve 0 'D83_VALV': 25, # D83 De-scaler Valve mapped to Spare Valve 1 'D91_VALV': 26, # D91 De-scaler Valve mapped to Spare Valve 2 'SPARE3_VALV': 27, # Spare Valve 3 'SPARE4_VALV': 28, # Spare Valve 4 'SPARE5_VALV': 29, # Spare Valve 5 'D100_VALV': 30, # D100 De-scaler Valve mapped to Spare Valve 6 'SPARE7_VALV': 31, # Spare Valve 7 'NUM_OF_DD_VALVES': 32, # Number of Valves for the DD } return unique(DialinEnum('DDValveNames', members)) def _create_dd_monitored_voltages(self): members = { 'MONITORED_LINE_1_2V': 0, # Processor voltage (1.2V) 'MONITORED_LINE_3_3V': 1, # Logic voltage (3.3V) 'MONITORED_LINE_5V_LOGIC': 2, # Logic voltage (5V) 'MONITORED_LINE_24V_1': 3, # Actuators voltage (24V) 'MONITORED_LINE_24V_2': 4, # Actuators regen voltage (24V) 'MONITORED_LINE_FPGA_VCC_V': 5, # FPGA Vcc (3V) 'MONITORED_LINE_FPGA_AUX_V': 6, # FPGA Vaux (3V) 'MONITORED_LINE_FPGA_PVN_V': 7, # FPGA Vpvn (1V) 'NUM_OF_MONITORED_VOLTAGE_LINES': 8, # Number of TD operation modes } return unique(DialinEnum('DDMonitoredVoltages', members)) # ================================================== Enum Creators: Support ================================================== def _create_dd_balancing_chamber_states(self): members = { 'BAL_CHAMBER_STATE_START': 0, # Initial state of balancing chamber 'BAL_CHAMBER_STATE1_FILL_START': 1, # Balancing chamber state 1 fill start state 'BAL_CHAMBER_STATE1_BICARB_ACID_DOSING_CNTRL': 2, # Balancing Chamber state 1 Bicarb and acid dosing control state 'BAL_CHAMBER_STATE1_FILL_END': 3, # Balancing Chamber state 1 fill end state 'BAL_CHAMBER_STATE2_FILL_START': 4, # Balancing chamber state 2 fill start state 'BAL_CHAMBER_STATE2_BICARB_ACID_DOSING_CNTRL': 5, # Balancing Chamber state 2 Bicarb and acid dosing control state 'BAL_CHAMBER_STATE2_FILL_END': 6, # Balancing Chamber state 2 fill end state 'NUM_OF_BAL_CHAMBER_EXEC_STATES': 7, # Number of balancing chamber states } return unique(DialinEnum('DDBalancingChamberStates', members)) def _create_dd_balancing_chamber_switch_states(self): members = { 'BAL_CHAMBER_SW_STATE1': 0, # Balancing chamber switching state 1 (V2,V5 and V3, V8 open, rest closed) 'BAL_CHAMBER_SW_STATE2': 1, # Balancing chamber switching state 2 ( V1,V6 and V4, V7 open, rest closed) 'NUM_OF_BAL_CHAMBER_SW': 2, # Number of balancing chamber states } return unique(DialinEnum('DDBalancingChamberSwitchStates', members)) def _create_dd_blood_leak_states(self): members = { 'BLOOD_LEAK_WAIT_FOR_POST_STATE': 0, # 'BLOOD_LEAK_CHECK_SET_POINT_STATE': 1, # 'BLOOD_LEAK_INIT_STATE': 2, # 'BLOOD_LEAK_CHECK_ZERO_AND_SELF_TEST_STATE': 3, # 'BLOOD_LEAK_VERIFY_INTENSITY_AFTER_ZEROING_STATE': 4, # 'BLOOD_LEAK_NORMAL_STATE': 5, # 'BLOOD_LEAK_RECOVER_BLOOD_DETECT_STATE': 6, # 'NUM_OF_BLOOD_LEAK_STATES': 7, # Number of blood leak states } return unique(DialinEnum('DDBloodLeakStates', members)) def _create_dd_concentrate_pump_attributes(self): members = { 'CURRENT_STATE': 0, # Current State Concentrate Pump Attribute 'CURRENT_SET_SPEED': 1, # Current Set Speed Concentrate Pump Attribute 'MEASURED_SPEED': 2, # Measured Speed Concentrate Pump Attribute 'TARGET_SPEED': 3, # Target Speed Concentrate Pump Attribute 'PULSE_US': 4, # Hall Sensor Pulse Width (in micro seconds) Concentrate Pump Attribute 'TARGET_REV_COUNT': 5, # Target Revolutions Concentrate Pump Attribute 'MEASURED_REV_COUNT': 6, # Measured Revolutions Concentrate Pump Attribute 'PARKED': 7, # Parked Concentrate Pump Attribute 'PARK_FAULT': 8, # Park Fault Concentrate Pump Attribute 'NUM_OF_D10_D11_CONCENTRATE_PUMP_ATTRIBUTES': 9, # Number of Acid (D11) and Bicarbonate (D10) Concentrate Pump Attributes } return unique(DialinEnum('DDConcentratePumpAttributes', members)) def _create_dd_concentrate_pump_states(self): members = { 'CONCENTRATE_PUMP_OFF_STATE': 0, # Concentrate Pump Off State 'CONCENTRATE_PUMP_RAMP_TO_TARGET_SPEED_STATE': 1, # Ramp to Target Speed Concentrate Pump State 'CONCENTRATE_PUMP_CONTROL_TARGET_SPEED_STATE': 2, # Control Target Speed Concentrate Pump State 'NUM_OF_CONCENTRATE_PUMP_STATES': 3, # Number of Concentrate Pump States } return unique(DialinEnum('DDConcentratePumpStates', members)) def _create_dd_dialysate_pump_attributes(self): members = { 'TARGET_RPM': 0, # Target RPM Dialysate Pump Attribute 'MEASURED_SPEED': 1, # Measured Speed Dialysate Pump Attribute 'CURRENT_SPEED': 2, # Current Speed Dialysate Pump Attribute 'STATE': 3, # State to command Dialysate Pump Attribute 'TARGET_PRESSURE': 4, # Target Pressure Dialysate Pump Attribute 'MEASURED_PRESSURE': 5, # Measured Pressure Dialysate Pump Attribute 'MEASURED_CURRENT': 6, # Measured Current Dialysate Pump Attribute 'CONTROL': 7, # Pump Run/Stop Control Pump Attribute 'DIRECTION_ERROR_COUNT': 8, # Direction Error Count Dialysate Pump Attribute 'MEASURED_DIRECTION': 9, # Measured Direction Dialysate Pump Attribute 'NUM_OF_DIALYSATE_PUMP_ATTRIBUTES': 10, # Number of Dialysate Pump Attributes } return unique(DialinEnum('DDDialysatePumpAttributes', members)) def _create_dd_dialysate_pump_states(self): members = { 'DIALYSATE_PUMP_OFF_STATE': 0, # Dialysate Pump Off State 'DIALYSATE_PUMP_RAMP_UP_STATE': 1, # Dialysate Pump Ramp Up State 'DIALYSATE_PUMP_CONTROL_TO_TARGET_STATE': 2, # Dialysate Pump Control to Target State 'NUM_OF_DIALYSATE_PUMP_STATES': 3, # Number of Dialysate Pump States } return unique(DialinEnum('DDDialysatePumpsStates', members)) def _create_dd_heater_start_stop(self): return unique(DialinEnum('DDHeaterStartStop', {'STOP': 0, 'START': 1})) def _create_dd_heater_attributes(self): members = { 'HEAT_DUTY_CYCLE': 0, # Heat Duty Cycle Attribute for Heaters 'HEAT_TARGET_TEMP': 1, # Target Temperature Attribute for Heaters 'HEAT_STATE': 2, # State to command Attribute for Heaters 'DUTY_CYCLE_COUNT': 3, # Duty Cycle Count Attribute for Heaters 'PWM_PERIOD': 4, # Pulse Width Modulation Attribute for Heaters 'ADJUSTED_TARGET_TEMP': 5, # Adjusted Target Temperature Attribute for Heaters 'TARGET_TEMP_TD': 6, # Target Temperature Attribute for Heaters 'NUM_OF_DD_HEATER_ATTRIBUTES': 7, # Number of Heater Attributes } return unique(DialinEnum('DDHeaterAttributes', members)) def _create_dd_heater_exec_states(self): members = { 'HEATER_EXEC_STATE_OFF': 0, # Heater Execution Off State 'HEATER_EXEC_STATE_RAMP_TO_TARGET': 1, # Heater Execution Ramp to Target State 'HEATER_EXEC_STATE_CONTROL_TO_TARGET': 2, # Heater Execution Control to Target State 'HEATER_EXEC_STATE_CONTROL_TO_DISINFECT_TARGET': 3, # Heater Execution Control to Disinfection State 'NUM_OF_HEATERS_EXEC_STATE': 4, # Number of Heater Execution States } return unique(DialinEnum('DDHeaterExecState', members)) def _create_dd_piston_pump_attributes(self): members = { 'CONTROL_STATE': 0, # Control State for the Piston Pumps 'SW_COUNTER': 1, # Software counter attribute for the Piston Pumps 'CYCLE_COUNTER': 2, # Cycle Counter for the Piston Pumps 'NUM_OF_PISTON_PUMP_ATTRIBUTES': 3, # Number of Piston Pump Attributes } return unique(DialinEnum('DDPistonPumpAttributes', members)) def _create_dd_valve_states(self): members = { 'VALVE_STATE_CLOSED': 0, # Valve Closed State 'VALVE_STATE_OPEN': 1, # Valve Open State } return unique(DialinEnum('DDValveStates', members)) # ================================================== Creates a singleton ================================================== dd_enum_repository = DD_Defs() # Attach listener to update function test_config_change.add_listener(dd_enum_repository.update_enums)